6 research outputs found

    Image quality characterisation in computed tomography to assess the relevant diagnostic information

    Get PDF

    Photon-Counting Detector CT for Liver Lesion Detection-Optimal Virtual Monoenergetic Energy for Different Simulated Patient Sizes and Radiation Doses

    Get PDF
    OBJECTIVES The aim of this study was to evaluate the optimal energy level of virtual monoenergetic images (VMIs) from photon-counting detector computed tomography (CT) for the detection of liver lesions as a function of phantom size and radiation dose. MATERIALS AND METHODS An anthropomorphic abdominal phantom with liver parenchyma and lesions was imaged on a dual-source photon-counting detector CT at 120 kVp. Five hypoattenuating lesions with a lesion-to-background contrast difference of -30 HU and -45 HU and 3 hyperattenuating lesions with +30 HU and +90 HU were used. The lesion diameter was 5-10 mm. Rings of fat-equivalent material were added to emulate medium- or large-sized patients. The medium size was imaged at a volume CT dose index of 5, 2.5, and 1.25 mGy and the large size at 5 and 2.5 mGy, respectively. Each setup was imaged 10 times. For each setup, VMIs from 40 to 80 keV at 5 keV increments were reconstructed with quantum iterative reconstruction at a strength level of 4 (QIR-4). Lesion detectability was measured as area under the receiver operating curve (AUC) using a channelized Hotelling model observer with 10 dense differences of Gaussian channels. RESULTS Overall, highest detectability was found at 65 and 70 keV for both hypoattenuating and hyperattenuating lesions in the medium and large phantom independent of radiation dose (AUC range, 0.91-1.0 for the medium and 0.94-0.99 for the large phantom, respectively). The lowest detectability was found at 40 keV irrespective of the radiation dose and phantom size (AUC range, 0.78-0.99). A more pronounced reduction in detectability was apparent at 40-50 keV as compared with 65-75 keV when radiation dose was decreased. At equal radiation dose, detection as a function of VMI energy differed stronger for the large size as compared with the medium-sized phantom (12% vs 6%). CONCLUSIONS Detectability of hypoattenuating and hyperattenuating liver lesions differed between VMI energies for different phantom sizes and radiation doses. Virtual monoenergetic images at 65 and 70 keV yielded highest detectability independent of phantom size and radiation dose

    Konzepte zur Charakterisierung klinischer CT-Systeme unter Einbeziehung von Bildqualität und Dosis

    No full text
    In Germany, as in most Western countries, the exposure to the population due to CT examinations has increased over the last twenty years, despite major technological progresses which might lead to the expectation that doses would decrease. The last survey organized in Germany showed that in 2014 the average dose per inhabitant due to CT was 1.0 mSv compared to 0.8 mSv in 2007. Thus, the use of CT is a major source of concern for Public Health Authorities such as the “Bundesamts für Stahlenchutz” in Germany. Among the ways to control the population exposure creeping upwards one should ensure that the principle of justification is correctly applied and that the radiological examination and intervention are optimized in terms of the balance of low dose against required image quality. In the context of optimization, the units used should work efficiently to ensure that there is no waste of radiation in the imaging process. The aim of this project is to propose a way to benchmark CT units, allowing the assessment of the efficiency of CT units using clinically relevant protocols. The project was made of four work-packages. The first work-package was a review of the literature dedicated to image quality assessment in CT imaging. During this work-package the clinically relevant protocols used for benchmarking were also defined. The second work-package was dedicated to the set-up of the methodology to be used when dealing with the benchmarking of CT units using two different concepts. The third work-package was the application of these concepts on eight CT units; including two models from each of four manufacturers. Finally, the fourth work-package consisted in the analysis of the data with the proposal of a strategy to establish a dose efficiency index (DEI) to quantify the CT unit performances

    Annual exposure of the Swiss population from medical imaging in 2018

    No full text
    Nationwide surveys on radiation dose to the population from medical imaging are recommended in order to follow trends in population exposure. The goal of the 2018 survey was to investigate the current exposure. The invoice coding information was collected in five university hospitals and large clinics. To improve the estimation of the effective dose delivered in computed tomography (CT), we collected dose data from different Dose Archiving Communication Systems. On average, we found that 1.2 radiological examinations per year and per inhabitant were performed. Dental radiography was the most frequent examination (48% of all the X-ray examinations), followed by conventional radiography (36%) and CT (11%). The average annual effective dose was estimated to be 1.48 mSv per inhabitant, with CT representing 64% of that dose. Our results show that the exposure of the Swiss population from medical imaging has remained stable since 2013, despite a 15% increase in the number of CT examinations

    Photon-Counting Detector CT With Quantum Iterative Reconstruction: Impact on Liver Lesion Detection and Radiation Dose Reduction

    Full text link
    OBJECTIVES To assess image noise, diagnostic performance, and potential for radiation dose reduction of photon-counting detector (PCD) computed tomography (CT) with quantum iterative reconstruction (QIR) in the detection of hypoattenuating and hyperattenuating focal liver lesions compared with energy-integrating detector (EID) CT. MATERIALS AND METHODS A medium-sized anthropomorphic abdominal phantom with liver parenchyma and lesions (diameter, 5-10 mm; hypoattenuating and hyperattenuating from -30 HU to +90 HU at 120 kVp) was used. The phantom was imaged on (a) a third-generation dual-source EID-CT (SOMATOM Force, Siemens Healthineers) in the dual-energy mode at 100 and 150 kVp with tin filtration and (b) a clinical dual-source PCD-CT at 120 kVp (NAEOTOM Alpha, Siemens). Scans were repeated 10 times for each of 3 different radiation doses of 5, 2.5, and 1.25 mGy. Datasets were reconstructed as virtual monoenergetic images (VMIs) at 60 keV for both scanners and as linear-blended images (LBIs) for EID-CT. For PCD-CT, VMIs were reconstructed with different strength levels of QIR (QIR 1-4) and without QIR (QIR-off). For EID-CT, VMIs and LBIs were reconstructed using advanced modeled iterative reconstruction at a strength level of 3. Noise power spectrum was measured to compare image noise magnitude and texture. A channelized Hotelling model observer was used to assess diagnostic accuracy for lesion detection. The potential for radiation dose reduction using PCD-CT was estimated for the QIR strength level with the highest area under the curve compared with EID-CT for each radiation dose. RESULTS Image noise decreased with increasing QIR level at all radiation doses. Using QIR-4, noise reduction was 41%, 45%, and 59% compared with EID-CT VMIs and 12%, 18%, and 33% compared with EID-CT LBIs at 5, 2.5, and 1.25 mGy, respectively. The peak spatial frequency shifted slightly to lower frequencies at higher QIR levels. Lesion detection accuracy increased at higher QIR levels and was higher for PCD-CT compared with EID-CT VMIs. The improvement in detection with PCD-CT was strongest at the lowest radiation dose, with an area under the receiver operating curve of 0.917 for QIR-4 versus 0.677 for EID-CT VMIs for hyperattenuating lesions, and 0.900 for QIR-4 versus 0.726 for EID-CT VMIs for hypoattenuating lesions. Compared with EID-CT LBIs, detection was higher for QIR 1-4 at 2.5 mGy and for QIR 2-4 at 1.25 mGy (eg, 0.900 for QIR-4 compared with 0.854 for EID-CT LBIs at 1.25 mGy). Radiation dose reduction potential of PCD-CT with QIR-4 was 54% at 5 mGy compared with VMIs and 39% at 2.5 mGy compared with LBIs. CONCLUSIONS Compared with EID-CT, PCD-CT with QIR substantially improved focal liver lesion detection, especially at low radiation dose. This enables substantial radiation dose reduction while maintaining diagnostic accuracy
    corecore