1,317 research outputs found

    Separation of random telegraph signals from 1/f noise in MOSFETs under constant and switched bias conditions

    Get PDF
    The low-frequency noise power spectrum of small dimension MOSFETs is dominated by Lorentzians arising from random telegraph signals (RTS). The low-frequency noise is observed to decrease when the devices are periodically switched 'off'. The technique of determining the statistical lifetimes and amplitudes of the RTS by fitting the signal level histogram of the time-domain record to two-Gaussian histograms has been reported in the literature. This procedure is then used for analysing the 'noisy' RTS along with the device background noise, which turned out to be 1/f noise. The 1/f noise of the device can then be separated from the RTS using this procedure. In this work, RTS observed in MOSFETs, under both constant and switched biased conditions, have been investigated in the time domain, Further, the 1/f noise in both the constant and the switched biased conditions is investigated

    Degradation of AB25 dye in liquid medium by atmospheric pressure non-thermal plasma and plasma combination with photocatalyst TiO2

    Get PDF
    In this work, degradation of the anthraquinonic dye Acid Blue 25 by non-thermal plasma at atmospheric pressure with and without photocatalyst is investigated. Titanium dioxide (TiO2) is used as a photocatalyst. The dye degradation by plasma in the presence of TiO2 is investigated as a function of TiO2 concentration, dye concentration and pH. The degradation rate is higher in acidic solutions with pH of 2 to 4.3, especially at pH 2, and decreases to 0.38 mg L-1 min(-1) with the increase of pH from 2 to 5.65. A similar effect is observed in basic media, where a higher degradation rate is found at pH = 10.3. The degradation rate increases in the presence of TiO2 compared to the discharge without photocatalysis. The results show that the degradation of the dye increases in the presence of TiO2 until the catalyst load reaches 0.5 g L-1 after which the suppression of AB25 degradation is observed. The results indicate that the tested advanced oxidation processes are very effective for the degradation of AB25 in aqueous solutions

    Effectiveness of implant-supported fixed partial denture in patients with history of periodontitis: A systematic review and meta-analysis

    Get PDF
    Aim: This systematic review investigates the effectiveness of implant-supported fixed partial denture (IS-FPD) in patients with history of periodontitis (HP) vs. patients with no history of periodontitis (NHP). Methods: A literature search was performed on different databases on May 2020. Prospective and retrospective studies assessing survival (primary outcome), success and biological/mechanical complications of IS-FPDs in HP vs. NHP patients at ≥1 year after implant loading were evaluated. Meta-analyses were conducted by estimating hazard ratio (HR), risk ratio (RR) and standardized mean differences (SMD) with 95% confidence intervals (CI) using random effect models. Results: Of the initially identified 4096 articles, 349 underwent a full-text evaluation. Finally, 17 were included. Pooled data analyses showed that overall implant survival was significantly higher in the NHP than the HP group (HR = 2.06; 95% CI = 1.37–3.09; I2 = 0%). This difference was noted when follow-up ≥5 years. The risk of peri-implantitis was higher in HP than NHP patients (RR = 3.3; 95% CI = 1.31–8.3; I2 = 0%), whereas the mean marginal bone level change over time was not different between the groups (SMD = âˆ’0.16 mm; 95% CI = âˆ’1.04–0.73; I2 = 98%). Conclusions: In partially edentulous patients receiving IS-FPDs, a history of periodontitis is associated with poorer survival rate and higher risk of peri-implantitis during a 5–10 years period after implant loading

    CHARACTERIZATION OF F107 FIMBRIAE OF ESCHERICHIA-COLI 107/86, WHICH CAUSES EDEMA DISEASE IN PIGS, AND NUCLEOTIDE-SEQUENCE OF THE F107 MAJOR FIMBRIAL SUBUNIT GENE, FEDA

    Get PDF
    F107 fimbriae were isolated and purified from edema disease strain 107/86 of Escherichia coli. Plasmid pIH120 was constructed, which contains the gene cluster that codes for adhesive F107 fimbriae. The major fimbrial subunit gene, fedA, was sequenced. An open reading frame that codes for a protein with 170 amino acids, including a 21-amino-acid signal peptide, was found. The protein without the signal sequence has a calculated molecular mass of 15,099 Da. Construction of a nonsense mutation in the open reading frame of fedA abolished both fimbrial expression and the capacity to adhere to isolated porcine intestinal villi. In a screening of 28 reference edema disease strains and isolates from clinically ill piglets, fedA was detected in 24 cases (85.7%). In 20 (83.3%) of these 24 strains, fedA was found in association with Shiga-like toxin II variant genes, coding for the toxin that is characteristic for edema disease strains of E. coli. The fimbrial subunit gene was not detected in enterotoxigenic E. coli strains. Because of the capacity of E. coli HB101(pIH120) transformants to adhere to isolated porcine intestinal villi, the high prevalence of fedA in edema disease strains, and the high correlation with the Shiga-like toxin II variant toxin-encoding genes, we suggest that F107 fimbriae are an important virulence factor in edema disease strains of E. coli

    Analytical expressions for the conductance noise measured with four circular contacts placed in a square array

    Get PDF
    In the ideal case, noise measurements with four contacts minimize the contribution of the contact interface. There is a need to characterize conductance noise and noise correction factors for the different geometries provided with four contacts, as already is the case for resistivity measurements with van der Pauw structures. Here, we calculate the noise correction factors for two geometries with a pair of sensors and a pair of current driver electrodes placed in a square array. The first geometry investigated is a very large film compared to the distance L between four circular electrodes, which are placed in a square array far away from the borders of the film. The second is a square-shaped conductive film with side length L and provided with four quarter-circle corner contacts with radius l. The effect of the conductance noise in the film can be observed between current free sensors in a four-point measurement or between current carrying drivers in a two-point measurement. Our analytical expressions are based on approximations to solve the integrals (J·)2dA and |J|4dA for the voltage noise measured across a pair of sensors, SVQ, and across the drivers, SVD, respectively. The first and second integrands represent the squared dot product of the current density and adjoint current density and the modulus of the current density to the fourth power, respectively. The current density J in the samples is due to the current I passing through the driver contacts. The calculated expressions are applicable to samples with thickness tl0.1L. Hence, the disturbances in the neighborhood of the sensors on J and of the drivers on are ignored. Noise correction factors for two- and four-point measurements are calculated for sensors on an equipotential (transversal noise) with the driver contacts on the diagonal of a square and for sensors next to each other on one side of the square with the drivers next to each other on the other side of the square (longitudinal noise). In all cases the noise between the sensors is smaller and less sensitive to the contact size 2l/L than the noise between the drivers. The ratio SVQ/SVD becomes smaller with smaller contact radius l. Smaller sensors give a better suppression of interface noise at the contacts. But overly low 2l/L values result in overly high resistance between the sensors and too strong a contribution of thermal noise at the sensors. Therefore, equations are derived to calculate the current level needed to observe 1/f conductance fluctuations on top of the thermal noise. The results from the calculated analytical expressions show good agreement with experimental results obtained from the noise in carbon sheet resistance and numerical results. Transversal noise measurements on a square sample with corner contacts are recommended to characterize the 1/f noise of the layer. This is due to the increased current densities in the sample compared to the open structure, which result in easier detection of the 1/f on top of the thermal noise. ©2007 American Institute of Physic

    Development of a species-specific polymerase chain reaction assay for Gardnerella vaginalis

    Get PDF
    The nucleotide sequence of the region between the 16S and 23S rRNA genes of the facultative anaerobic bacteriumGardnerella vaginalishas been determined, together with the 5′ proximal 500 nucleotides of the 23S rRNA gene. Regions suited for the development of specific, probe-confirmable polymerase chain reaction (PCR) assays were selected. PCR assays were evaluated with respect to sensitivity and specificity, the latter in comparison with a number ofG. vaginalisreference strains and closely related species likeBifidobacteriumspp. In an initial diagnostic study it appeared that the PCR test detectedG. vaginalisin 40% of women irrespective of their clinical status. Ten out of 11 patients suffering from bacterial vaginosis as defined on the basis of clinical parameters were carryingG. vaginalis
    • …
    corecore