30 research outputs found

    Validating the predictive ability of the 2MACE score for major adverse cardiovascular events in patients with atrial fibrillation:results from phase II/III of the GLORIA-AF registry

    Get PDF
    The 2MACE score was specifically developed as a risk-stratification tool in atrial fibrillation (AF) to predict cardiovascular outcomes. We evaluated the predictive ability of the 2MACE score in the GLORIA-AF registry. All eligible patients from phase II/III of the prospective global GLORIA-AF registry were included. Major adverse cardiac events (MACEs) were defined as the composite outcome of stroke, myocardial infarction and cardiovascular death. Cox proportional hazards were used to examine the relationship between the 2MACE score and study outcomes. Predictive capability of the 2MACE score was investigated using receiver-operating characteristic curves. A total of 25,696 patients were included (mean age 71 years, female 44.9%). Over 3 years, 1583 MACEs were recorded. Patients who had MACE were older, with more cardiovascular risk factors and were less likely to be managed using a rhythm-control strategy. The median 2MACE score in the MACE and non-MACE groups were 2 (IQR 1–3) and 1 (IQR 0–2), respectively (p < 0.001). The 2MACE score was positively associated with an increase in the risk of MACE, with a score of ≥ 2 providing the best combination of sensitivity (69.6%) and specificity (51.6%), HR 2.47 (95% CI, 2.21–2.77). The 2MACE score had modest predictive performance for MACE in patients with AF (AUC 0.655 (95% CI, 0.641–0.669)). Our analysis in this prospective global registry demonstrates that the 2MACE score can adequately predict the risk of MACE (defined as myocardial infarction, CV death and stroke) in patients with AF. Clinical trial registration: http://www.clinicaltrials.gov . Unique identifiers: NCT01468701, NCT01671007 and NCT01937377

    Patterns of oral anticoagulant use and outcomes in Asian patients with atrial fibrillation:a post-hoc analysis from the GLORIA-AF Registry

    Get PDF
    Background: Previous studies suggested potential ethnic differences in the management and outcomes of atrial fibrillation (AF). We aim to analyse oral anticoagulant (OAC) prescription, discontinuation, and risk of adverse outcomes in Asian patients with AF, using data from a global prospective cohort study. Methods: From the GLORIA-AF Registry Phase II–III (November 2011–December 2014 for Phase II, and January 2014–December 2016 for Phase III), we analysed patients according to their self-reported ethnicity (Asian vs. non-Asian), as well as according to Asian subgroups (Chinese, Japanese, Korean and other Asian). Logistic regression was used to analyse OAC prescription, while the risk of OAC discontinuation and adverse outcomes were analysed through Cox-regression model. Our primary outcome was the composite of all-cause death and major adverse cardiovascular events (MACE). The original studies were registered with ClinicalTrials.gov, NCT01468701, NCT01671007, and NCT01937377. Findings: 34,421 patients were included (70.0 ± 10.5 years, 45.1% females, 6900 (20.0%) Asian: 3829 (55.5%) Chinese, 814 (11.8%) Japanese, 1964 (28.5%) Korean and 293 (4.2%) other Asian). Most of the Asian patients were recruited in Asia (n = 6701, 97.1%), while non-Asian patients were mainly recruited in Europe (n = 15,449, 56.1%) and North America (n = 8378, 30.4%). Compared to non-Asian individuals, prescription of OAC and non-vitamin K antagonist oral anticoagulant (NOAC) was lower in Asian patients (Odds Ratio [OR] and 95% Confidence Intervals (CI): 0.23 [0.22–0.25] and 0.66 [0.61–0.71], respectively), but higher in the Japanese subgroup. Asian ethnicity was also associated with higher risk of OAC discontinuation (Hazard Ratio [HR] and [95% CI]: 1.79 [1.67–1.92]), and lower risk of the primary composite outcome (HR [95% CI]: 0.86 [0.76–0.96]). Among the exploratory secondary outcomes, Asian ethnicity was associated with higher risks of thromboembolism and intracranial haemorrhage, and lower risk of major bleeding. Interpretation: Our results showed that Asian patients with AF showed suboptimal thromboembolic risk management and a specific risk profile of adverse outcomes; these differences may also reflect differences in country-specific factors. Ensuring integrated and appropriate treatment of these patients is crucial to improve their prognosis. Funding: The GLORIA-AF Registry was funded by Boehringer Ingelheim GmbH.</p

    Anticoagulant selection in relation to the SAMe-TT<sub>2</sub>R<sub>2</sub> score in patients with atrial fibrillation:The GLORIA-AF registry

    Get PDF
    Aim: The SAMe-TT2R2 score helps identify patients with atrial fibrillation (AF) likely to have poor anticoagulation control during anticoagulation with vitamin K antagonists (VKA) and those with scores &gt;2 might be better managed with a target-specific oral anticoagulant (NOAC). We hypothesized that in clinical practice, VKAs may be prescribed less frequently to patients with AF and SAMe-TT2R2 scores &gt;2 than to patients with lower scores. Methods and results: We analyzed the Phase III dataset of the Global Registry on Long-Term Oral Antithrombotic Treatment in Patients with Atrial Fibrillation (GLORIA-AF), a large, global, prospective global registry of patients with newly diagnosed AF and ≥1 stroke risk factor. We compared baseline clinical characteristics and antithrombotic prescriptions to determine the probability of the VKA prescription among anticoagulated patients with the baseline SAMe-TT2R2 score &gt;2 and ≤ 2. Among 17,465 anticoagulated patients with AF, 4,828 (27.6%) patients were prescribed VKA and 12,637 (72.4%) patients an NOAC: 11,884 (68.0%) patients had SAMe-TT2R2 scores 0-2 and 5,581 (32.0%) patients had scores &gt;2. The proportion of patients prescribed VKA was 28.0% among patients with SAMe-TT2R2 scores &gt;2 and 27.5% in those with scores ≤2. Conclusions: The lack of a clear association between the SAMe-TT2R2 score and anticoagulant selection may be attributed to the relative efficacy and safety profiles between NOACs and VKAs as well as to the absence of trial evidence that an SAMe-TT2R2-guided strategy for the selection of the type of anticoagulation in NVAF patients has an impact on clinical outcomes of efficacy and safety. The latter hypothesis is currently being tested in a randomized controlled trial. Clinical trial registration: URL: https://www.clinicaltrials.gov//Unique identifier: NCT01937377, NCT01468701, and NCT01671007.</p

    The Changing Landscape for Stroke\ua0Prevention in AF: Findings From the GLORIA-AF Registry Phase 2

    Get PDF
    Background GLORIA-AF (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients with Atrial Fibrillation) is a prospective, global registry program describing antithrombotic treatment patterns in patients with newly diagnosed nonvalvular atrial fibrillation at risk of stroke. Phase 2 began when dabigatran, the first non\u2013vitamin K antagonist oral anticoagulant (NOAC), became available. Objectives This study sought to describe phase 2 baseline data and compare these with the pre-NOAC era collected during phase&nbsp;1. Methods During phase 2, 15,641 consenting patients were enrolled (November 2011 to December 2014); 15,092 were eligible. This pre-specified cross-sectional analysis describes eligible patients\u2019 baseline characteristics. Atrial fibrillation&nbsp;disease characteristics, medical outcomes, and concomitant diseases and medications were collected. Data were analyzed using descriptive statistics. Results Of the total patients, 45.5% were female; median age was 71 (interquartile range: 64, 78) years. Patients were from Europe (47.1%), North America (22.5%), Asia (20.3%), Latin America (6.0%), and the Middle East/Africa (4.0%). Most had high stroke risk (CHA2DS2-VASc [Congestive heart failure, Hypertension, Age&nbsp; 6575 years, Diabetes mellitus, previous Stroke, Vascular disease, Age 65 to 74 years, Sex category] score&nbsp; 652; 86.1%); 13.9% had moderate risk (CHA2DS2-VASc&nbsp;= 1). Overall, 79.9% received oral anticoagulants, of whom 47.6% received NOAC and 32.3% vitamin K antagonists (VKA); 12.1% received antiplatelet agents; 7.8% received no antithrombotic treatment. For comparison, the proportion of phase 1 patients (of N&nbsp;= 1,063 all eligible) prescribed VKA was 32.8%, acetylsalicylic acid 41.7%, and no therapy 20.2%. In Europe in phase 2, treatment with NOAC was more common than VKA (52.3% and 37.8%, respectively); 6.0% of patients received antiplatelet treatment; and 3.8% received no antithrombotic treatment. In North America, 52.1%, 26.2%, and 14.0% of patients received NOAC, VKA, and antiplatelet drugs, respectively; 7.5% received no antithrombotic treatment. NOAC use was less common in Asia (27.7%), where 27.5% of patients received VKA, 25.0% antiplatelet drugs, and 19.8% no antithrombotic treatment. Conclusions The baseline data from GLORIA-AF phase 2 demonstrate that in newly diagnosed nonvalvular atrial fibrillation patients, NOAC have been highly adopted into practice, becoming more frequently prescribed than VKA in&nbsp;Europe and North America. Worldwide, however, a large proportion of patients remain undertreated, particularly in&nbsp;Asia&nbsp;and North America. (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients With Atrial Fibrillation [GLORIA-AF]; NCT01468701

    Quality Controls in Digital Mammography protocol of the EFOMP Mammo Working group

    No full text
    This article aims to present the protocol on Quality Controls in Digital Mammography published online in 2015 by the European Federation of Organisations for Medical Physics (EFOMP) which was developed by a Task Force under the Mammo Working Group. The main objective of this protocol was to define a minimum set of easily implemented quality control tests on digital mammography systems that can be used to assure the performance of a system within a set and acceptable range. Detailed step-by-step instructions have been provided, limiting as much as possible any misinterpretations or variations by the person performing. It is intended that these tests be implemented as part of the daily routine of medical physicists and system users throughout Europe in a harmonised way so allowing results to be compared. In this paper the main characteristics of the protocol are illustrated, including examples, together with a brief summary of the contents of each chapter. Finally, instructions for the download of the full protocol and of the related software tools are provided

    Quality Controls in Digital Mammography protocol of the EFOMP Mammo Working group.

    No full text
    This article aims to present the protocol on Quality Controls in Digital Mammography published online in 2015 by the European Federation of Organisations for Medical Physics (EFOMP) which was developed by a Task Force under the Mammo Working Group. The main objective of this protocol was to define a minimum set of easily implemented quality control tests on digital mammography systems that can be used to assure the performance of a system within a set and acceptable range. Detailed step-by-step instructions have been provided, limiting as much as possible any misinterpretations or variations by the person performing. It is intended that these tests be implemented as part of the daily routine of medical physicists and system users throughout Europe in a harmonised way so allowing results to be compared. In this paper the main characteristics of the protocol are illustrated, including examples, together with a brief summary of the contents of each chapter. Finally, instructions for the download of the full protocol and of the related software tools are provided
    corecore