10 research outputs found
The optical design and performance of a concentrator photovoltaic module
Concentration photovoltaic (CPV) modules promise a more efficient, higher power output than traditional photovoltaic modules. This is achieved by concentrating sunlight onto a small 1 cm2 concentrator triple-junction (CTJ) InGaP/InGaAs/Ge cell by using high quality precision optics. In order to achieve high energy performance and reliability, well thought-out design decisions must be made in the development of a CPV module. This paper investigates the design of two CPV modules (Module I and II), which are based on the Sandia III Baseline Fresnel module. The investigation concentrated on the effect of the optimization of the optical design on the electrical performance characteristics of CTJ cells with good thermal dissipation. The best performance achieved by Module I was at 336 times operational concentration (Xo), which produced a Pmax of 10.29 W per cell, with cell and module efficiencies of 39% and 24%, respectively. In the development of the second module (Module II) pre-deployment criteria such as the CTJ cell and system components characteristics was used to eliminate faulty components from the system what was observed in Module I. Cell units that were optimized in Module II showed no form of degradation in their Current-Voltage (I-V) characteristics. The cell unit operating under optical misalignment showed a progressive degradation with long term operation in the field
Identification and characterisation of performance limiting defects and cell mismatch in photovoltaic modules
The performance and longevity of photovoltaic (PV) modules can be severely limited by cell mismatch occurring when a solar cell in a series-connected string produces a lower current than the other cells in that string. The current output of the entire string is limited by the weakest cell in the string so shading or damage to a single cell in a module can affect the entire module’s current output. Electrolumin-escence (EL) occurs when a positive current and voltage are applied to a solar cell and is used to identify damage and defects in the cell. In this study, the cell mismatch in three single crystalline silicon modules was investigated using EL and current-voltage (I-V) characterisation techniques. Two modules have a white discolouration that affects the majority of the cells in the module and also have signs of mechanical damage, while the third module acts as a reference as it has no discolouration and appears undamaged. The EL signal intensity is related to cell performance and identifies material defects, bad contacts and broken cells. Cell mismatch in a module results in a decrease in the performance parameters obtained from the I-V characteristic curve of the module. The I-V curves indicate the presence of current mismatch in the degraded modules, which is supported by the EL images of these modules. The use of EL images, in conjunction with the I-V curves, allows the degradation in the modules to be characterised
The optical design and performance of a concentrator photovoltaic module
Concentration photovoltaic (CPV) modules promise a more efficient, higher power output than traditional photovoltaic modules. This is achieved by concentrating sunlight onto a small 1 cm2 concentrator triple-junction (CTJ) InGaP/InGaAs/Ge cell by using high quality precision optics. In order to achieve high energy performance and reliability, well thought-out design decisions must be made in the development of a CPV module. This paper investigates the design of two CPV modules (Module I and II), which are based on the Sandia III Baseline Fresnel module. The investigation concentrated on the effect of the optimization of the optical design on the electrical performance characteristics of CTJ cells with good thermal dissipation. The best performance achieved by Module I was at 336 times operational concentration (Xo), which produced a Pmax of 10.29 W per cell, with cell and module efficiencies of 39% and 24%, respectively. In the development of the second module (Module II) pre-deployment criteria such as the CTJ cell and system components characteristics was used to eliminate faulty components from the system what was observed in Module I. Cell units that were optimized in Module II showed no form of degradation in their Current-Voltage (I-V) characteristics. The cell unit operating under optical misalignment showed a progressive degradation with long term operation in the field
Development of a Smart Monitoring and Evaluation Framework for Hybrid Renewable Mini-grids
Hybrid renewable mini-grids have emerged as a viable solution for providing reliable, environmentally friendly electricity to remote communities. An affordable and grid-quality supply of energy can open new possibilities for socioeconomic progress. As part of a joint project between South Africa’s Eastern Cape province and Germany’s state of Lower Saxony a Photovoltaic (PV) hybrid mini-grid is developed in the municipality of Upper Blinkwater in Eastern Cape for a rural community of 70 households with 90 percent living off of social grants and no access to the main national grid. The aim of this work is to develop a smart Monitoring and Evaluation Framework (MEF) for hybrid renewable mini-grids by integrating cutting-edge technologies in a scalable platform of replicable solutions towards connecting the mini-grid with diverse stakeholders with enhanced observability of both generation and consumption profiles. The MEF provides the opportunity to streamline the flow of real-time energy data (generation, consumption, and storage) from the system to generate accurate and high-resolution data-driven load profiles for rural households. Simultaneously, the interrelation between energy access and social development will be studied and analyzed
SAURAN: A new resource for solar radiometric data in Southern Africa
A new resource for sun strength data in Southern Africa has been established with the commissioning of a regional network of solar monitoring stations. The Southern African Universities Radiometric Network (SAURAN) is an initiative of Stellenbosch University and the University of KwaZulu-Natal (UKZN), and consists of an initial set of ten ground stations equipped with secondary standard thermopile radiometers. SAURAN’s aim is to provide a long-term record of sun strength in a region that shows excellent potential for the deployment of solar energy technologies. Instruments measuring direct normal irradiance (DNI), diffuse horizontal irradiance (DHI) and global horizontal irradiance (GHI) feed time-averaged data over 1-minute, hourly and daily intervals to a central archive from where they are accessible to the public via a website interface. Meteorological data is also provided by most of the stations. This paper gives a brief background to the SAURAN project and describes the network’s operation, coverage and future expansion. Examples of solar energy irradiance plots are also provided to illustrate the information available from the SAURAN database
SAURAN: A new resource for solar radiometric data in Southern Africa
A new resource for sun strength data in Southern Africa has been established with the commissioning of a regional network of solar monitoring stations. The Southern African Universities Radiometric Network (SAURAN) is an initiative of Stellenbosch University and the University of KwaZulu-Natal (UKZN), and consists of an initial set of ten ground stations equipped with secondary standard thermopile radiometers. SAURAN’s aim is to provide a long-term record of sun strength in a region that shows excellent potential for the deployment of solar energy technologies. Instruments measuring direct normal irradiance (DNI), diffuse horizontal irradiance (DHI) and global horizontal irradiance (GHI) feed time-averaged data over 1-minute, hourly and daily intervals to a central archive from where they are accessible to the public via a website interface. Meteorological data is also provided by most of the stations. This paper gives a brief background to the SAURAN project and describes the network’s operation, coverage and future expansion. Examples of solar energy irradiance plots are also provided to illustrate the information available from the SAURAN database
SAURAN : a new resource for solar radiometric data in Southern Africa
CITATION: Brooks, M. J. et al. 2015. SAURAN : a new resource for solar radiometric data in Southern Africa. Journal of Energy in Southern Africa, 26(1):2-10.The original publication is available at http://www.scielo.org.zaA new resource for sun strength data in Southern Africa has been established with the commissioning of a regional network of solar monitoring stations. The Southern African Universities Radiometric Network (SAURAN) is an initiative of Stellenbosch University and the University of KwaZulu-Natal (UKZN), and consists of an initial set of ten ground stations equipped with secondary standard thermopile radiometers. SAURAN's aim is to provide a long-term record of sun strength in a region that shows excellent potential for the deployment of solar energy technologies. Instruments measuring direct normal irradiance (DNI), diffuse horizontal irradiance (DHI) and global horizontal irradiance (GHI) feed time-averaged data over 1-minute, hourly and daily intervals to a central archive from where they are accessible to the public via a website interface. Meteorological data is also provided by most of the stations. This paper gives a brief background to the SAURAN project and describes the network's operation, coverage and future expansion. Examples of solar energy irradiance plots are also provided to illustrate the information available from the SAURAN database.http://www.scielo.org.za/scielo.php?script=sci_abstract&pid=S1021-447X2015000100001&lng=en&nrm=iso&tlng=enPublisher's versio
Maternal and neonatal outcomes after caesarean delivery in the African Surgical Outcomes Study: a 7-day prospective observational cohort study.
BACKGROUND: Maternal and neonatal mortality is high in Africa, but few large, prospective studies have been done to investigate the risk factors associated with these poor maternal and neonatal outcomes. METHODS: A 7-day, international, prospective, observational cohort study was done in patients having caesarean delivery in 183 hospitals across 22 countries in Africa. The inclusion criteria were all consecutive patients (aged ≥18 years) admitted to participating centres having elective and non-elective caesarean delivery during the 7-day study cohort period. To ensure a representative sample, each hospital had to provide data for 90% of the eligible patients during the recruitment week. The primary outcome was in-hospital maternal mortality and complications, which were assessed by local investigators. The study was registered on the South African National Health Research Database, number KZ_2015RP7_22, and on ClinicalTrials.gov, number NCT03044899. FINDINGS: Between February, 2016, and May, 2016, 3792 patients were recruited from hospitals across Africa. 3685 were included in the postoperative complications analysis (107 missing data) and 3684 were included in the maternal mortality analysis (108 missing data). These hospitals had a combined number of specialist surgeons, obstetricians, and anaesthetists totalling 0·7 per 100 000 population (IQR 0·2-2·0). Maternal mortality was 20 (0·5%) of 3684 patients (95% CI 0·3-0·8). Complications occurred in 633 (17·4%) of 3636 mothers (16·2-18·6), which were predominantly severe intraoperative and postoperative bleeding (136 [3·8%] of 3612 mothers). Maternal mortality was independently associated with a preoperative presentation of placenta praevia, placental abruption, ruptured uterus, antepartum haemorrhage (odds ratio 4·47 [95% CI 1·46-13·65]), and perioperative severe obstetric haemorrhage (5·87 [1·99-17·34]) or anaesthesia complications (11·47 (1·20-109·20]). Neonatal mortality was 153 (4·4%) of 3506 infants (95% CI 3·7-5·0). INTERPRETATION: Maternal mortality after caesarean delivery in Africa is 50 times higher than that of high-income countries and is driven by peripartum haemorrhage and anaesthesia complications. Neonatal mortality is double the global average. Early identification and appropriate management of mothers at risk of peripartum haemorrhage might improve maternal and neonatal outcomes in Africa. FUNDING: Medical Research Council of South Africa.Medical Research Council of South Africa
The ASOS Surgical Risk Calculator: development and validation of a tool for identifying African surgical patients at risk of severe postoperative complications
Background:
The African Surgical Outcomes Study (ASOS) showed that surgical patients in Africa have a mortality twice the global average. Existing risk assessment tools are not valid for use in this population because the pattern of risk for poor outcomes differs from high-income countries. The objective of this study was to derive and validate a simple, preoperative risk stratification tool to identify African surgical patients at risk for in-hospital postoperative mortality and severe complications.
Methods:
ASOS was a 7-day prospective cohort study of adult patients undergoing surgery in Africa. The ASOS Surgical Risk Calculator was constructed with a multivariable logistic regression model for the outcome of in-hospital mortality and severe postoperative complications. The following preoperative risk factors were entered into the model; age, sex, smoking status, ASA physical status, preoperative chronic comorbid conditions, indication for surgery, urgency, severity, and type of surgery.
Results:
The model was derived from 8799 patients from 168 African hospitals. The composite outcome of severe postoperative complications and death occurred in 423/8799 (4.8%) patients. The ASOS Surgical Risk Calculator includes the following risk factors: age, ASA physical status, indication for surgery, urgency, severity, and type of surgery. The model showed good discrimination with an area under the receiver operating characteristic curve of 0.805 and good calibration with c-statistic corrected for optimism of 0.784.
Conclusions:
This simple preoperative risk calculator could be used to identify high-risk surgical patients in African hospitals and facilitate increased postoperative surveillance.
© 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.Medical Research Council of South Africa gran