498 research outputs found

    Genome Sequence of Stenotrophomonas maltophilia PML168, Which Displays Baeyer-Villiger Monooxygenase Activity

    Get PDF
    Stenotrophomonas maltophilia PML168 was isolated from Wembury Beach on the English Coast from a rock pool following growth and selection on agar plates. Here we present the permanent draft genome sequence, which has allowed prediction of function for several genes encoding enzymes relevant to industrial biotechnology, including a novel flavoprotein monooxygenase

    The emergence of international food safety standards and guidelines: understanding the current landscape through a historical approach

    Get PDF
    Following the Second World War, the Food and Agriculture Organization (FAO) and the World Health Organization (WHO) teamed up to construct an International Codex Alimentarius (or 'food code') which emerged in 1963. The Codex Committee on Food Hygiene (CCFH) was charged with the task of developing microbial hygiene standards, although it found itself embroiled in debate with the WHO over the nature these standards should take. The WHO was increasingly relying upon the input of biometricians and especially the International Commission on Microbial Specifications for Foods (ICMSF) which had developed statistical sampling plans for determining the microbial counts in the final end products. The CCFH, however, was initially more focused on a qualitative approach which looked at the entire food production system and developed codes of practice as well as more descriptive end-product specifications which the WHO argued were 'not scientifically correct'. Drawing upon historical archival material (correspondence and reports) from the WHO and FAO, this article examines this debate over microbial hygiene standards and suggests that there are many lessons from history which could shed light upon current debates and efforts in international food safety management systems and approaches

    Affordable flow cytometry for enumeration of absolute CD4(+ )T-lymphocytes to identify subtype C HIV-1 infected adults requiring antiretroviral therapy (ART) and monitoring response to ART in a resource-limited setting

    Get PDF
    BACKGROUND: The World Health Organization (WHO)'s "3 × 5 program" has spurred efforts to place 3 million people on combination antiretroviral therapy (ART) for treatment of AIDS in resource-limited countries. Paradoxically, the cost of CD4(+ )T-lymphocyte count essential for decision-making to commence HIV positive adults on ART as well as for monitoring responses to ART remains unaffordable in most resource-limited countries. Thus, low-cost methods for enumerating CD4(+ )T-lymphocyte are urgently needed. OBJECTIVE: To evaluate Cyflow cytometry (Cyflow SL, Partec, Munster, Germany) for enumeration of absolute CD4(+ )T-lymphocyte in subtype C HIV-1 seropositive subjects using FACSCount (Becton and Dickinson, Immunocytometry Systems, San Jose, CA, USA) as the "predicate method". METHODS: A total of 150 HIV-1 seropositive subjects were included in the evaluation exercise. Fifty-eight specimens were collected from pregnant HIV-1 seropositive women (subtype C drug resistance study). Twenty-seven specimens were collected from women and their spouses with AIDS followed in a Duke ART study to assess the immunologic and virologic responses to generic ART, comprising Stavudine, Lamivudine and Nevirapine (Stalanev, Varichem Labs, Harare, Zimbabwe). Sixty-five specimens were collected from AIDS patients enrolled in an ongoing Kaposi Sarcoma (KS) study to investigate impact of ART on KS progression. Enumeration of CD4(+ )T-lymphocytes using FACSCount is routinely conducted for all the three studies. The Medical Research Council of Zimbabwe and Medicines Control Authority of Zimbabwe approved the studies. Whole blood was collected in EDTA vacutainer tubes and aliquoted into two tubes (200 μL in each). CD4(+ )T-lymphocyte counts were enumerated using a Cyflow counter, in the Department of Immunology and a FACSCount in the Department of Obstetrics and Gynaecology within 6 hours of phlebotomy following manufacturers' instructions. RESULTS: Using linear regression analysis, there was a very strong correlation (R = 0.991) between the overall CD4(+ )T-lymphocyte counts obtained by FACSCount and those obtained by Cyflow. When data analysis was stratified by study groups, there was a strong correlation between the FACSCount and Cyflow CD4(+ )T-lymphocyte counts from subjects in the three independent studies; Subtype C resistance (R(2 )= 0.987), Duke ART (R(2 )= 0.980) and KS (R(2 )= 0.994), Table 1. Using Bland-Altman plots, the overall, absolute CD4(+ )T lymphocytes obtained by the two methods were in excellent agreement (mean difference 1.21, 95% Confidence Interval {CI): -2.1 to 3.3). For the 0–250 CD4(+ )T-lymphocytes range, the CD4 counts obtained using FACSCount were also in good agreement with those obtained using Cyflow counter (mean difference = 2.6 cells/μL, 95% CI: -1.1 to 6.3). Similarly, in the 251–500 (mean difference 1.0, cells/μL, 95% CI: -3.7 to 5.6) and the 501–1200 (mean difference = 0.29 cells/μL, 95% CI: -8.1 to 8.7) CD4 T-lymphocytes range, good agreement was observed. CONCLUSION: The Cyflow counter is as accurate as the FACSCount in enumerating absolute CD4(+ )T-lymphocytes in the range 1–1200 cells/μL. Cyflow cytometry is relatively affordable, easy to use technology that is useful not only in identifying HIV seropositive individuals who require ART but also for monitoring immunologic responses to ART

    Choriocarcinoma in a 73-year-old woman: a case report and review of the literature

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Choriocarcinoma is a highly malignant tumor of trophoblastic origin. Most cases present within one year of the antecedent pregnancy (molar or non-molar). However, very rarely, choriocarcinoma can develop from germ cells or from dedifferentiation of endometrial carcinoma into choriocarcinoma. This article concerns a case of choriocarcinoma developing 38 years after the patient's last pregnancy and 23 years after menopause.</p> <p>Case presentation</p> <p>A 73-year-old African-American woman presented with a three-week history of vaginal bleeding. A vaginal mass was seen on pelvic examination. Ultrasonography showed a thickened complex endometrial echo. Her β-human chorionic gonadotrophin level was found to be elevated (2,704,040 mIU/mL). Vaginal and uterine biopsies were suggestive of choriocarcinoma. Immunohistochemistry tests were positive for β-human chorionic gonadotrophin as well as cytokeratin and negative for octamer binding transcription factor 3/4 and α-fetoprotein, supporting the diagnosis of choriocarcinoma. A combination of etoposide, methotrexate, and dactinomycin, followed by cyclophosphamide and vincristine (the so-called EMA/CO regimen) was initiated. After seven cycles of chemotherapy, her β-human chorionic gonadotrophin level dropped below 5 mIU/mL. Our patient is being followed up at our oncology institute.</p> <p>Conclusions</p> <p>We report an extremely rare case of choriocarcinoma arising 23 years after menopause. A postmenopausal woman presenting with vaginal bleed from a mass and β-human chorionic gonadotrophin elevation should be evaluated by immunohistochemical analysis to rule out the possibilities of a germ cell origin of the tumor or dedifferentiation of an epithelial tumor. Absence of octamer binding transcription factor 3/4, α-fetoprotein and CD-30 staining helps in exclusion of most germ cell tumors. DNA polymorphism studies can be used to differentiate between gestational and non-gestational tumor origin. These require fresh tissue samples and are time consuming. Finally, the effective first-line therapy for β-human chorionic gonadotrophin-producing high-risk gestational as well as non-gestational trophoblastic tumors is combination chemotherapy (the EMA/CO regimen). Therefore, treatment should be commenced when a potential diagnosis of metastatic trophoblastic tumor is being considered.</p

    Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    Get PDF
    BACKGROUND: Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. METHODS: Five rapid HIV assays: Determine HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). RESULTS: Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9), respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold, Determine and SD Bioline assays. CONCLUSION: An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1-100) and 100% specificity (95% CI; 96-99.1) with Uni-Gold as tiebreaker for discordant results

    Sodium ion interactions with aqueous glucose: Insights from quantum mechanics, molecular dynamics, and experiment

    Get PDF
    In the last several decades, significant efforts have been conducted to understand the fundamental reactivity of glucose derived from plant biomass in various chemical environments for conversion to renewable fuels and chemicals. For reactions of glucose in water, it is known that inorganic salts naturally present in biomass alter the product distribution in various deconstruction processes. However, the molecular-level interactions of alkali metal ions and glucose are unknown. These interactions are of physiological interest as well, for example, as they relate to cation-glucose cotransport. Here, we employ quantum mechanics (QM) to understand the interaction of a prevalent alkali metal, sodium, with glucose from a structural and thermodynamic perspective. The effect on B-glucose is subtle: a sodium ion perturbs bond lengths and atomic partial charges less than rotating a hydroxymethyl group. In contrast, the presence of a sodium ion significantly perturbs the partial charges of α-glucose anomeric and ring oxygens. Molecular dynamics (MD) simulations provide dynamic sampling in explicit water, and both the QM and the MD results show that sodium ions associate at many positions with respect to glucose with reasonably equivalent propensity. This promiscuous binding nature of Na + suggests that computational studies of glucose reactions in the presence of inorganic salts need to ensure thorough sampling of the cation positions, in addition to sampling glucose rotamers. The effect of NaCl on the relative populations of the anomers is experimentally quantified with light polarimetry. These results support the computational findings that Na + interacts similarly with a- and B-glucose
    corecore