2,564 research outputs found

    Analytical and experimental investigation of flow fields of annular jets with and without swirling flow

    Get PDF
    Analytical and experimental studies were performed to define the flowfield of annular jets, with and, without swirling flow. The analytical model treated configurations with variations of flow angularities, radius ratio, and swirl distributions. Swirl distributions characteristic of stator vanes and rotor blade rows, where the total pressure and swirl distributions are related were incorporated in the mathematical model. The experimental studies included tests of eleven nozzle models, both with and, without swirling exhaust flow. Flowfield surveys were obtained and used for comparison with the analytical model. This comparison of experimental and analytical studies served as the basis for evaluation of several empirical constants as required for application of the analysis to the general flow configuration. The analytical model developed during these studies is applicable to the evaluation of the flowfield and overall performance of the exhaust of statorless lift fan systems that contain various levels of exhaust swirl

    Editorial

    Get PDF

    Design, fabrication and acoustic tests of a 36 inch (0.914 meter) statorless turbotip fan

    Get PDF
    The LF336/E is a 36 inch (0.914 meter) diameter fan designed to operate in a rotor-alone configuration. Design features required for modification of the existing LF336/A rotor-stator fan into the LF336/E statorless fan configuration are discussed. Tests of the statorless fan identified an aerodynamic performance deficiency due to inaccurate accounting of the fan exit swirl during the aerodynamic design. This performance deficiency, related to fan exit static pressure levels, produced about a 20 percent thrust loss. A study was then conducted for further evaluation of the fan exit flow fields typical of statorless fan systems. This study showed that through proper selection of fan design variables such as pressure ratio, radius ratio, and swirl distributions, performance of a statorless fan configuration could be improved with levels of thrust approaching the conventional rotor-stator fan system. Acoustic measurements were taken for the statorless fan system at both GE and NASA, and when compared to other lift fan systems, showed noise levels comparable to the quietest lift fan configuration which included rotor-stator spacing and acoustic treatment. The statorless fan system was also used to determine effects of rotor leading edge serrations on noise generations. A cascade test program identified the serration geometry based on minimum pressure losses, wake turbulence levels and noise generations

    Technical analysis: Novel insights on contrarian trading

    Full text link
    We analyze the predictive power of technical analysis with a novel data set based on news sentiment that allows to systematically examine a set of technical analysis indicators over an extensive time period. We do not find much statistically significant relationships with the examined indicators and future asset returns, and we almost do not find any alphas in trading strategies based on technical analysis sentiment. We find evidence for a contrarian-based hypothesis: past market returns and technical analysis sentiment are able to predict future technical analysis sentiment with a negative relationship

    Triple correlation for detection of damage-related nonlinearities in composite structures

    Get PDF
    Nonlinear effects in vibration responses are investigated for the undamaged composite plate and the composite plate with a delamination. The analysis is focused on higher harmonic generation in vibration responses for various excitation amplitude levels. This effect is investigated using the triple correlation technique. The dynamics of composite plate was modelled using two-dimensional finite elements and the classical lamination theory. The doubled-node approach was used to model delamination area. Mode shapes and natural frequencies were estimated based on numerical models. Next, the delamination divergence analysis was used to obtain relative displacements for delaminated plies. Experimental modal analysis test was carried out to verify the numerical models. The two strongest vibration modes as well as two vibration modes with the smallest and largest motion level of delaminated plies were selected for nonlinear vibration test. The Fisher criterion was employed to verify the effectiveness and confidence level of the proposed technique. The results show that the method can be used not only to reveal nonlinearities, but also to reliably detect impact damage in composites. These results are confirmed using the statistical analysis

    Treatment of complicated intra-abdominal infections in the era of multi-drug resistant bacteria

    Get PDF
    The management of severe intra-abdominal infections remains a major challenge facing surgeons and intensive care physicians, because of its association with high morbidity and mortality. Surgical management and intensive care medicine have constantly improved, but in the recent years a rapidly continuing emergence of resistant pathogens led to treatment failure secondary to infections with multi-drug resistant bacteria. In secondary peritonitis the rate of resistant germs at the initial operation is already 30%. The lack of effective antibiotics against these pathogens resulted in the development of new broad-spectrum compounds and antibiotics directed against resistant germs. But so far no "super-drug" with efficacy against all resistant bacteria exists. Even more, soon after their approval, reports on resistance against these novel drugs have been reported, or the drugs were withdrawn from the market due to severe side effects. Since pharmaceutical companies reduced their investigations on antibiotic research, only few new antimicrobial derivates are available

    Post-Operative Rehabilitation for Scapular Muscle Reattachment: A Case Report

    Get PDF
    Background and Purpose: Scapular muscle detachment is a rare orthopedic problem that has been described in the literature in patients following traumatic events involving traction, direct trauma, or a motor vehicle accident. The purpose of this case report is to describe the post-operative rehabilitation following scapular muscle reattachment surgery. Unique to this case report is the patient\u27s perspective, an orthopedic physical therapist with 25 years of experience. Case Description: A 47-year-old female physical therapist experienced a traction injury to bilateral upper extremities during a medical procedure resulting in bilateral rhomboid, and bilateral lower trapezius muscles were detached from the medial scapular border. Reconstruction of the left scapulothoracic musculature occurred five and one-half years post-injury with the right repaired one year later. This case report describes the rehabilitation program that took one-year to recover for each arm with a period of protected motion for 16-weeks and gradual return to function as a manual physical therapist over a period of one-year. Outcomes: The American Shoulder and Elbow Surgeons (ASES) Standardized Assessment Form and pain-free range of motion was used pre- and postoperatively. Left and right shoulder pre-operative ASES scores were 68 and 72, respectively. At the one-year post-operative the left shoulder was rated at 82 and the right shoulder was 90. Pain-free range of motion was achieved in both arms by one year. Functional limitations requiring strength overhead were the slowest to return and were not completely back at one year following either surgery. Discussion: Rehabilitation protocols for scapular muscle reattachment surgery are not commonly available to allow physical therapists to guide their patients and structure a rehabilitation program. This case report provides a sample pre-operative set of educational guidelines and a post-operative protocol for use after scapular reattachment surgery. This case report is unique because it offers a patient perspective who is a physical therapist and underwent this surgery twice. Therefore, providing insight on how to prepare for such a unique operation. The slow recovery is due to three issues 1) the prolonged time from injury to diagnosis created significant muscle wasting and muscular imbalance of surrounding tissues, 2) once this tissue was repaired it requires months of protection to recover, 3) the involved scapulothoracic muscle have to regain adequate strength as the foundation for upper extremity functions. Level of evidence: Level 5
    corecore