60 research outputs found

    Weight gain associated with integrase stand transfer inhibitor use in women

    Get PDF
    Background. Integrase strand-transfer inhibitor (INSTI)-based antiretroviral therapy (ART) is recommended for human immunodeficiency virus (HIV) management. Although studies have suggested associations between INSTIs and weight gain, women living with HIV (WLHIV) have been underrepresented in research. We evaluated the effect of switching or adding INSTIs among WLHIV. Methods. Women enrolled in the Women's Interagency HIV Study (WIHS) from 2006-2017 who switched to or added an INSTI to ART (SWAD group) were compared to women on non-INSTI ART (STAY group). Body weight, body mass index (BMI), percentage body fat (PBF), and waist, hip, arm, and thigh circumferences were measured 6-12 months before and 6-18 months after the INSTI switch/add in SWAD participants, with comparable measurement time points in STAY participants. Linear regression models compared changes over time by SWAD/STAY group, adjusted for age, race, WIHS site, education, income, smoking status, and baseline ART regimen. Results. We followed 1118 women (234 SWAD and 884 STAY) for a mean of 2.0 years (+/- 0.1 standard deviation [SD]; mean age 48.8 years, SD +/- 8.8); 61% were Black. On average, compared to the STAY group, the SWAD group experienced mean greater increases of 2.1 kg in body weight, 0.8 kg/m2 in BMI, 1.4% in PBF, and 2.0, 1.9, 0.6, and 1.0 cm in waist, hip, arm, and thigh circumference, respectively (all P values < .05). No differences in magnitudes of these changes were observed by INSTI type. Conclusions. In WLHIV, a switch to INSTI was associated with significant increases in body weight, body circumferences, and fat percentages, compared to non-INSTI ART. The metabolic and other health effects of these changes deserve further investigation

    Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach.</p> <p>Methods</p> <p>A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009.</p> <p>Results</p> <p>Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for a benign finding seen on the original ultrasound-guided diagnostic breast biopsy procedure.</p> <p>Conclusions</p> <p>In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information.</p

    Effect of nitrate supply and mycorrhizal inoculation on characteristics of tobacco root plasma membrane vesicles

    Get PDF
    Plant plasma membrane (pm) vesicles from mycorrhizal tobacco (Nicotiana tabacum cv. Samsun) roots were isolated with negligible fungal contamination by the aqueous two-phase partitioning technique as proven by fatty acid analysis. Palmitvaccenic acid became apparent as an appropriate indicator for fungal membranes in root pm preparations. The pm vesicles had a low specific activity of the vanadate-sensitive ATPase and probably originated from non-infected root cells. In a phosphate-limited tobacco culture system, root colonisation by the vesicular arbuscular mycorrhizal fungus, Glomus mosseae, is inhibited by external nitrate in a dose-dependent way. However, detrimental high concentrations of 25 mM nitrate lead to the highest colonisation rate observed, indicating that the defence system of the plant is impaired. Nitric oxide formation by the pm-bound nitrite:NO reductase increased in parallel with external nitrate supply in mycorrhizal roots in comparison to the control plants, but decreased under excess nitrate. Mycorrhizal pm vesicles had roughly a twofold higher specific activity as the non-infected control plants when supplied with 10–15 mM nitrate
    corecore