8,134 research outputs found
Relaxed exact spectral controllability of membrane shells
AbstractFor membrane shells, where the exact controllability generally fails, results of relaxed exact controllability using spectral and asymptotic properties of the membrane elastic operator, are given
Mechanical behaviour with temperatures of aluminum matrix composites with CNTs
Aluminum is a very useful structural metal employed in different industrial sectors, in particular it is used in
large quantities in automotive, aeronautic and nautical industries. The main reasons of its wide use are: a very
good oxidation resistance, excellent ductility, low melting temperature (660 °C) and low density (2.71 g/cm3).
However, in order to reduce the emissions and fuel consumption is necessary to reduce the overall weight of
vehicles by increasing mechanical properties of the structural material. The improvement of mechanical
properties is normally achieved through use of reinforcement in materials, used like matrix, in order to improve
some specific characteristics.
In this work composites of carbon nanotubes (CNTs) dispersed in aluminum were made. The most difficulties
in the preparation of this type of composite are represented by the low wettability between metallic matrix and
fillers and the possibility of the oxidation of metal during melting with consequent decreasing of mechanical
proprieties. The composite was obtained by three consecutive step: the first one is the functionalization of
fillers surface to improve the fillers dispersion, the second one is the dispersion of fillers in the matrix by
powder mixing and the third one is the melting and casting of the mix prepared.
In particular, fillers used are multi walled carbon nanotubes (MWCNTs) with functionalized surface by
treatment with a solfonitric solution. Melting and casting are carried out with the aid of an induction furnace
with a controlled atmosphere system and centrifugal casting. Argon is the inert gas used to prevent the
oxidation of aluminium during fusion. Young’s modulus was evaluated at different temperature and correlated
with the different CNTs percentage. The dispersion rate of fillers and the microstructure of the sample were
evaluated by FESEM micrograph
Simulation and experimental evaluation of a flexible time triggered ethernet architecture applied in satellite nano/micro launchers
The success of small satellites has led to the study of new technologies for the realization of Nano and Micro Launch Vehicle (NMLV) in order to make competitive launch costs. The paper has the objective to define and experimentally investigate the performance of a communication system for NMLV interconnecting the End Systems as On-Board Computer (OBC), telemetry apparatus, Navigation Unit...we propose a low cost Ethernet-based solution able to provide the devices with high interconnection bandwidth. To guarantee hard delays to the Guide, Navigation and Control applications we propose some architectural changes of the traditional Ethernet network with the introduction of a layer implemented in the End Systems and allow for the lack of any contention on the network links. We show how the proposed solution has comparable performance to the one of TTEthernet standard that is a very expensive solution. An experimental test-bed equipped with Ethernet switches and Hercules boards by Texas Instruments is also provided to prove the feasibility of the proposed solution
A 32-by-32 CMOS microelectrode array for capacitive biosensing and impedance spectroscopy
This paper presents the design of a 1024-channel dual-modality CMOS biosensor suitable for both capacitive sensing and impedance spectroscopy. The chip serves as a platform for detection, localization and monitoring of bacteria and can be adopted for affinity-based assays. The chip features a 32×32 array of unpassivated metal electrodes formed on the top metal of a 0.18μm CMOS process, with an overall sensing area of 2.06 mm2. The system design is based on a shared in-pixel integrator that can be used as a charge amplifier for capacitive sensing (CS) or as part of a transimpedance amplifier for electrical impedance spectroscopy (EIS). The CS mode is capable of a operation bandwidth of 50 MHz at a current consumption of 82 μA per pixel. The EIS channel operates over a bandwidth between 100 Hz and 1 MHz with a total input-referred current noise of 48 pArms and a current consumption of 210 μA per channel
Wideband Fully-Programmable Dual-Mode CMOS Analogue Front-End for Electrical Impedance Spectroscopy
This paper presents a multi-channel dual-mode CMOS analogue front-end (AFE) for electrochemical and bioimpedance analysis. Current-mode and voltage-mode readouts, integrated on the same chip, can provide an adaptable platform to correlate single-cell biosensor studies with large-scale tissue or organ analysis for real-time cancer detection, imaging and characterization. The chip, implemented in a 180-nm CMOS technology, combines two current-readout (CR) channels and four voltage-readout (VR) channels suitable for both bipolar and tetrapolar electrical impedance spectroscopy (EIS) analysis. Each VR channel occupies an area of 0.48 mm 2 , is capable of an operational bandwidth of 8 MHz and a linear gain in the range between -6 dB and 42 dB. The gain of the CR channel can be set to 10 kΩ, 50 kΩ or 100 kΩ and is capable of 80-dB dynamic range, with a very linear response for input currents between 10 nA and 100 μ A. Each CR channel occupies an area of 0.21 mm 2 . The chip consumes between 530 μ A and 690 μ A per channel and operates from a 1.8-V supply. The chip was used to measure the impedance of capacitive interdigitated electrodes in saline solution. Measurements show close matching with results obtained using a commercial impedance analyser. The chip will be part of a fully flexible and configurable fully-integrated dual-mode EIS system for impedance sensors and bioimpedance analysis
Dual-mode CMOS analog front-end (AFE) for electrical impedance spectroscopy (EIS) systems
This paper presents the operation of a dualmode wideband CMOS analog front-end (AFE) for electrical impedance spectroscopy. The chip combines two current-readout (CR) channels and four voltage-readout (VR) channels suitable for both bipolar and tetrapolar EIS analysis. The chip addresses the need for flexible readout units for real-time simultaneous single-cell and large scale tissue/organ analysis. Postlayout simulations show that the VR channel is capable of wideband operation up to 12 MHz with noise floor as low as 16.4 nV/Hz1/2. A 2-bit control allows to select between a high-frequency low-gain channel and a bandwidth-limited high-gain channel. Each VR channel occupies an area of 0.48 mm2. The CR channel is capable of 80 dB of dynamic range, by converting currents between 1 nA to 10μA, while achieving a noise floor of 1.4 pA/Hz1/2. An automatic gain control (AGC) unit can be enabled in order maintain the sensor signal within the ADC dynamic range. Each CR channel occupies an area of 0.21 mm2. The chip consumes between 290 μA and 690 μA per channel and operates from a 1.8 V supply. The chip will be part of a fully flexible and configurable dual-mode EIS systems for impedance sensors and bioimpedance analysis
Optimal irreversible stimulated emission
We studied the dynamics of an initially inverted atom in a semi-infinite
waveguide, in the presence of a single propagating photon. We show that atomic
relaxation is enhanced by a factor of 2, leading to maximal bunching in the
output field. This optimal irreversible stimulated emission is a novel
phenomenon that can be observed with state-of-the-art solid-state atoms and
waveguides. When the atom interacts with two one-dimensional electromagnetic
environments, the preferential emission in the stimulated field can be
exploited to efficiently amplify a classical or a quantum state.Comment: 9 pages, 6 figure
Firm exit during economic slowdowns: does foreign ownership matter?
Do multinationals’ activities contribute to the severity of global economic crisis by quickly closing down
facilities or otherwise allow to mitigating some of the worst effects, by remaining rooted in the local economy
and thus reducing lay-offs and output contraction in the host countries?
The present paper provides an empirical analysis on the link between foreign ownership and firm survival over
an almost 20-year period and during two economic downturns in particular, using an extensive firm-level
database and applying hazard models. We analyse the determinants of exit of firms and investigate whether
there are significant differences in the hazard rates of foreign and domestic firms when controlling for firm and
industry specificities. Additionally we assess whether the foreignness effect alters during economic downturns
and whether any spillovers arise from the multinationals’ presence in the industry.
After controlling for several firm and industry specific characteristics, we find that foreign firms exhibit higher
failure rates over the time period as a whole. However, during economic slowdowns domestic and foreign firms
do not exhibit different chances of survival and exit. Finally, regarding potential spillovers, our results suggest
that foreign presence may impact positively upon local firms’ survival
- …