10 research outputs found

    Effects of a partially supervised conditioning programme in cystic fibrosis: an international multi-centre randomised controlled trial (ACTIVATE-CF): study protocol

    Get PDF
    Physical activity (PA) and exercise have become an accepted and valued component of cystic fibrosis (CF) care. Regular PA and exercise can positively impact pulmonary function, improve physical fitness, and enhance health-related quality of life (HRQoL). However, motivating people to be more active is challenging. Supervised exercise programs are expensive and labour intensive, and adherence falls off significantly once supervision ends. Unsupervised or partially supervised programs are less costly and more flexible, but compliance can be more problematic. The primary objective of this study is to evaluate the effects of a partially supervised exercise intervention along with regular motivation on forced expiratory volume in 1 s (FEV1) at 6 months in a large international group of CF patients. Secondary endpoints include patient reported HRQoL, as well as levels of anxiety and depression, and control of blood sugar.; It is planned that a total of 292 patients with CF 12 years and older with a FEV1 ≥ 35% predicted shall be randomised. Following baseline assessments (2 visits) patients are randomised into an intervention and a control group. Thereafter, they will be seen every 3 months for assessments in their centre for one year (4 follow-up visits). Along with individual counselling to increase vigorous PA by at least 3 h per week on each clinic visit, the intervention group documents daily PA and inactivity time and receives a step counter to record their progress within a web-based diary. They also receive monthly phone calls from the study staff during the first 6 months of the study. After 6 months, they continue with the step counter and web-based programme for a further 6 months. The control group receives standard care and keeps their PA level constant during the study period. Thereafter, they receive the intervention as well.; This is the first large, international multi-centre study to investigate the effects of a PA intervention in CF with motivational feedback on several health outcomes using modern technology. Should this relatively simple programme prove successful, it will be made available on a wider scale internationally.; ClinicalTrials.gov Identifier: NCT01744561 ; Registration date: December 6, 2012

    Six-minute walking test in children with ESRD: discrimination validity and construct validity

    Get PDF
    The six-minute walking test (6MWT) may be a practical test for the evaluation functional exercise capacity in children with end-stage renal disease (ESRD). The aim of this study was to investigate the 6MWT performance in children with ESRD compared to reference values obtained in healthy children and, secondly, to study the relationship between 6MWT performance with anthropometric variables, clinical parameters, aerobic capacity and muscle strength. Twenty patients (13 boys and seven girls; mean age 14.1 ± 3.4 years) on dialysis participated in this study. Anthropometrics were taken in a standardized manner. The 6MWT was performed in a 20-m-long track in a straight hallway. Aerobic fitness was measured using a cycle ergometer test to determine peak oxygen uptake \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}(V⋅O2peak) \left( {\mathop {\text{V}}\limits^\cdot {{\text{O}}_{\text{2peak}}}} \right) \end{document}, peak rate (Wpeak) and ventilatory threshold (VT). Muscle strength was measured using hand-held myometry. Children with ESRD showed a reduced 6MWT performance (83% of predicted, p < 0.0001), irrespective of the reference values used. The strongest predictors of 6MWT performance were haematocrit and height. Regression models explained 59% (haematocrit and height) to 60% (haematocrit) of the variance in 6MWT performance. 6MWT performance was not associated with \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}V⋅O2peak {\mathop {\text{V}}\limits^\cdot {{\text{O}}_{\text{2peak}}}} \end{document}, strength, or other anthropometric variables, but it was significantly associated with haematocrit and height. Children with ESRD scored lower on the 6MWT than healthy children. Based on these results, the 6MWT may be a useful instrument for monitoring clinical status in children with ESRD, however it cannot substitute for other fitness tests, such as a progressive exercise test to measure \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}V⋅O2peak {\mathop {\text{V}}\limits^\cdot {{\text{O}}_{\text{2peak}}}} \end{document} or muscle strength tests
    corecore