8 research outputs found

    Vault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lens

    Get PDF
    Posterior chamber phakic intraocular lens (pIOL) implantation is a common option for correcting moderate-to-high ocular refractive defects. Because this pIOL is implanted on ciliary sulcus, the distance between the back surface of the pIOL and the anterior surface of the crystalline lens, that it is known as vault, should be measured in different conditions to ensure the technique's safety. Cyclopentolate is a drug that dilates the pupil and relaxes accommodation (cycloplegia). It is often used for different ocular examinations and for other medical purposes. However, there is no evidence of the effect of this drug on vault. This study quantified central vault changes associated with cyclopentolate instillation. We measured the vault under normal conditions (pre-cycloplegic instillation) and after instilling cyclopentolate on 39 eyes of 39 patients with implanted pIOL. Our results suggest that cyclopentolate instillation may induce changes to vault in eyes with implanted pIOL. These changes seem safe and are mainly associated with vault under normal conditions, but also with anterior chamber depth, pupillary diameter and pIOL size.- European Fund for Regional Development (FEDER) through the COMPETE Program and the Portuguese Foundation for Science and Technology (FCT) provided financial support in the framework of projects PTDC/SAU-BEB/098391/2008, PTDC/SAU-BEB/098392/2008 and the Strategic Project PEST-C/FIS/UI607/2011

    Intraocular pressure rise after small incision cataract surgery: a randomised intraindividual comparison of two dispersive viscoelastic agents

    No full text
    AIM—To evaluate the effects of the dispersive viscoelastic agents Ocucoat (hydroxypropyl methylcellulose 2%) and Viscoat (sodium chondroitin sulphate 4%-sodium hyaluronate 3%) on postoperative intraocular pressure (IOP) after bilateral small incision cataract surgery.
METHODS—This prospective, randomised study comprised 80 eyes of 40 consecutive patients with age related cataract in both eyes scheduled for bilateral small incision cataract surgery. The patients were randomly assigned to receive Ocucoat or Viscoat during cataract surgery of the first eye. The second eye was operated later and received the other viscoelastic agent. Cataract surgery was performed with a temporal 3.2 mm sutureless posterior limbal incision, phacoemulsification, and implantation of a foldable silicone intraocular lens. The IOP was measured preoperatively as well as 6 hours, 20-24 hours, and 1 week postoperatively.
RESULTS—At 6 hours after surgery the mean IOP increased by 4.6 (SD 5.1) mm Hg in the Ocucoat group (p<0.001) and by 8.6 (8.1) mm Hg in the Viscoat group (p<0.001). The increase was significantly higher in the Viscoat group than in the Ocucoat group (p=0.004). Intraocular pressure spikes of 30 mm Hg or more occurred in two eyes in the Ocucoat and in nine eyes in the Viscoat group (p=0.023); 20-24 hours and 1 week postoperatively the mean IOP was not statistically different.
CONCLUSION—These findings indicate that Viscoat causes a significantly higher IOP increase and significantly more IOP spikes than Ocucoat in the early period after small incision cataract surgery.


    Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects

    No full text
    Aims/background: To investigate the reproducibility and potential diurnal variation of choroidal blood flow parameters in healthy subjects over a period of 12 hours. Methods: The choroidal blood flow parameters of 16 healthy non-smoking subjects were measured at five time points during the day (8:00, 11:00, 14:00, 17:00, and 20:00). Outcome parameters were pulsatile ocular blood flow as assessed by pneumotonometry, fundus pulsation amplitude as assessed by laser interferometry, blood velocities in the opthalmic and posterior ciliary arteries as assessed by colour Doppler imaging, and choroidal blood flow, volume, and velocity as assessed by fundus camera based laser Doppler flowmetry. The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. Results: None of the techniques used found a diurnal variation in choroidal blood flow. Coefficients of variation were within 2.9% and 13.6% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 11.2% to 58.8%. Conclusions: These data indicate that in healthy subjects the selected techniques provide adequate reproducibility to be used in clinical studies. Variability may, however, be considerably higher in older subjects or subjects with ocular disease. The higher individual differences in flow parameter readings limit the use of the techniques in clinical practice. To overcome problems with measurement validity, a clinical trial should include as many choroidal blood flow outcome parameters as possible to check for consistency

    The posterior chamber phakic refractive lens (PRL): a review

    No full text
    Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on the latter is very low, and some concerns still remain about its long-term safety. The present article reviews the published literature on the outcomes after PRL implantation in order to provide a general overview and evaluate its real potential as a surgical refractive option
    corecore