1,296 research outputs found

    Comment on ``Lyapunov Exponent of a Many Body System and Its Transport Coefficients''

    Full text link
    In a recent Letter, Barnett, Tajima, Nishihara, Ueshima and Furukawa obtained a theoretical expression for the maximum Lyapunov exponent λ1\lambda_1 of a dilute gas. They conclude that λ1\lambda_1 is proportional to the cube root of the self-diffusion coefficient DD, independent of the range of the interaction potential. They validate their conjecture with numerical data for a dense one-component plasma, a system with long-range forces. We claim that their result is highly non-generic. We show in the following that it does not apply to a gas of hard spheres, neither in the dilute nor in the dense phase.Comment: 1 page, Revtex - 1 PS Figs - Submitted to Physical Review Letter

    Ectopic cardiovascular fat in middle-aged men: effects of race/ethnicity, overall and central adiposity. The ERA JUMP study.

    Get PDF
    Background/objectivesHigher volumes of ectopic cardiovascular fat (ECF) are associated with greater risk of coronary heart disease (CHD). Identifying factors that are associated with ECF volumes may lead to new preventive efforts to reduce risk of CHD. Significant racial/ethnic differences exist for overall and central adiposity measures, which are known to be associated with ECF volumes. Whether racial/ethnic differences also exist for ECF volumes and their associations with these adiposity measures remain unclear.Subjects/methodsBody mass index (BMI), computerized tomography-measured ECF volumes (epicardial, pericardial and their summation) and visceral adipose tissue (VAT) were examined in a community-based sample of 1199 middle-aged men (24.2% Caucasians, 7.0% African-Americans, 23.6% Japanese-Americans, 22.0% Japanese, 23.2% Koreans).ResultsSignificant racial/ethnic differences existed in ECF volumes and their relationships with BMI and VAT. ECF volumes were the highest among Japanese-Americans and the lowest among African-Americans. The associations of BMI and VAT with ECF differed by racial/ethnic groups. Compared with Caucasians, for each 1-unit increase in BMI, African-Americans had lower, whereas Koreans had higher increases in ECF volumes (P-values<0.05 for both). Meanwhile, compared with Caucasians, for each 1-unit increase in log-transformed VAT, African-Americans, Japanese-Americans and Japanese had similar increases, whereas Koreans had a lower increase in ECF volumes (P-value<0.05).ConclusionsRacial/ethnic groups differed in their propensity to accumulate ECF at increasing level of overall and central adiposity. Future studies should evaluate whether reducing central adiposity or overall weight will decrease ECF volumes more in certain racial/ethnic groups. Evaluating these questions might help in designing race-specific prevention strategy of CHD risk associated with higher ECF

    Multiphoton radiative recombination of electron assisted by laser field

    Get PDF
    In the presence of an intensive laser field the radiative recombination of the continuum electron into an atomic bound state generally is accompanied by absorption or emission of several laser quanta. The spectrum of emitted photons represents an equidistant pattern with the spacing equal to the laser frequency. The distribution of intensities in this spectrum is studied employing the Keldysh-type approximation, i.e. neglecting interaction of the impact electron with the atomic core in the initial continuum state. Within the adiabatic approximation the scale of emitted photon frequencies is subdivided into classically allowed and classically forbidden domains. The highest intensities correspond to emission frequencies close to the edges of classically allowed domain. The total cross section of electron recombination summed over all emitted photon channels exhibits negligible dependence on the laser field intensity.Comment: 14 pages, 5 figures (Figs.2-5 have "a" and "b" parts), Phys.Rev.A accepted for publication. Fig.2b is presented correctl

    White paper: CeLAND - Investigation of the reactor antineutrino anomaly with an intense 144Ce-144Pr antineutrino source in KamLAND

    Full text link
    We propose to test for short baseline neutrino oscillations, implied by the recent reevaluation of the reactor antineutrino flux and by anomalous results from the gallium solar neutrino detectors. The test will consist of producing a 75 kCi 144Ce - 144Pr antineutrino source to be deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND). KamLAND's 13m diameter target volume provides a suitable environment to measure energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, "sterile" state. Such a measurement will be free of any reactor-related uncertainties. After 1.5 years of data taking the Reactor Antineutrino Anomaly parameter space will be tested at > 95% C.L.Comment: White paper prepared for Snowmass-2013; slightly different author lis

    Measurement of the double-\beta decay half-life of ^{136}Xe with the KamLAND-Zen experiment

    Full text link
    We present results from the KamLAND-Zen double-beta decay experiment based on an exposure of 77.6 days with 129 kg of 136^{136}Xe. The measured two-neutrino double-beta decay half-life of 136^{136}Xe is T1/22ν=2.38±0.02(stat)±0.14(syst)×1021T_{1/2}^{2\nu} = 2.38 \pm 0.02(stat) \pm 0.14(syst) \times 10^{21} yr, consistent with a recent measurement by EXO-200. We also obtain a lower limit for the neutrinoless double-beta decay half-life, T1/20ν>5.7×1024T_{1/2}^{0\nu} > 5.7 \times 10^{24} yr at 90% confidence level (C.L.), which corresponds to almost a five-fold improvement over previous limits.Comment: 6 pages, 4 figures. Version as published in PR

    A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector

    Full text link
    We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. An infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable's motion, and the system was controlled via a graphical user interface.Comment: Revised author affiliations, corrected typos, made minor improvements to text, and revised reference

    Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon

    Full text link
    In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2 0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to 7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee for a scintillation light yield of 20.9 p.e./keV. Further study was done by masking some of that light to reduce this yield to 4.6 p.e./keV, the same method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3 0.2(sys)\times10-1 for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the fluctuations in our early to total ratio for electron events are larger than expected from statistical fluctuations.Comment: 25 pages, 15 figure

    Self-shielding effect of a single phase liquid xenon detector for direct dark matter search

    Full text link
    Liquid xenon is a suitable material for a dark matter search. For future large scale experiments, single phase detectors are attractive due to their simple configuration and scalability. However, in order to reduce backgrounds, they need to fully rely on liquid xenon's self-shielding property. A prototype detector was developed at Kamioka Observatory to establish vertex and energy reconstruction methods and to demonstrate the self-shielding power against gamma rays from outside of the detector. Sufficient self-shielding power for future experiments was obtained.Comment: 8 pages, 8 figure
    corecore