1,082 research outputs found
Double layer in ionic liquids: Overscreening vs. crowding
We develop a simple Landau-Ginzburg-type continuum theory of solvent-free
ionic liquids and use it to predict the structure of the electrical double
layer. The model captures overscreening from short-range correlations, dominant
at small voltages, and steric constraints of finite ion sizes, which prevail at
large voltages. Increasing the voltage gradually suppresses overscreening in
favor of the crowding of counterions in a condensed inner layer near the
electrode. The predicted ion profiles and capacitance-voltage relations are
consistent with recent computer simulations and experiments on room-temperature
ionic liquids, using a correlation length of order the ion size.Comment: 4 pages + supplementary informatio
Mitigating Ischemic Injury of Stem Cell-Derived Insulin-Producing Cells after Transplant.
The advent of large-scale in vitro differentiation of human stem cell-derived insulin-producing cells (SCIPC) has brought us closer to treating diabetes using stem cell technology. However, decades of experiences from islet transplantation show that ischemia-induced islet cell death after transplant severely limits the efficacy of the therapy. It is unclear to what extent human SCIPC are susceptible to ischemia. In this study, we show that more than half of SCIPC die shortly after transplantation. Nutrient deprivation and hypoxia acted synergistically to kill SCIPC in vitro. Amino acid supplementation rescued SCIPC from nutrient deprivation, likely by providing cellular energy. Generating SCIPC under physiological oxygen tension of 5% conferred hypoxia resistance without affecting their differentiation or function. A two-pronged strategy of physiological oxygen acclimatization during differentiation and amino acid supplementation during transplantation significantly improved SCIPC survival after transplant
Non-mean-field theory of anomalously large double-layer capacitance
Mean-field theories claim that the capacitance of the double-layer formed at
a metal/ionic conductor interface cannot be larger than that of the Helmholtz
capacitor, whose width is equal to the radius of an ion. However, in some
experiments the apparent width of the double-layer capacitor is substantially
smaller. We propose an alternate, non-mean-field theory of the ionic
double-layer to explain such large capacitance values. Our theory allows for
the binding of discrete ions to their image charges in the metal, which results
in the formation of interface dipoles. We focus primarily on the case where
only small cations are mobile and other ions form an oppositely-charged
background. In this case, at small temperature and zero applied voltage dipoles
form a correlated liquid on both contacts. We show that at small voltages the
capacitance of the double-layer is determined by the transfer of dipoles from
one electrode to the other and is therefore limited only by the weak
dipole-dipole repulsion between bound ions, so that the capacitance is very
large. At large voltages the depletion of bound ions from one of the capacitor
electrodes triggers a collapse of the capacitance to the much smaller
mean-field value, as seen in experimental data. We test our analytical
predictions with a Monte Carlo simulation and find good agreement. We further
argue that our ``one-component plasma" model should work well for strongly
asymmetric ion liquids. We believe that this work also suggests an improved
theory of pseudo-capacitance.Comment: 19 pages, 14 figures; some Monte Carlo results and a section about
aqueous solutions adde
Probing seed black holes using future gravitational-wave detectors
Identifying the properties of the first generation of seeds of massive black
holes is key to understanding the merger history and growth of galaxies.
Mergers between ~100 solar mass seed black holes generate gravitational waves
in the 0.1-10Hz band that lies between the sensitivity bands of existing
ground-based detectors and the planned space-based gravitational wave detector,
the Laser Interferometer Space Antenna (LISA). However, there are proposals for
more advanced detectors that will bridge this gap, including the third
generation ground-based Einstein Telescope and the space-based detector DECIGO.
In this paper we demonstrate that such future detectors should be able to
detect gravitational waves produced by the coalescence of the first generation
of light seed black-hole binaries and provide information on the evolution of
structure in that era. These observations will be complementary to those that
LISA will make of subsequent mergers between more massive black holes. We
compute the sensitivity of various future detectors to seed black-hole mergers,
and use this to explore the number and properties of the events that each
detector might see in three years of observation. For this calculation, we make
use of galaxy merger trees and two different seed black hole mass distributions
in order to construct the astrophysical population of events. We also consider
the accuracy with which networks of future ground-based detectors will be able
to measure the parameters of seed black hole mergers, in particular the
luminosity distance to the source. We show that distance precisions of ~30% are
achievable, which should be sufficient for us to say with confidence that the
sources are at high redshift.Comment: 14 pages, 6 figures, 2 tables, accepted for proceedings of 13th GWDAW
meetin
Strongly nonlinear dynamics of electrolytes in large ac voltages
We study the response of a model micro-electrochemical cell to a large ac
voltage of frequency comparable to the inverse cell relaxation time. To bring
out the basic physics, we consider the simplest possible model of a symmetric
binary electrolyte confined between parallel-plate blocking electrodes,
ignoring any transverse instability or fluid flow. We analyze the resulting
one-dimensional problem by matched asymptotic expansions in the limit of thin
double layers and extend previous work into the strongly nonlinear regime,
which is characterized by two novel features - significant salt depletion in
the electrolyte near the electrodes and, at very large voltage, the breakdown
of the quasi-equilibrium structure of the double layers. The former leads to
the prediction of "ac capacitive desalination", since there is a time-averaged
transfer of salt from the bulk to the double layers, via oscillating diffusion
layers. The latter is associated with transient diffusion limitation, which
drives the formation and collapse of space-charge layers, even in the absence
of any net Faradaic current through the cell. We also predict that steric
effects of finite ion sizes (going beyond dilute solution theory) act to
suppress the strongly nonlinear regime in the limit of concentrated
electrolytes, ionic liquids and molten salts. Beyond the model problem, our
reduced equations for thin double layers, based on uniformly valid matched
asymptotic expansions, provide a useful mathematical framework to describe
additional nonlinear responses to large ac voltages, such as Faradaic
reactions, electro-osmotic instabilities, and induced-charge electrokinetic
phenomena.Comment: 30 pages, 17 eps-figures, RevTe
Quantum noise in second generation, signal-recycled laser interferometric gravitational-wave detectors
It has long been thought that the sensitivity of laser interferometric
gravitational-wave detectors is limited by the free-mass standard quantum
limit, unless radical redesigns of the interferometers or modifications of
their input/output optics are introduced. Within a fully quantum-mechanical
approach we show that in a second-generation interferometer composed of arm
cavities and a signal recycling cavity, e.g., the LIGO-II configuration, (i)
quantum shot noise and quantum radiation-pressure-fluctuation noise are
dynamically correlated, (ii) the noise curve exhibits two resonant dips, (iii)
the Standard Quantum Limit can be beaten by a factor of 2, over a frequency
range \Delta f/f \sim 1, but at the price of increasing noise at lower
frequencies.Comment: 35 pages, 9 figures; few misprints corrected and some references
adde
Triple Michelson Interferometer for a Third-Generation Gravitational Wave Detector
The upcoming European design study `Einstein gravitational-wave Telescope'
represents the first step towards a substantial, international effort for the
design of a third-generation interferometric gravitational wave detector. It is
generally believed that third-generation instruments might not be installed
into existing infrastructures but will provoke a new search for optimal
detector sites. Consequently, the detector design could be subject to fewer
constraints than the on-going design of the second generation instruments. In
particular, it will be prudent to investigate alternatives to the traditional
L-shaped Michelson interferometer. In this article, we review an old proposal
to use three Michelson interferometers in a triangular configuration. We use
this example of a triple Michelson interferometer to clarify the terminology
and will put this idea into the context of more recent research on
interferometer technologies. Furthermore the benefits of a triangular detector
will be used to motivate this design as a good starting point for a more
detailed research effort towards a third-generation gravitational wave
detector.Comment: Minor corrections to the main text and two additional appendices. 14
pages, 6 figure
Fluorescence detection at the atom shot noise limit for atom interferometry
Atom interferometers are promising tools for precision measurement with
applications ranging from geophysical exploration to tests of the equivalence
principle of general relativity, or the detection of gravitational waves. Their
optimal sensitivity is ultimately limited by their detection noise. We review
resonant and near-resonant methods to detect the atom number of the
interferometer outputs and we theoretically analyze the relative influence of
various scheme dependent noise sources and the technical challenges affecting
the detection. We show that for the typical conditions under which an atom
interferometer operates, simultaneous fluorescence detection with a CCD sensor
is the optimal imaging scheme. We extract the laser beam parameters such as
detuning, intensity, and duration, required for reaching the atom shot noise
limit.Comment: 19 pages, 10 figure
Status of the GEO600 gravitational wave detector
The GEO600 laser interferometric gravitational wave detector is approaching the end of its commissioning phase which started in 1995.During a test run in January 2002 the detector was operated for 15 days in a power-recycled michelson configuration. The detector and environmental data which were acquired during this test run were used to test the data analysis code. This paper describes the subsystems of GEO600, the status of the detector by August 2002 and the plans towards the first science run
- …