78 research outputs found

    A point kernel algorithm for microbeam radiation therapy

    Get PDF

    Evaluation of inter- and intrafractional motion of liver tumors using interstitial markers and implantable electromagnetic radiotransmitters in the context of image-guided radiotherapy (IGRT) – the ESMERALDA trial

    Get PDF
    Background: With the development of more conformal and precise radiation techniques such as Intensity-Modulated Radiotherapy (IMRT), Stereotactic Body Radiotherapy (SBRT) and Image-Guided Radiotherapy (IGRT), patients with hepatic tumors could be treated with high local doses by sparing normal liver tissue. However, frequently occurring large HCC tumors are still a dosimetric challenge in spite of modern high sophisticated RT modalities. This interventional clinical study has been set up to evaluate the value of different fiducial markers, and to use the modern imaging methods for further treatment optimization using physical and informatics approaches. Methods and design: Surgically implanted radioopaque or electromagnetic markers are used to detect tumor local-ization during radiotherapy. The required markers for targeting and observation during RT can be implanted in a previously defined optimal position during the oncologically indicated operation. If there is no indication for a surgical resection or open biopsy, markers may be inserted into the liver or tumor tissue by using ultrasound-guidance. Primary study aim is the detection of the patients´ anatomy at the time of RT by observation of the marker position during the indicated irradiation (IGRT). Secondary study aims comprise detection and recording of 3D liver and tumor motion during RT. Furthermore, the study will help to develop technical strategies and mechanisms based on the recorded information on organ motion to avoid inaccurate dose application resulting from fast organ motion and deformation. Discussion: This is an open monocentric non-randomized, prospective study for the evaluation of organ motion using interstitial markers or implantable radiotransmitter. The trial will evaluate the full potential of different fiducial markers to further optimize treatment of moving targets, with a special focus on liver lesions

    Effect of MLC tracking latency on conformal volumetric modulated arc therapy (VMAT) plans in 4D stereotactic lung treatment

    Get PDF
    AbstractBackground and purposeThe latency of a multileaf collimator (MLC) tracking system used to overcome respiratory motion causes misalignment of the treatment beam with respect to the gross tumour volume, which may result in reduced target coverage. This study investigates the magnitude of this effect.Material and methodsSimulated superior–inferior breathing motion was used to construct histograms of isocentre offset with respect to the gross tumour volume (GTV) for a variety of tracking latencies. Dose distributions for conformal volumetric modulated arc therapy (VMAT) arcs were then calculated at a range of offsets and summed according to these displacement histograms. The results were verified by delivering the plans to a Delta4 phantom on a motion platform.ResultsIn the absence of an internal target margin, a tracking latency of 150ms reduces the GTV D95% by approximately 2%. With a margin of 2mm, the same drop in dose occurs for a tracking latency of 450ms. Lung V13Gy is unaffected by a range of latencies. These results are supported by the phantom measurements.ConclusionsAssuming that internal motion can be modelled by a rigid translation of the patient, MLC tracking of conformal VMAT can be effectively accomplished in the absence of an internal target margin for substantial breathing motion (4s period and 20mm peak–peak amplitude) so long as the system latency is less than 150ms

    Correction of patient positioning errors based on in-line cone beam CTs: clinical implementation and first experiences

    Get PDF
    BACKGROUND: The purpose of the study was the clinical implementation of a kV cone beam CT (CBCT) for setup correction in radiotherapy. PATIENTS AND METHODS: For evaluation of the setup correction workflow, six tumor patients (lung cancer, sacral chordoma, head-and-neck and paraspinal tumor, and two prostate cancer patients) were selected. All patients were treated with fractionated stereotactic radiotherapy, five of them with intensity modulated radiotherapy (IMRT). For patient fixation, a scotch cast body frame or a vacuum pillow, each in combination with a scotch cast head mask, were used. The imaging equipment, consisting of an x-ray tube and a flat panel imager (FPI), was attached to a Siemens linear accelerator according to the in-line approach, i.e. with the imaging beam mounted opposite to the treatment beam sharing the same isocenter. For dose delivery, the treatment beam has to traverse the FPI which is mounted in the accessory tray below the multi-leaf collimator. For each patient, a predefined number of imaging projections over a range of at least 200 degrees were acquired. The fast reconstruction of the 3D-CBCT dataset was done with an implementation of the Feldkamp-David-Kress (FDK) algorithm. For the registration of the treatment planning CT with the acquired CBCT, an automatic mutual information matcher and manual matching was used. RESULTS AND DISCUSSION: Bony landmarks were easily detected and the table shifts for correction of setup deviations could be automatically calculated in all cases. The image quality was sufficient for a visual comparison of the desired target point with the isocenter visible on the CBCT. Soft tissue contrast was problematic for the prostate of an obese patient, but good in the lung tumor case. The detected maximum setup deviation was 3 mm for patients fixated with the body frame, and 6 mm for patients positioned in the vacuum pillow. Using an action level of 2 mm translational error, a target point correction was carried out in 4 cases. The additional workload of the described workflow compared to a normal treatment fraction led to an extra time of about 10–12 minutes, which can be further reduced by streamlining the different steps. CONCLUSION: The cone beam CT attached to a LINAC allows the acquisition of a CT scan of the patient in treatment position directly before treatment. Its image quality is sufficient for determining target point correction vectors. With the presented workflow, a target point correction within a clinically reasonable time frame is possible. This increases the treatment precision, and potentially the complex patient fixation techniques will become dispensable

    Development of an anatomically correct mouse phantom for dosimetry measurement in small animal radiotherapy research

    Get PDF
    Significant improvements in radiotherapy are likely to come from biological rather than technical optimization, for example increasing tumour radiosensitivity via combination with targeted therapies. Such paradigms must first be evaluated in preclinical models for efficacy, and recent advances in small animal radiotherapy research platforms allow advanced irradiation protocols, similar to those used clinically, to be carried out in orthotopic models. Dose assessment in such systems is complex however, and a lack of established tools and methodologies for traceable and accurate dosimetry is currently limiting the capabilities of such platforms and slowing the clinical uptake of new approaches. Here we report the creation of an anatomically correct phantom, fabricated from materials with tissue-equivalent electron density, into which dosimetry detectors can be incorporated for measurement as part of quality control (QC). The phantom also allows training in preclinical radiotherapy planning and cross-institution validation of dose delivery protocols for small animal radiotherapy platforms without the need to sacrifice animals, with high reproducibility.Mouse CT data was acquired and segmented into soft tissue, bone and lung. The skeleton was fabricated using 3D printing, whilst lung was created using computer numerical control (CNC) milling. Skeleton and lung were then set into a surface-rendered mould and soft tissue material added to create a whole-body phantom. Materials for fabrication were characterized for atomic composition and attenuation for x-ray energies typically found in small animal irradiators. Finally cores were CNC milled to allow intracranial incorporation of bespoke detectors (alanine pellets) for dosimetry measurement

    A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy: A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking

    Get PDF
    AbstractPurposeA study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive radiotherapy in the presence of patient-measured tumor motion.Methods and materialsTen institutions with robotic(2), gimbaled(2), MLC(4) or couch tracking(2) used common materials including CT and structure sets, motion traces and planning protocols to create a lung and a prostate plan. For each motion trace, the plan was delivered twice to a moving dosimeter; with and without real-time adaptation. Each measurement was compared to a static measurement and the percentage of failed points for γ-tests recorded.ResultsFor all lung traces all measurement sets show improved dose accuracy with a mean 2%/2mm γ-fail rate of 1.6% with adaptation and 15.2% without adaptation (p<0.001). For all prostate the mean 2%/2mm γ-fail rate was 1.4% with adaptation and 17.3% without adaptation (p<0.001). The difference between the four systems was small with an average 2%/2mm γ-fail rate of <3% for all systems with adaptation for lung and prostate.ConclusionsThe investigated systems all accounted for realistic tumor motion accurately and performed to a similar high standard, with real-time adaptation significantly outperforming non-adaptive delivery methods

    Intensity-modulated radiotherapy of nasopharyngeal carcinoma: a comparative treatment planning study of photons and protons

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this treatment planning study was to investigate the potential advantages of intensity-modulated (IM) proton therapy (IMPT) compared with IM photon therapy (IMRT) in nasopharyngeal carcinoma (NPC).</p> <p>Methods</p> <p>Eight NPC patients were chosen. The dose prescriptions in cobalt Gray equivalent (Gy<sub>E</sub>) for gross tumor volumes of the primary tumor (GTV-T), planning target volumes of GTV-T and metastatic (PTV-TN) and elective (PTV-N) lymph node stations were 72.6 Gy<sub>E</sub>, 66 Gy<sub>E</sub>, and 52.8 Gy<sub>E</sub>, respectively. For each patient, nine coplanar fields IMRT with step-and-shoot technique and 3D spot-scanned three coplanar fields IMPT plans were prepared. Both modalities were planned in 33 fractions to be delivered with a simultaneous integrated boost technique. All plans were prepared and optimized by using the research version of the inverse treatment planning system KonRad (DKFZ, Heidelberg).</p> <p>Results</p> <p>Both treatment techniques were equal in terms of averaged mean dose to target volumes. IMPT plans significantly improved the tumor coverage and conformation (<it>P </it>< 0.05) and they reduced the averaged mean dose to several organs at risk (OARs) by a factor of 2–3. The low-to-medium dose volumes (0.33–13.2 Gy<sub>E</sub>) were more than doubled by IMRT plans.</p> <p>Conclusion</p> <p>In radiotherapy of NPC patients, three-field IMPT has greater potential than nine-field IMRT with respect to tumor coverage and reduction of the integral dose to OARs and non-specific normal tissues. The practicality of IMPT in NPC deserves further exploration when this technique becomes available on wider clinical scale.</p