1,971 research outputs found

    Hafnium carbide formation in oxygen deficient hafnium oxide thin films

    Full text link
    On highly oxygen deficient thin films of hafnium oxide (hafnia, HfO2x_{2-x}) contaminated with adsorbates of carbon oxides, the formation of hafnium carbide (HfCx_x) at the surface during vacuum annealing at temperatures as low as 600 {\deg}C is reported. Using X-ray photoelectron spectroscopy the evolution of the HfCx_x surface layer related to a transformation from insulating into metallic state is monitored in situ. In contrast, for fully stoichiometric HfO2_2 thin films prepared and measured under identical conditions, the formation of HfCx_x was not detectable suggesting that the enhanced adsorption of carbon oxides on oxygen deficient films provides a carbon source for the carbide formation. This shows that a high concentration of oxygen vacancies in carbon contaminated hafnia lowers considerably the formation energy of hafnium carbide. Thus, the presence of a sufficient amount of residual carbon in resistive random access memory devices might lead to a similar carbide formation within the conducting filaments due to Joule heating

    Evaluation of two thermal neutron detection units consisting of ZnS/6{}^6LiF scintillating layers with embedded WLS fibers read out with a SiPM

    Full text link
    Two single channel detection units for thermal neutron detection are investigated in a neutron beam. They consist of two ZnS/6{}^6LiF scintillating layers sandwiching an array of WLS fibers. The pattern of this units can be repeated laterally and vertically in order to build up a one dimensional position sensitive multi-channel detector with the needed sensitive surface and with the required neutron absorption probability. The originality of this work arises from the fact that the WLS fibers are read out with SiPMs instead of the traditionally used PMTs or MaPMTs. The signal processing system is based on a photon counting approach. For SiPMs with a dark count rate as high as 0.7 MHz, a trigger efficiency of 80% is achieved together with a system background rate lower than 103{10}^{-3} Hz and a dead time of 30 μ\mus. No change of performance is observed for neutron count rates of up to 3.6 kHz.Comment: Submitted to Nuclear Instruments and Methods

    Complex span versus updating tasks of working memory : the gap is not that deep

    No full text
    How to best measure working memory capacity is an issue of ongoing debate. Besides established complex span tasks, which combine short-term memory demands with generally unrelated secondary tasks, there exists a set of paradigms characterized by continuous and simultaneous updating of several items in working memory, such as the n-back, memory updating, or alpha span tasks. With a latent variable analysis (N = 96) based on content-heterogeneous operationalizations of both task families, the authors found a latent correlation between a complex span factor and an updating factor that was not statistically different from unity (r = .96). Moreover, both factors predicted fluid intelligence (reasoning) equally well. The authors conclude that updating tasks measure working memory equally well as complex span tasks. Processes involved in building, maintaining, and updating arbitrary bindings may constitute the common working memory ability underlying performance on reasoning, complex span, and updating tasks

    Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the Inner Tracking System of HERA-B

    Get PDF
    The results of five years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about 20 * 20 cm2 each. The detector is based on microstrip gas counters (MSGCs) with diamond like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step. Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar-DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO2 showed no serious aging effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000.Comment: 29 pages, 22 figure
    corecore