10 research outputs found

    Visually assessed breast density, breast cancer risk and the importance of the craniocaudal view

    Get PDF
    Contains fulltext : 69403.pdf (publisher's version ) (Open Access)INTRODUCTION: Mammographic density is known to be a strong risk factor for breast cancer. A particularly strong association with risk has been observed when density is measured using interactive threshold software. This, however, is a labour-intensive process for large-scale studies. METHODS: Our aim was to determine the performance of visually assessed percent breast density as an indicator of breast cancer risk. We compared the effect on risk of density as measured with the mediolateral oblique view only versus that estimated as the average density from the mediolateral oblique view and the craniocaudal view. Density was assessed using a visual analogue scale in 10,048 screening mammograms, including 311 breast cancer cases diagnosed at that screening episode or within the following 6 years. RESULTS: Where only the mediolateral oblique view was available, there was a modest effect of breast density on risk with an odds ratio for the 76% to 100% density relative to 0% to 25% of 1.51 (95% confidence interval 0.71 to 3.18). When two views were available, there was a considerably stronger association, with the corresponding odds ratio being 6.77 (95% confidence interval 2.75 to 16.67). CONCLUSION: This indicates that a substantial amount of information on risk from percentage breast density is contained in the second view. It also suggests that visually assessed breast density has predictive potential for breast cancer risk comparable to that of density measured using the interactive threshold software when two views are available. This observation needs to be confirmed by studies applying the different measurement methods to the same individuals

    A comparison of five methods of measuring mammographic density: a case-control study.

    Get PDF
    BACKGROUND: High mammographic density is associated with both risk of cancers being missed at mammography, and increased risk of developing breast cancer. Stratification of breast cancer prevention and screening requires mammographic density measures predictive of cancer. This study compares five mammographic density measures to determine the association with subsequent diagnosis of breast cancer and the presence of breast cancer at screening. METHODS: Women participating in the "Predicting Risk Of Cancer At Screening" (PROCAS) study, a study of cancer risk, completed questionnaires to provide personal information to enable computation of the Tyrer-Cuzick risk score. Mammographic density was assessed by visual analogue scale (VAS), thresholding (Cumulus) and fully-automated methods (Densitas, Quantra, Volpara) in contralateral breasts of 366 women with unilateral breast cancer (cases) detected at screening on entry to the study (Cumulus 311/366) and in 338 women with cancer detected subsequently. Three controls per case were matched using age, body mass index category, hormone replacement therapy use and menopausal status. Odds ratios (OR) between the highest and lowest quintile, based on the density distribution in controls, for each density measure were estimated by conditional logistic regression, adjusting for classic risk factors. RESULTS: The strongest predictor of screen-detected cancer at study entry was VAS, OR 4.37 (95% CI 2.72-7.03) in the highest vs lowest quintile of percent density after adjustment for classical risk factors. Volpara, Densitas and Cumulus gave ORs for the highest vs lowest quintile of 2.42 (95% CI 1.56-3.78), 2.17 (95% CI 1.41-3.33) and 2.12 (95% CI 1.30-3.45), respectively. Quantra was not significantly associated with breast cancer (OR 1.02, 95% CI 0.67-1.54). Similar results were found for subsequent cancers, with ORs of 4.48 (95% CI 2.79-7.18), 2.87 (95% CI 1.77-4.64) and 2.34 (95% CI 1.50-3.68) in highest vs lowest quintiles of VAS, Volpara and Densitas, respectively. Quantra gave an OR in the highest vs lowest quintile of 1.32 (95% CI 0.85-2.05). CONCLUSIONS: Visual density assessment demonstrated a strong relationship with cancer, despite known inter-observer variability; however, it is impractical for population-based screening. Percentage density measured by Volpara and Densitas also had a strong association with breast cancer risk, amongst the automated measures evaluated, providing practical automated methods for risk stratification

    Mammographic density adds accuracy to both the Tyrer-Cuzick and Gail breast cancer risk models in a prospective UK screening cohort

    Get PDF
    This work was supported by the National Institute for Health Research (NIHR) and Genesis Breast Cancer Prevention Appeal (references GA10-033 and GA13-006). This article presents independent research funded by the NIHR under its Programme Grants for Applied Research (grant RP-PG-0707-10031). The views expressed are those of the authors and not necessarily those of the NHS, the NIHR or the Department of Health. The authors also acknowledge the support of Medical Research Council Health eResearch Centre grant MR/K006665/1
    corecore