372 research outputs found
A randomised controlled trial to explore attitudes to routine scale and polish and compare manual versus ultrasonic scaling in the general dental service in Scotland [ISRCTN99609795]
BACKGROUND: To investigate, within general dental practice, patients' and vocational dental practitioners' (VDP) attitudes towards the benefits and costs of a simple scale and polish and to compare the experience of using manual versus ultrasonic instruments to scale teeth. METHODS: 28 VDPs and 420 patients participated. Patients were randomly allocated to either group. Patients' and VDPs' attitudes towards, and experience of, the scale and polish were elicited by means of self-administered questionnaires. RESULTS: The majority of patients (99%) believed a scale and polish was beneficial. VDPs considered ultrasonic treatment to be appropriate on significantly more occasions than they did for manual scale and polish (P < 0.001). Patient discomfort: with ultrasonic scaling 69.2% felt 'a little uncomfortable' or worse compared with 60% of those undergoing manual treatment (P = 0.072). VDPs considered treatment charges were appropriate for 77% of patients. CONCLUSION: Routine scaling and polishing is considered beneficial by both patients and vocational trainees. The majority of patients, regardless of treatment method, experience some degree of discomfort when undergoing a scale and polish. VDPs showed a preference for the ultrasonic treatment method
Swab pooling enables rapid expansion of high-throughput capacity for SARS-CoV-2 community testing
Background: The challenges of rapid upscaling of testing capacity were a major lesson from the COVID-19 pandemic response. The need for process adjustments in high-throughput testing laboratories made sample pooling a challenging option to implement. / Objective: This study aimed to evaluate whether pooling samples at source (swab pooling) was as effective as qRT-PCR testing of individuals in identifying cases of SARS-CoV-2 in real-world community testing conditions using the same high-throughput pipeline. / Methods: Two cohorts of 10 (Pool10: 1,030 participants and 103 pools) and 6 (Pool6: 1,284 participants and 214 pools) samples per pool were tested for concordance, sensitivity, specificity, and Ct value differences with individual testing as reference. Results: Swab pooling allowed unmodified application of an existing high-throughput SARS-Cov-2 testing pipeline with only marginal loss of accuracy. For Pool10, concordance was 98.1% (95% Confidence interval: 93.3–99.8%), sensitivity was 95.7% (85.5–99.5%), and specificity was 100.0% (93.6–100.0%). For Pool6, concordance was 97.2% (94.0–99.0%), sensitivity was 97.5% (93.7–99.3%), and specificity was 96.4% (87.7–99.6%). Differences of outcomes measure between pool size were not significant. Most positive individual samples, which were not detected in pools, had very low viral concentration. If only individual samples with a viral concentration > 400 copies/ml (i.e. Ct value < 30) were considered positive, the overall sensitivity of pooling increased to 99.5%. / Conclusion: The study demonstrated high sensitivity and specificity by swab pooling and the immediate capability of high-throughput laboratories to implement this method making it an option in planning of rapid upscaling of laboratory capacity for future pandemics
Self-swabbing versus assisted swabbing for viral detection by qRT-PCR: the experience from SARS-CoV-2 based on a meta-analysis of six prospectively designed evaluations conducted in a UK setting
Purpose: In April 2020, the UK Government implemented NHS Test and Trace to provide SARS-CoV-2 quantitative reverse transcription polymerase chain reaction (qRT-PCR) testing for the public, with nose-and-throat swabbing for samples performed by trained staff. Self-swabbing (SS) would allow rapid scale-up of testing capacity and access. Six studies were undertaken to determine whether SS was as effective for detecting SARS-CoV-2 as swabbing performed by trained staff. Methods: Six prospective studies were conducted between April–October 2020, using six swab/media combinations. Differences between assisted swabbing (AS) and SS were evaluated for concordance, positivity, sensitivity, cycle threshold (Ct) values and void rates. Statistical analysis was performed using 95% confidence intervals (CIs), paired t-tests and model-based methods. Results: Overall, 3,253 individuals were recruited (median age 37 years, 49% female), with 2,933 having valid paired qRT-PCR results. Pooled concordance rate was 98% (95% CI: 96%, 99%). Positivity rate differences for SS (8.1%) and AS (8.4%) and differences in pooled sensitivities between SS (86%; 95% CI: 78%, 92%) and AS (91%; 95% CI: 78%, 96%) were nonsignificant. Both types of swabbing led to pooled void rates below 2% and strongly correlated Ct values. Age, sex and previous swabbing experience did not have a significant impact on concordance or sensitivity. Conclusion: The UK adopted a policy to promote self-testing for SARS-CoV-2 based on data demonstrating equivalence of SS versus AS. Positive outcomes with SS are likely generalisable to testing for other respiratory pathogens, and we consider self-sampling and self-testing essential for future pandemic preparedness
A comparative evaluation of the efficacy of manual, magnetostrictive and piezoelectric ultrasonic instruments: an in vitro profilometric and SEM study
OBJECTIVES: The debridement of diseased root surface is usually performed by mechanical scaling and root planing using manual and power driven instruments. Many new designs in ultrasonic powered scaling tips have been developed. However, their effectiveness as compared to manual curettes has always been debatable. Thus, the objective of this in vitro study was to comparatively evaluate the efficacy of manual, magnetostrictive and piezoelectric ultrasonic instrumentation on periodontally involved extracted teeth using profilometer and scanning electron microscope (SEM). MATERIAL AND METHODS: 30 periodontally involved extracted human teeth were divided into 3 groups. The teeth were instrumented with hand and ultrasonic instruments resembling clinical application. In Group A all teeth were scaled with a new universal hand curette (Hu Friedy Gracey After Five Vision curette; Hu Friedy, Chicago, USA). In Group B Cavitron(TM) FSI - SLI(TM) ultrasonic device with focused spray slimline inserts (Dentsply International Inc., York, PA, USA) were used. In Group C teeth were scaled with an EMS piezoelectric ultrasonic device with prototype modified PS inserts. The surfaces were analyzed by a Precision profilometer to measure the surface roughness (Ra value in µm) consecutively before and after the instrumentation. The samples were examined under SEM at magnifications ranging from 17x to 300x and 600x. RESULTS: The mean Ra values (µm) before and after instrumentation in all the three groups A, B and C were tabulated. After statistically analyzing the data, no significant difference was observed in the three experimental groups. Though there was a decrease in the percentage reduction of Ra values consecutively from group A to C. CONCLUSION: Within the limits of the present study, given that the manual, magnetostrictive and piezoelectric ultrasonic instruments produce the same surface roughness, it can be concluded that their efficacy for creating a biologically compatible surface of periodontally diseased teeth is similar
Anti-glomerular basement membrane disease superimposed on membranous nephropathy: a case report and review of the literature
<p>Abstract</p> <p>Introduction</p> <p>Anti-glomerular basement membrane disease is a rare autoimmune disorder characterized by pulmonary hemorrhage, crescentic glomerulonephritis and the presence of circulating anti-glomerular basement membrane antibodies. The simultaneous occurrence of both anti-glomerular basement membrane disease and membranous nephropathy is rare.</p> <p>Case presentation</p> <p>A 59-year-old Hispanic man presented with acute onset of nausea and vomiting and was found to have renal insufficiency. Work-up included a kidney biopsy, which revealed anti-glomerular basement membrane disease with underlying membranous nephropathy. He was treated with emergent hemodialysis, intravenous corticosteroids, plasmapheresis, and cyclophosphamide without improvement in his renal function.</p> <p>Conclusion</p> <p>Simultaneous anti-glomerular basement membrane disease and membranous nephropathy is very rare. There have been 16 previous case reports in the English language literature that have been associated with a high mortality and morbidity, and a very high rate of renal failure resulting in hemodialysis. Co-existence of membranous nephropathy and anti-glomerular basement membrane disease may be immune-mediated, although the exact mechanism is not clear.</p
Taurolidine-citrate lock solution (TauroLock) significantly reduces CVAD-associated grampositive infections in pediatric cancer patients
<p>Abstract</p> <p>Background</p> <p>Taurolidin/Citrate (TauroLock™), a lock solution with broad spectrum antimicrobial activity, may prevent bloodstream infection (BSI) due to coagulase-negative staphylococci (CoNS or 'MRSE' in case of methicillin-resistant isolates) in pediatric cancer patients with a long term central venous access device (CVAD, Port- or/Broviac-/Hickman-catheter type).</p> <p>Methods</p> <p>In a single center prospective 48-months cohort study we compared all patients receiving anticancer chemotherapy from April 2003 to March 2005 (group 1, heparin lock with 200 IU/ml sterile normal saline 0.9%; Canusal<sup>® </sup>Wockhardt UK Ltd, Wrexham, Wales) and all patients from April 2005 to March 2007 (group 2; taurolidine 1.35%/Sodium Citrate 4%; TauroLock™, Tauropharm, Waldbüttelbrunn, Germany).</p> <p>Results</p> <p>In group 1 (heparin), 90 patients had 98 CVAD in use during the surveillance period. 14 of 30 (47%) BSI were 'primary Gram positive BSI due to CoNS (n = 4) or MRSE (n = 10)' [incidence density (ID); 2.30 per 1000 inpatient CVAD-utilization days].</p> <p>In group 2 (TauroLock™), 89 patients had 95 CVAD in use during the surveillance period. 3 of 25 (12%) BSI were caused by CoNS. (ID, 0.45). The difference in the ID between the two groups was statistically significant (P = 0.004).</p> <p>Conclusion</p> <p>The use of Taurolidin/Citrate (TauroLock™) significantly reduced the number and incidence density of primary catheter-associated BSI due to CoNS and MRSE in pediatric cancer patients.</p
Paediatric Investigators Collaborative Network on Infections in Canada (PICNIC) study of aseptic meningitis
BACKGROUND: The seasonality, clinical and radiographic features and outcome of aseptic meningitis have been described for regional outbreaks but data from a wider geographic area is necessary to delineate the epidemiology of this condition. METHODS: A retrospective chart review was completed of children presenting with aseptic meningitis to eight Canadian pediatric hospitals over a two-year period. RESULTS: There were 233 cases of proven enteroviral (EV) meningitis, 495 cases of clinical aseptic meningitis and 74 cases of possible aseptic meningitis with most cases occurring July to October. Headache, vomiting, meningismus and photophobia were more common in children ≥ 5 years of age, while rash, diarrhea and cough were more common in children < 5 years of age. Pleocytosis was absent in 22.3% of children < 30 days of age with proven EV meningitis. Enterovirus was isolated in cerebrospinal fluid (CSF) from 154 of 389 patients (39.6%) who had viral culture performed, and a nucleic acid amplification test for enterovirus was positive in CSF from 81 of 149 patients (54.3%). Imaging of the head by computerized tomography or magnetic resonance imaging was completed in 96 cases (19.7%) and 24 had abnormal findings that were possibly related to meningitis while none had changes that were definitely related to meningitis. There was minimal morbidity and there were no deaths. CONCLUSION: The clinical presentation of aseptic meningitis varies with the age of the child. Absence of CSF pleocytosis is common in infants < 30 days of age. Enterovirus is the predominant isolate, but no etiologic agent is identified in the majority of cases of aseptic meningitis in Canadian children
IgG-index predicts neurological morbidity in patients with infectious central nervous system diseases
<p>Abstract</p> <p>Background</p> <p>Prognosis assessment of patients with infectious and neoplastic disorders of the central nervous system (CNS) may still pose a challenge. In this retrospective cross-sectional study the prognostic value of basic cerebrospinal fluid (CSF) parameters in patients with bacterial meningitis, viral meningoencephalitis and leptomeningeal metastases were evaluated.</p> <p>Methods</p> <p>White blood cell count, CSF/serum glucose ratio, protein, CSF/serum albumin quotient and Immunoglobulin indices for IgG, IgA and IgM were analyzed in 90 patients with bacterial meningitis, 117 patients with viral meningoencephalitis and 36 patients with leptomeningeal metastases in a total of 480 CSF samples.</p> <p>Results</p> <p>In the initial spinal tap, the IgG-index was the only independent predictor for unfavorable outcome (GOS < 5) in patients with infectious CNS diseases but not in patients with leptomeningeal metastases. The sensitivity and specificity of an IgG-index of 0.75 and higher for predicting unfavorable outcome was 40.9% and 80.8% in bacterial meningitis and 40% and 94.8% in viral meningoencephalitis, respectively. No significant associations between CSF parameters and outcome could be observed in follow-up CSF samples.</p> <p>Conclusion</p> <p>The present study suggests that in infectious CNS diseases an elevated IgG-Index might be an additional marker for the early identification of patients at risk for neurological morbidity.</p
- …