33 research outputs found
ECCCII-Based Current-Mode Universal Filter with Orthogonal Control of w_o and Q
This paper presents a new current-mode current-controlled four-input five-output universal filter employing one current-controlled current conveyor (CCCII), one electronically tunable CCCII and two grounded capacitors. The proposed configuration provides lowpass, bandpass, highpass, bandstop and allpass current responses that taken from the high-output impedance terminals, which enable easy cascadability of the current-mode operation. The filter also offers both orthogonal and electronic controls of the natural frequency and the quality factor through adjusting the bias current of the CCCIIs. For realizing all the filter responses, the proposed filter does not require passive component-matching condition and both active and passive sensitivities are low. In addition, a new current-mode current-controlled single-input five-output universal filter can be achieved by using an additional multiple-output minus-type CCCII. The proposed filter is simulated using PSPICE simulations to confirm the theoretical analysis
Voltage-Mode Multifunction Biquadratic Filters Using New Ultra-Low-Power Differential Difference Current Conveyors
This paper presents two low-power voltage-mode multifunction biquadratic filters using differential difference current conveyors. Each proposed circuit employs three differential difference current conveyors, two grounded capacitors and two grounded resistors. The low-voltage ultra-low-power differential difference current conveyor is used to provide low-power consumption of the proposed filters. By appropriately connecting the input and output terminals, the proposed filters can provide low-pass, band-pass, high-pass, band-stop and all-pass voltage responses at high-input terminals, which is a desirable feature for voltage-mode operations. The natural frequency and the quality factor can be orthogonally set by adjusting the circuit components. For realizing all the filter responses, no inverting-type input signal requirements as well as no component-matching conditional requirements are imposed. The incremental parameter sensitivities are also low. The characteristics of the proposed circuits are simulated by using PSPICE simulators to confirm the presented theory
Flow simulation in coronary artery models: An investigation of the effect of variable angulations at left coronary artery
This study was designed to investigate the hemodynamics in the left coronary artery with the aim of identifying the relationship between angulations of left coronary bifurcation and development of atherosclerosis. Six 3D left coronary models were simulated for computational fluid dynamic analysis. The left coronary model was composed of left main stem, left anterior descending and left circumflex branches. The angulations at the left bifurcation weresimulated with angles ranging from 90°, 75°, 60°, 45°, 30° to 15°. The computational fluid dynamic was used for analysis of flow velocity, wall pressure and wall shear stress. Our results showed that apparent low shear stress and high wall pressure was noticed at the left coronary bifurcation regions with wide angled models. Flow pattern was also changed with angled becoming wide in the simulated models. Our analysis shows direction relationship between coronary angulation and development of atherosclerosis. Future studies are required to perform computational fluid dynamic analysis in coronary models from patients' data with different degree of coronary stenosis
Automatic control of finite element models for temperature-controlled radiofrequency ablation
BACKGROUND: The finite element method (FEM) has been used to simulate cardiac and hepatic radiofrequency (RF) ablation. The FEM allows modeling of complex geometries that cannot be solved by analytical methods or finite difference models. In both hepatic and cardiac RF ablation a common control mode is temperature-controlled mode. Commercial FEM packages don't support automating temperature control. Most researchers manually control the applied power by trial and error to keep the tip temperature of the electrodes constant. METHODS: We implemented a PI controller in a control program written in C++. The program checks the tip temperature after each step and controls the applied voltage to keep temperature constant. We created a closed loop system consisting of a FEM model and the software controlling the applied voltage. The control parameters for the controller were optimized using a closed loop system simulation. RESULTS: We present results of a temperature controlled 3-D FEM model of a RITA model 30 electrode. The control software effectively controlled applied voltage in the FEM model to obtain, and keep electrodes at target temperature of 100°C. The closed loop system simulation output closely correlated with the FEM model, and allowed us to optimize control parameters. DISCUSSION: The closed loop control of the FEM model allowed us to implement temperature controlled RF ablation with minimal user input
Could it be advantageous to tune the temperature controller during radiofrequency ablation? A feasibility study using theoretical models
Purpose: To assess whether tailoring the Kp and Ki values of a proportional-integral (PI) controller during radiofrequency (RF) cardiac ablation could be advantageous from the point of view of the dynamic behaviour of the controller, in particular, whether control action could be speeded up and larger lesions obtained.
Methods: Theoretical models were built and solved by the finite element method. RF cardiac ablations were simulated with temperature controlled at 55 degrees C. Specific PI controllers were implemented with Kp and Ki parameters adapted to cases with different tissue values (specific heat, thermal conductivity and electrical conductivity) electrode-tissue contact characteristics (insertion depth, cooling effect of circulating blood) and electrode characteristics (size, location and arrangement of the temperature sensor in the electrode).
Results: The lesion dimensions and T(max) remained almost unchanged when the specific PI controller was used instead of one tuned for the standard case: T(max) varied less than 1.9 degrees C, lesion width less than 0.2 mm, and lesion depth less than 0.3 mm. As expected, we did observe a direct logical relationship between the response time of each controller and the transient value of electrode temperature.
Conclusion: The results suggest that a PI controller designed for a standard case (such as that described in this study), could offer benefits under different tissue conditions, electrode-tissue contact, and electrode characteristics.This work received financial support from the Spanish 'Plan Nacional de I+D+I del Ministerio de Ciencia e Innovacion' Grant no. TEC2008-01369/TEC and FEDER Project MTM2010-14909. The translation of this paper was funded by the Universitat Politecnica de Valencia, Spain. The authors alone are responsible for the content and writing of the paperAlba Martínez, J.; Trujillo Guillen, M.; Blasco Giménez, RM.; Berjano Zanón, E. (2011). Could it be advantageous to tune the temperature controller during radiofrequency ablation? A feasibility study using theoretical models. International Journal of Hyperthermia. 27(6):539-548. https://doi.org/10.3109/02656736.2011.586665S539548276Gaita, F., Caponi, D., Pianelli, M., Scaglione, M., Toso, E., Cesarani, F., … Leclercq, J. F. (2010). Radiofrequency Catheter Ablation of Atrial Fibrillation: A Cause of Silent Thromboembolism? Circulation, 122(17), 1667-1673. doi:10.1161/circulationaha.110.937953Anfinsen, O.-G., Aass, H., Kongsgaard, E., Foerster, A., Scott, H., & Amlie, J. P. (1999). Journal of Interventional Cardiac Electrophysiology, 3(4), 343-351. doi:10.1023/a:1009840004782PETERSEN, H. H., CHEN, X., PIETERSEN, A., SVENDSEN, J. H., & HAUNSO, S. (2000). Tissue Temperatures and Lesion Size During Irrigated Tip Catheter Radiofrequency Ablation: An In Vitro Comparison of Temperature-Controlled Irrigated Tip Ablation, Power-Controlled Irrigated Tip Ablation, and Standard Temperature-Controlled Ablation. Pacing and Clinical Electrophysiology, 23(1), 8-17. doi:10.1111/j.1540-8159.2000.tb00644.xTungjitkusolmun, S., Woo, E. J., Cao, H., Tsai, J. Z., Vorperian, V. R., & Webster, J. G. (2000). Thermal—electrical finite element modelling for radio frequency cardiac ablation: Effects of changes in myocardial properties. Medical & Biological Engineering & Computing, 38(5), 562-568. doi:10.1007/bf02345754Lai, Y.-C., Choy, Y. B., Haemmerich, D., Vorperian, V. R., & Webster, J. G. (2004). Lesion Size Estimator of Cardiac Radiofrequency Ablation at Different Common Locations With Different Tip Temperatures. IEEE Transactions on Biomedical Engineering, 51(10), 1859-1864. doi:10.1109/tbme.2004.831529Jain, M. K., & Wolf, P. D. (1999). Temperature-controlled and constant-power radio-frequency ablation: what affects lesion growth? IEEE Transactions on Biomedical Engineering, 46(12), 1405-1412. doi:10.1109/10.804568Panescu, D., Whayne, J. G., Fleischman, S. D., Mirotznik, M. S., Swanson, D. K., & Webster, J. G. (1995). Three-dimensional finite element analysis of current density and temperature distributions during radio-frequency ablation. IEEE Transactions on Biomedical Engineering, 42(9), 879-890. doi:10.1109/10.412649Hong Cao, Vorperian, V. R., Tungjitkusolmun, S., Jan-Zern Tsai, Haemmerich, D., Young Bin Choy, & Webster, J. G. (2001). Flow effect on lesion formation in RF cardiac catheter ablation. IEEE Transactions on Biomedical Engineering, 48(4), 425-433. doi:10.1109/10.915708Tungjitkusolmun, S., Vorperian, V. R., Bhavaraju, N., Cao, H., Tsai, J.-Z., & Webster, J. G. (2001). Guidelines for predicting lesion size at common endocardial locations during radio-frequency ablation. IEEE Transactions on Biomedical Engineering, 48(2), 194-201. doi:10.1109/10.909640Schutt, D., Berjano, E. J., & Haemmerich, D. (2009). Effect of electrode thermal conductivity in cardiac radiofrequency catheter ablation: A computational modeling study. International Journal of Hyperthermia, 25(2), 99-107. doi:10.1080/02656730802563051Langberg, J. J., Calkins, H., el-Atassi, R., Borganelli, M., Leon, A., Kalbfleisch, S. J., & Morady, F. (1992). Temperature monitoring during radiofrequency catheter ablation of accessory pathways. Circulation, 86(5), 1469-1474. doi:10.1161/01.cir.86.5.1469Calkins, H., Prystowsky, E., Carlson, M., Klein, L. S., Saul, J. P., & Gillette, P. (1994). Temperature monitoring during radiofrequency catheter ablation procedures using closed loop control. Atakr Multicenter Investigators Group. Circulation, 90(3), 1279-1286. doi:10.1161/01.cir.90.3.1279Lennox CD, Temperature controlled RF coagulation. Patent number: 5.122.137 Hudson NHEdwards SD, Stern RA, Electrode and associated system using thermally insulated temperature sensing elements. Patent number: US Patent 5,456,682Panescu D, Fleischman SD, Whayne JG, Swanson DK, (EP Technology. Effects of temperature sensor placement on performance of temperature-controlled ablation. IEEE 17th Annual Conference, Engineering in Medicine and Biology Society, Montreal, Canada (1995)BLOUIN, L. T., MARCUS, F. I., & LAMPE, L. (1991). Assessment of Effects of a Radiofrequency Energy Field and Thermistor Location in an Electrode Catheter on the Accuracy of Temperature Measurement. Pacing and Clinical Electrophysiology, 14(5), 807-813. doi:10.1111/j.1540-8159.1991.tb04111.xBerjano, E. J. (2006). BioMedical Engineering OnLine, 5(1), 24. doi:10.1186/1475-925x-5-24Bhavaraju, N. C., Cao, H., Yuan, D. Y., Valvano, J. W., & Webster, J. G. (2001). Measurement of directional thermal properties of biomaterials. IEEE Transactions on Biomedical Engineering, 48(2), 261-267. doi:10.1109/10.909647Hong Cao, Tungjitkusolmun, S., Young Bin Choy, Jang-Zern Tsai, Vorperian, V. R., & Webster, J. G. (2002). Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation. IEEE Transactions on Biomedical Engineering, 49(3), 247-253. doi:10.1109/10.983459PETERSEN, H. H., & SVENDSEN, J. H. (2003). Can Lesion Size During Radiofrequency Ablation Be Predicted By the Temperature Rise to a Low Power Test Pulse in Vitro? Pacing and Clinical Electrophysiology, 26(8), 1653-1659. doi:10.1046/j.1460-9592.2003.t01-1-00248.xLANGBERG, J. J., LEE, M. A., CHIN, M. C., & ROSENQVIST, M. (1990). Radiofrequency Catheter Ablation: The Effect of Electrode Size on Lesion Volume In Vivo. Pacing and Clinical Electrophysiology, 13(10), 1242-1248. doi:10.1111/j.1540-8159.1990.tb02022.
In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
BACKGROUND: We need a sensor to measure the convective heat transfer coefficient during ablation of the heart or liver. METHODS: We built a minimally invasive instrument to measure the in vivo convective heat transfer coefficient, h in animals, using a Wheatstone-bridge circuit, similar to a hot-wire anemometer circuit. One arm is connected to a steerable catheter sensor whose tip is a 1.9 mm × 3.2 mm thin film resistive temperature detector (RTD) sensor. We used a circulation system to simulate different flow rates at 39°C for in vitro experiments using distilled water, tap water and saline. We heated the sensor approximately 5°C above the fluid temperature. We measured the power consumed by the sensor and the resistance of the sensor during the experiments and analyzed these data to determine the value of the convective heat transfer coefficient at various flow rates. RESULTS: From 0 to 5 L/min, experimental values of h in W/(m(2)·K) were for distilled water 5100 to 13000, for tap water 5500 to 12300, and for saline 5400 to 13600. Theoretical values were 1900 to 10700. CONCLUSION: We believe this system is the smallest, most accurate method of minimally invasive measurement of in vivo h in animals and provides the least disturbance of flow
Finite Element Analysis of Hepatic Radiofrequency Ablation Probes using Temperature-Dependent Electrical Conductivity
BACKGROUND: Few finite element models (FEM) have been developed to describe the electric field, specific absorption rate (SAR), and the temperature distribution surrounding hepatic radiofrequency ablation probes. To date, a coupled finite element model that accounts for the temperature-dependent electrical conductivity changes has not been developed for ablation type devices. While it is widely acknowledged that accounting for temperature dependent phenomena may affect the outcome of these models, the effect has not been assessed. METHODS: The results of four finite element models are compared: constant electrical conductivity without tissue perfusion, temperature-dependent conductivity without tissue perfusion, constant electrical conductivity with tissue perfusion, and temperature-dependent conductivity with tissue perfusion. RESULTS: The data demonstrate that significant errors are generated when constant electrical conductivity is assumed in coupled electrical-heat transfer problems that operate at high temperatures. These errors appear to be closely related to the temperature at which the ablation device operates and not to the amount of power applied by the device or the state of tissue perfusion. CONCLUSION: Accounting for temperature-dependent phenomena may be critically important in the safe operation of radiofrequency ablation device that operate near 100°C
Thermal modeling of lesion growth with radiofrequency ablation devices
BACKGROUND: Temperature is a frequently used parameter to describe the predicted size of lesions computed by computational models. In many cases, however, temperature correlates poorly with lesion size. Although many studies have been conducted to characterize the relationship between time-temperature exposure of tissue heating to cell damage, to date these relationships have not been employed in a finite element model. METHODS: We present an axisymmetric two-dimensional finite element model that calculates cell damage in tissues and compare lesion sizes using common tissue damage and iso-temperature contour definitions. The model accounts for both temperature-dependent changes in the electrical conductivity of tissue as well as tissue damage-dependent changes in local tissue perfusion. The data is validated using excised porcine liver tissues. RESULTS: The data demonstrate the size of thermal lesions is grossly overestimated when calculated using traditional temperature isocontours of 42°C and 47°C. The computational model results predicted lesion dimensions that were within 5% of the experimental measurements. CONCLUSION: When modeling radiofrequency ablation problems, temperature isotherms may not be representative of actual tissue damage patterns
Ring electrode for radio-frequency heating of the cornea: modelling and in vitro experiments
[EN] Radio-frequency thermokeratoplasty (RF-TKP) is a technique used to reshape the cornea curvature by means of thermal lesions using radio-frequency currents. This curvature change allows refractive disorders such as hyperopia to be corrected. A new electrode with ring geometry is proposed for RF-TKP. It was designed to create a single thermal lesion with a full-circle shape. Finite element models were developed, and the temperature distributions in the cornea were analysed for different ring electrode characteristics. The computer results indicated that the maximum temperature in the cornea was located in the vicinity of the ring electrode outer perimeter, and that the lesions had a semi-torus shape. The results also indicated that the electrode thickness, electrode radius and electrode thermal conductivity had a significant influence on the temperature distributions. In addition, in vitro experiments were performed on rabbit eyes. At 5 IN power the lesions were fully circular. Some lesions showed non-uniform characteristics along their circular path. Lesion depth depended on heating duration (60% of corneal thickness for 20s, and 30% for 10s). The results suggest that the critical shrinkage temperature (55-63degreesC) was reached at the central stroma and along the entire circular path in all the cases.Berjano, E.; Saiz Rodríguez, FJ.; Alió, J.; Ferrero, JM. (2003). Ring electrode for radio-frequency heating of the cornea: modelling and in vitro experiments. Medical & Biological Engineering & Computing. 41(6):630-639. https://doi.org/10.1007/BF02349970S630639416Alió, J. L., Ismail, M. M., Artola, A., andPérez-Santonja, J. J. (1997a): ‘Correction of hyperopia induced by photorefractive keratectomy using non-contact Ho: YAG laser thermal keratoplasty’,J. Refract. Surg.,13, pp. 13–16Alió, J. L., Ismail, M. M., andSanchez, J. L. (1997b): ‘Correction of hyperopia with non-contact Ho: YAG laser thermal keratoplasty’,J. Refract. Surg.,13, pp. 17–22Alió, J. L., andPérez-Santonja, J. J. (1999): ‘Correction of hyperopia by laser thermokeratoplasty (LTK)’ inPallikaris, I., andAgarwal, S. (Eds): ‘Refractive Surgery’ (Jaypee Brothers Medical Publishers Ltd, New Delhi, 1999), pp. 583–591Alió, J. L., andPérez-Santonja, J. J. (2002): ‘Correction of hyperopia by laser thermokeratoplasty (LTK)’ inAgarwal, S., Agarwal, A., Apple, D. J., Buratto, L., Alió, J. L., Pandey, S. K., andAgarwal, A. (Eds): ‘Textbook of ophthalmology’ (Lippincott Williams & Wilkins, Philadelphia, 2002), pp. 1331–1337Ayala, M. J., Alió, J. L., Ismail, M. M., andSánchez-Castro, J. M. (2000): ‘Experimental corneal histological study after thermokeratoplasty with holmium laser’,Arch. Soc. Esp. Oftalmol.,75, pp. 619–626Asbell, P. A., Maloney, R. K., Davidorf, J., Hersh, P., McDonald, M., Manche, E., andConductive Keratoplasty Study Group (2001): ‘Conductive keratoplasty for the correction of hyperopia’,Tr. Am. Ophtalmol. Soc.,99, pp. 79–87Avitall, B., Mughal, K., Hare, J., Helms, R., andKrum, D. (1997): ‘The effects of electrode-tissue contact on radiofrequency lesion generation’PACE,20, pp. 2899–2910Avitall, B., Helms, R. W., Koblish, J. B., Sieben, W., Kotov, A. V., andGupta, G. N. (1999): ‘The creation of linear contiguous lesions in the atria with an expandable loop catheter’,J. Am. Coll. Cardiol.,33, pp. 972–984Berjano, E. J., Saiz, J., andFerrero, J. M. (2002): ‘Radio-frequency heating of the cornea: Theoretical model andin vitro experiments’,IEEE Trans. Biomed. Eng.,49, pp. 196–205Brickmann, R., Kampmeier, J., Grotehusmann, U., Vogel, A., Koop, N., Asiyo-Vogel, M., Kamm, K., andBirngruber, R. (1996): ‘Corneal collagen denaturation in laserthermokeratoplasty’,SPIE Proc.,2681, pp. 56–63Choi, B., Kim, J., Welch, A. J., andPearce, J. A. (2002): ‘Dynamic impedance measurements during radio-frequency heating of cornea’,IEEE Trans. Biomed. Eng.,49, pp. 1610–1616Curley, M. G., andHamilton, P. S. (1997): ‘Creation of large thermal lesions in liver using saline-enhanced RF ablation’. Proc. 19th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc., Chicago, pp. 2516–2519Doss, J. D., andAlbillar, J. I. (1980): ‘A technique for the selective heating of corneal stroma’,Contact Intraocular Lens Med.,6, pp. 13–17Doss, J. D. (1982): ‘Calculation of electric fields in conductive media’,Med. Phys.,9(4), pp. 566–573Gruenberg, P., Manning, W., Miller, D. andOlson, W. (1981): ‘Increase in rabbit corneal curvature by heated ring application’,Ann. Ophthalmol.,13, pp. 67–70Hata, C., andRaymond Chia, W.-K. (2001): ‘Catheter for circular tissue ablation and methods thereof’. US Patent 2001/0044625 A1Jain, M. K., andWolf, P. D. (1998): ‘Effect of electrode contact on lesion growth during temperature controlled radiofrequency ablation’, Proc. 20th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. Hong Kong (IEEE, Piscataway NJ) pp. 245–247Jain, M. K., andWolf, P. D. (1999): ‘Temperature controlled and constant power radiofrequency ablation: what affects lesion growth?’,IEEE Trans. Biomed. Eng.,46, pp. 1405–1412Krasteva, V. Tz., andPapazov, S. P. (2002): ‘Estimation of current density distribution under electrodes for external defibrillation’,Biomed. Eng. OnLine,1, 7Labonté, S. (1992): ‘A theoretical study of radio-frequency ablation of the myocardium’,PhD dissertation, Department of Electrical Engineering, University of Ottawa, CanadaLabonté, S. (1994): ‘Numerical model for radio-frequency ablation of the endocardium and its experimental validation’,IEEE Trans. Biomed. Eng.,41, pp. 108–115Mannis, M. J., Segal, W. A., andDarlington, J. K. (2001): ‘Making sense of refractive surgery in 2001: Why, when, for whom, and by whom?’,Mayo Clin. Proc.,76, pp. 823–829McCally, R. L., Bargeron, R. A., andGreen, W. R. (1983): ‘Stromal damage in rabbit corneas exposed to CO2 laser radiation’,Exp. Eye Res.,37, pp. 543–550McDonald, M. B., Hersh, P. S., Manche, E. E., Maloney, R. K., Davidorf, J., andSabry, M. (2002): ‘Conductive keratoplasty for the correction of low to moderate hyperopia: U.S. clinical trial 1-year results on 355 eyes’,Ophthalmol.,109, pp. 1978–1989McRury, I. D., Mitchell, M. A., Panescu, D. andHaines, D. E. (1997): ‘Non-uniform heating during radiofrequency ablation with long electrodes: monitoring the edge effect’,Circ.,96, pp. 4057–4064Méndez-g, A., andMéndez-Noble, A. (1997): ‘Conductive keratoplasty of the correction of hyperopia’ inSher, N. A. (Ed.) ‘Surgery for hyperopia and presbyopia’ (Williams & Wilkins, Baltimore, 1997), pp. 163–171Miller, D., andManning, W.J. (1978): ‘Alterations in curvature of bovine cornea using heated rings’,Invest. Ophthalmol., p. 297Mirotznik, M. S., andSchwartzman, D. (1996): ‘Nonuniform heating patterns of commercial electrodes for radiofrequency catheter ablation’,J. Cardiovasc. Electrophysiol.,7, pp. 1058–1062Nakagawa, H., Yamanashi, W. S., Pitha, J. V., Arruda, M., Wang, X., Ohtomo, K., Beckman, K. J., McClelland, J. H., Lazzara, R., andJackman, W. M. (1995): ‘Comparison ofin vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation’,Circ.,91, pp. 2264–2273Panescu, D., Whayne, J. G., Fleischman, S. D., Mirotznik, M. S., Swanson, D. K., andWebster, J. G. (1995): ‘Three-dimensional finite element analysis of current density and temperature distributions during radio-frequency ablation’,IEEE Trans. Biomed. Eng.,42, pp. 879–890Plonsey, R., andHeppner, D. B. (1967): ‘Considerations of quasistationarity in electrophysiological systems’,Bull. Math. Biophys.,29, pp. 657–664Rowsey, J. J. (1987): ‘Electrosurgical keratoplasty: Update and retraction’,Invest. Ophthalmol. Vis. Sci.,28, p. 224Rutzen, A. R., Roberts, C. W., Driller, J., Gomez, D., Lucas, B. C., Lizzi, F. L., andColeman, D. J. (1990): ‘Production of corneal lesions using high-intensity focused ultrasound’,Cornea,9, pp. 324–330Schwan, H. P., andFoster, K. R. (1980): ‘RF-fields interactions with biological systems: electrical properties and biophysical mechanism’,Proc. IEEE,68, pp. 104–113Seiler, T., Matallana, M., andBende, T. (1990): ‘Laser thermokeratoplasty by means of a pulsed Holmium:YAG Laser for the hyperopic correction’,Refrac. Corneal Surg.,6, pp. 335–339Silvestrini, T. A. (1998): ‘Electrosurgical procedure for the treatment of the cornea’. US Patent 5,766,171Simmons, W. N., Mackey, S., He, D. S. andMarcus, F. L. (1996): ‘Comparison of gold versus platinum electrodes on myocardial lesion size using radiofrequency energy’,PACE,19, pp. 398–402Stringer, H., andParr, J. (1964): ‘Shrinkage temperature of eye collagen’,Nature,204, p. 1307Trembly, B. S., andKeates, R. H. (1991): ‘Combined microwave heating and surface cooling of the cornea’,IEEE Trans. Biomed. Eng.,38, pp. 85–91Trembly, B. S., Hashizume, N., Moodie, K. L., Cohen, K. L., Tripoli, N. K., andHoopes, P. J. (2001): ‘Microwave thermal keratoplasty for myopia: keratoscopic evaluation in porcine eyes’,J. Refract. Surg.,17, pp. 682–688Tungjitkusolmun, S., Woo, E. J., Cao, H., Tsai, J. Z., Vorperian, V. R., andWebster, J. G. (2000): ‘Thermal-electrical finite element modelling for radio frequency cardiac ablation: effects of changes in myocardial properties’,Med. Biol. Eng. Comput.,38, pp. 562–568Wiley, J. D., andWebster, J. G. (1982): ‘Analysis and control of the current distribution under circular dispersive electrodes’,IEEE Trans. Biomed. Eng,29, pp. 381–38
Feasibility study of an internally cooled bipolar applicator for RF coagulation of hepatic tissue: Experimental and computational study
Purpose: To study the capacity of an internally cooled radiofrequency (RF) bipolar applicator to create sufficiently deep thermal lesions in hepatic tissue. Materials and methods: Three complementary methodologies were employed to check the electrical and thermal behaviour of the applicator under test. The experimental studies were based on excised bovine (ex vivo study) and porcine liver (in vivo study) and the theoretical models were solved by means of the finite element method (FEM). Results: Experimental and computational results showed good agreement in terms of impedance progress and lesion depth (4 and 4.5 mm respectively for ex vivo conditions, and approximately 7 and 9 mm respectively for in vivo conditions), although the lesion widths were overestimated by the computer simulations. This could have been due to the method used to assess the thermal lesions; the experimental lesions were assessed by the white coagulation zone, whereas the tissue damage function was used to assess the computational lesions. Conclusions: The experimental results suggest that this applicator could create in vivo lesions to a depth of around 7mm. It was also observed that the thermal lesion is mainly confined to the area between both electrodes, which would allow lesion width to be controlled by selecting a specific applicator design. The comparison between the experimental and computational results suggests that the theoretical model could be usefully applied in further studies of the performance of this device. © 2012 Informa UK Ltd All rights reserved.This work received financial support from the Spanish Plan Nacional de I+D+I del Ministerio de Ciencia e Innovacion TEC2011-27133-C02-(01 and 02), from Universitat Politecnica de Valencia (INNOVA11-01-5502; and PAID-06-11 Ref. 1988). A. Gonzalez-Suarez is the recipient of grant VaLi+D (ACIF/2011/194) from the Generalitat Valenciana. The proof-reading of this paper was funded by the Universitat Politecnica de Valencia, Spain. The authors alone are responsible for the content and writing of the paper.González Suárez, A.; Trujillo Guillen, M.; Burdío Pinilla, F.; Andaluz Martínez, AM.; Berjano Zanón, E. (2012). Feasibility study of an internally cooled bipolar applicator for RF coagulation of hepatic tissue: Experimental and computational study. International Journal of Hyperthermia. 28(7):663-673. https://doi.org/10.3109/02656736.2012.716900S663673287Topp, S. A., McClurken, M., Lipson, D., Upadhya, G. A., Ritter, J. H., Linehan, D., & Strasberg, S. M. (2004). Saline-Linked Surface Radiofrequency Ablation. Annals of Surgery, 239(4), 518-527. doi:10.1097/01.sla.0000118927.83650.a4Gnerlich, J. L., Ritter, J. H., Linehan, D. C., Hawkins, W. G., & Strasberg, S. M. (2009). Saline-Linked Surface Radiofrequency Ablation. Annals of Surgery, 250(1), 96-102. doi:10.1097/sla.0b013e3181ae91afSakamoto, Y., Yamamoto, J., Kokudo, N., Seki, M., Kosuge, T., Yamaguchi, T., … Makuuchi, M. (2004). Bloodless liver resection using the Monopolar Floating Ball plus Ligasure diathermy: Preliminary results of 16 liver resections. World Journal of Surgery, 28(2), 166-172. doi:10.1007/s00268-003-7167-5Poon, R. T., Fan, S. T., & Wong, J. (2005). Liver resection using a saline-linked radiofrequency dissecting sealer for transection of the liver. Journal of the American College of Surgeons, 200(2), 308-313. doi:10.1016/j.jamcollsurg.2004.10.008EVERETT IV, T. H., LEE, K. W., WILSON, E. E., GUERRA, J. M., VAROSY, P. D., & OLGIN, J. E. (2008). Safety Profiles and Lesion Size of Different Radiofrequency Ablation Technologies: A Comparison of Large Tip, Open and Closed Irrigation Catheters. Journal of Cardiovascular Electrophysiology, 20(3), 325-335. doi:10.1111/j.1540-8167.2008.01305.xYokoyama, K., Nakagawa, H., Wittkampf, F. H. M., Pitha, J. V., Lazzara, R., & Jackman, W. M. (2006). Comparison of Electrode Cooling Between Internal and Open Irrigation in Radiofrequency Ablation Lesion Depth and Incidence of Thrombus and Steam Pop. Circulation, 113(1), 11-19. doi:10.1161/circulationaha.105.540062Demazumder, D., Mirotznik, M. S., & Schwartzman, D. (2001). Journal of Interventional Cardiac Electrophysiology, 5(4), 391-400. doi:10.1023/a:1013241927388Cooper, J. M., Sapp, J. L., Tedrow, U., Pellegrini, C. P., Robinson, D., Epstein, L. M., & Stevenson, W. G. (2004). Ablation with an internally irrigated radiofrequency catheter: Learning how to avoid steam pops. Heart Rhythm, 1(3), 329-333. doi:10.1016/j.hrthm.2004.04.019Burdío, F., Grande, L., Berjano, E., Martinez-Serrano, M., Poves, I., Burdío, J. M., … Güemes, A. (2010). A new single-instrument technique for parenchyma division and hemostasis in liver resection: a clinical feasibility study. The American Journal of Surgery, 200(6), e75-e80. doi:10.1016/j.amjsurg.2010.02.020Ríos, J. S., Zalabardo, J. M. S., Burdio, F., Berjano, E., Moros, M., Gonzalez, A., … Güemes, A. (2011). Single Instrument for Hemostatic Control in Laparoscopic Partial Nephrectomy in a Porcine Model Without Renal Vascular Clamping. Journal of Endourology, 25(6), 1005-1011. doi:10.1089/end.2010.0557Dorcaratto, D., Burdío, F., Fondevila, D., Andaluz, A., Poves, I., Martinez, M. A., … Grande, L. (2012). Laparoscopic Distal Pancreatectomy: Feasibility Study of Radiofrequency-Assisted Transection in a Porcine Model. Journal of Laparoendoscopic & Advanced Surgical Techniques, 22(3), 242-248. doi:10.1089/lap.2011.0417Zeh, A., Messer, J., Davis, J., Vasarhelyi, A., & Wohlrab, D. (2010). The Aquamantys System—An Alternative To Reduce Blood Loss in Primary Total Hip Arthroplasty? The Journal of Arthroplasty, 25(7), 1072-1077. doi:10.1016/j.arth.2009.10.008Sprunger, J., & Herrell, S. D. (2005). Partial Laparoscopic Nephrectomy Using Monopolar Saline-Coupled Radiofrequency Device: Animal Model and Tissue Effect Characterization. Journal of Endourology, 19(4), 513-519. doi:10.1089/end.2005.19.513Voeller, R. K., Zierer, A., Lall, S. C., Sakamoto, S., Schuessler, R. B., & Damiano, R. J. (2010). Efficacy of a novel bipolar radiofrequency ablation device on the beating heart for atrial fibrillation ablation: A long-term porcine study. The Journal of Thoracic and Cardiovascular Surgery, 140(1), 203-208. doi:10.1016/j.jtcvs.2009.06.034Pai, M., Spalding, D., Jiao, L., & Habib, N. (2012). Use of Bipolar Radiofrequency in Parenchymal Transection of the Liver, Pancreas and Kidney. Digestive Surgery, 29(1), 43-47. doi:10.1159/000335732Berjano, E. J. (2006). BioMedical Engineering OnLine, 5(1), 24. doi:10.1186/1475-925x-5-24Tungjitkusolmun, S., Staelin, S. T., Haemmerich, D., Jang-Zern Tsai, Hong Cao, Webster, J. G., … Vorperian, V. R. (2002). Three-dimensional finite-element analyses for radio-frequency hepatic tumor ablation. IEEE Transactions on Biomedical Engineering, 49(1), 3-9. doi:10.1109/10.972834Doss, J. D. (1982). Calculation of electric fields in conductive media. Medical Physics, 9(4), 566-573. doi:10.1118/1.595107Abraham, J. P., & Sparrow, E. M. (2007). A thermal-ablation bioheat model including liquid-to-vapor phase change, pressure- and necrosis-dependent perfusion, and moisture-dependent properties. International Journal of Heat and Mass Transfer, 50(13-14), 2537-2544. doi:10.1016/j.ijheatmasstransfer.2006.11.045Jo, B., & Aksan, A. (2010). Prediction of the extent of thermal damage in the cornea during conductive keratoplasty. Journal of Thermal Biology, 35(4), 167-174. doi:10.1016/j.jtherbio.2010.02.004Pearce, J., Panescu, D., & Thomsen, S. (2005). Simulation of diopter changes in radio frequency conductive keratoplasty in the cornea. Modelling in Medicine and Biology VI. doi:10.2495/bio050451Yang, D., Converse, M. C., Mahvi, D. M., & Webster, J. G. (2007). Expanding the Bioheat Equation to Include Tissue Internal Water Evaporation During Heating. IEEE Transactions on Biomedical Engineering, 54(8), 1382-1388. doi:10.1109/tbme.2007.890740Zhao, G., Zhang, H.-F., Guo, X.-J., Luo, D.-W., & Gao, D.-Y. (2007). Effect of blood flow and metabolism on multidimensional heat transfer during cryosurgery. Medical Engineering & Physics, 29(2), 205-215. doi:10.1016/j.medengphy.2006.03.005Pätz T, Körger T, Preusser T, Simulation of radiofrequency ablation including water evaporation. In: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering 25/IV, 2009, 1287–1290Berjano, E. J., Burdío, F., Navarro, A. C., Burdío, J. M., Güemes, A., Aldana, O., … Gregorio, M. A. de. (2006). Improved perfusion system for bipolar radiofrequency ablation of liver: preliminary findings from a computer modeling study. Physiological Measurement, 27(10), N55-N66. doi:10.1088/0967-3334/27/10/n03Burdío, F., Berjano, E. J., Navarro, A., Burdío, J. M., Grande, L., Gonzalez, A., … Lequerica, J. L. (2009). Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments. BioMedical Engineering OnLine, 8(1), 6. doi:10.1186/1475-925x-8-6Chang, I. A., & Nguyen, U. D. (2004). BioMedical Engineering OnLine, 3(1), 27. doi:10.1186/1475-925x-3-27Beop-Min Kim, Jacques, S. L., Rastegar, S., Thomsen, S., & Motamedi, M. (1996). Nonlinear finite-element analysis of the role of dynamic changes in blood perfusion and optical properties in laser coagulation of tissue. IEEE Journal of Selected Topics in Quantum Electronics, 2(4), 922-933. doi:10.1109/2944.577317Panescu, D., Whayne, J. G., Fleischman, S. D., Mirotznik, M. S., Swanson, D. K., & Webster, J. G. (1995). Three-dimensional finite element analysis of current density and temperature distributions during radio-frequency ablation. IEEE Transactions on Biomedical Engineering, 42(9), 879-890. doi:10.1109/10.412649González-Suárez A, Alba J, Trujillo M, Berjano E, Experimental and theoretical study of an internally cooled bipolar electrode for RF coagulation of biological tissues. Conf Proc IEEE Eng Med Biol Soc 2011;6878–6881Rosenberg, A. G. (2007). Reducing Blood Loss in Total Joint Surgery With a Saline-Coupled Bipolar Sealing Technology. The Journal of Arthroplasty, 22(4), 82-85. doi:10.1016/j.arth.2007.02.018PETERSEN, H. H., ROMAN-GONZALEZ, J., JOHNSON, S. B., HASTRUP SVENDSEN, J., HAUNSO, S., & PACKER, D. L. (2004). Mechanisms for Enlarging Lesion Size During Irrigated Tip Radiofrequency Ablation:. Is There a Virtual Electrode Effect? Journal of Interventional Cardiology, 17(3), 171-177. doi:10.1111/j.1540-8183.2004.09879.