265 research outputs found

    Comparisons of global topographic/isostatic models to the Earth's observed gravity field

    Get PDF
    The Earth's gravitational potential, as described by a spherical harmonic expansion to degree 180, was compared to the potential implied by the topography and its isostatic compensation using five different hypothesis. Initially, series expressions for the Airy/Heiskanen topographic isostatic model were developed to the third order in terms of (h/R), where h is equivalent rock topography and R is a mean Earth radius. Using actual topographic developments for the Earth, it was found that the second and third terms of the expansion contributed 30 and 3 percents, of the first of the expansion. With these new equations it is possible to compute depths (D) of compensation, by degree, using 3 different criteria. The results show that the average depth implied by criterion I is 60 km while it is about 33 km for criteria 2 and 3 with smaller compensation depths at the higher degrees. Another model examined was related to the Vening-Meinesz regional hypothesis implemented in the spectral domain. Finally, oceanic and continental response functions were derived for the global data sets and comparisons made to locally determined values

    Covariance expressions for second and lower order derivatives of the anomalous potential

    Get PDF
    The University Archives has determined that this item is of continuing value to OSU's history.Auto- and cross-covariance expressions for the anomalous potential of the Earth and its first and second order derivatives are derived based on three different degree-variance models. A Fortran IV subroutine is listed and documented that may be used for the computation of auto- and cross-covariance between any of the following quantities: (1) the anomalous potential (T), (2) the negative gravity disturbance/r, (3) the gravity anomaly Δg, (5) the second order radial derivative of T, (6), (7) the latitude and longitude components of the deflection of the vertical, (8), (9) the derivatives of northern and eastern direction of Δg, (10), (11) the derivatives of the gravity disturbance in northern and eastern direction, (12) – (14) the second order derivatives of T in northern, in mixed northern and eastern and in eastern direction. Values of different kinds of covariance of second order derivatives for varying spherical distance and height are tabulated.Danish Geodetic InstituteU.S. Air Force Contract no. F19628-TR-C-0010Ohio State Research Foundation Project no. 4214B

    Non-stationary covariance function modelling in 2D least-squares collocation

    Get PDF
    Standard least-squares collocation (LSC) assumes 2D stationarity and 3D isotropy, and relies on a covariance function to account for spatial dependence in the ob-served data. However, the assumption that the spatial dependence is constant through-out the region of interest may sometimes be violated. Assuming a stationary covariance structure can result in over-smoothing of, e.g., the gravity field in mountains and under-smoothing in great plains. We introduce the kernel convolution method from spatial statistics for non-stationary covariance structures, and demonstrate its advantage fordealing with non-stationarity in geodetic data. We then compared stationary and non-stationary covariance functions in 2D LSC to the empirical example of gravity anomaly interpolation near the Darling Fault, Western Australia, where the field is anisotropic and non-stationary. The results with non-stationary covariance functions are better than standard LSC in terms of formal errors and cross-validation against data not used in the interpolation, demonstrating that the use of non-stationary covariance functions can improve upon standard (stationary) LSC

    Field Evaluation of Calypte’s AWARE™ Blood Serum Plasma (BSP) and Oral Mucosal Transudate (OMT) Rapid Tests for Detecting Antibodies to HIV-1 and 2 in Plasma and Oral Fluid

    Get PDF
    As programs to prevent and care for HIV-infected persons are scaled-up in Africa, there is the need for continuous evaluation of the performance of test kits that could best support these programs. The present study evaluated the sensitivity, specificity, ease of use, and cost of AWARE ™ Blood Serum Plasma (BSP) and Oral Mucosal Transudate (OMT) Rapid HIV-1/2 test kits using real-time and archived samples of HIV-infected persons from Cameroon. Matched whole blood and OMT specimens were collected prospectively from HIV-positive and HIV-negative persons from different regions of Cameroon and tested using the AWARE ™ BSP and OMT test kits, respectively. These results were compared to the gold standard that included a combination of Determine HIV-1/2 and Enzygnost HIV-1/2. The BSP Rapid test kit was further evaluated using well characterized panels of HIV-2 and HIV-1 group O samples. Cost and end-user analysis of the OMT test kit was done by comparing its actual cost, consumables, safety, bench time and manipulation with other test kits. Of the 732 matched samples, 412 (56.3%) and 320 (43.7%) were from females and males, respectively. Of these samples, 23 (3.1%) gave discordant results between Determine HIV-1/2 and Enzygnost HIV1/2 and were excluded from the analysis. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the AWARE™ BSP were 100%. The AWARE™ OMT had 98.8% sensitivity, 98.9% specificity, 98.0% PPV and 99.4% NPV. The results of a well-characterized archived panel of HIV-2 (n=7) and HIV-1 group O (n=3) samples using the AWARE™ BSP Rapid test kit gave 100% concordance. Total per patient cost of the AWARE OMT rapid test kit was US4.72comparedtoameancostofUS4.72 compared to a mean cost of US 7.33 ± 0.11 for the other test kits. Both the AWARE™ BSP and OMT Rapid test kits demonstrated high sensitivities and specificities on all samples tested and were well adapted for use in resource-constrained settings with high HIV heterogeneity such as Cameroon. The AWARE ™ HIV-1/2 OMT Rapid test kit appears to be the cheapest, safest and easiest to use compared with other available test kits
    corecore