7,122 research outputs found
The Discovery of an X-ray/UV Stellar Flare from the Late-K/Early-M Dwarf LMC 335
We report the discovery of an X-ray/UV stellar flare from the source LMC 335,
captured by XMM-Newton in the field of the Large Magellanic Cloud. The flare
event was recorded continuously in X-ray for its first 10 hours from the
precursor to the late decay phases. The observed fluxes increased by more than
two orders of magnitude at its peak in X-ray and at least one in the UV as
compared to quiescence. The peak 0.1-7.0 keV X-ray flux is derived from the
two-temperature APEC model to be ~(8.4 +/- 0.6) x 10^-12 erg cm-2 s-1.
Combining astrometric information from multiple X-ray observations in the
quiescent and flare states, we identify the NIR counterpart of LMC 335 as the
2MASS source J05414534-6921512. The NIR color relations and spectroscopic
parallax characterize the source as a Galactic K7-M4 dwarf at a foreground
distance of (100 - 264) pc, implying a total energy output of the entire event
of ~(0.4 - 2.9) x 10^35 erg. This report comprises detailed analyses of this
late-K / early-M dwarf flare event that has the longest time coverage yet
reported in the literature. The flare decay can be modeled with two exponential
components with timescales of ~28 min and ~4 hours, with a single component
decay firmly ruled out. The X-ray spectra during flare can be described by two
components, a dominant high temperature component of ~40-60MK and a low
temperature component of ~10MK, with a flare loop length of about 1.1-1.3
stellar radius.Comment: 35 pages, 6 figures, 5 tables, accepted for publication in Ap
All-optical high speed NOR gate based on two photon absorption in silicon wire waveguides
We demonstrate for the first time an all-optical logic NOR gate in submicron size silicon wire waveguides. High speed operation at equivalent 80Gbps data rate was achieved using pump induced non-degenerate two-photon absorption inside the waveguides. The device requires low pulse energy (few pJ) for logic gate operation. (C) 2005 Optical Society of America
A study of primary dental enamel from preterm and full-term children using light and scanning electron microscopy
Purpose: The aim of this study was to examine the enamel thickness of the maxillary primary incisors of preterm children with very low birth weight (< 1,500 g) compared to full-term children with normal birth weight. Methods: A total of 90 exfoliated maxillary primary central incisors were investigated using light microscopy and scanning electron microscopy (SEM). Three serial buccolingual ground sections of each tooth were examined under light microscopy, and maximum dimensions of the prenatally and postnatally formed enamel were measured. Results: The enamel of preterm teeth was approximately 20% thinner than that for fullterm teeth. Most of the reduction was observed in the prenatally formed enamel. This was 5 to 13 times thinner than that for full-term children (P < .001). The catch-up thickness of postnatally formed enamel did not compensate fully for the decrease in prenatal enamel (P < .001). Although none of the teeth used in this study had enamel defects visible to the naked eye, 52% of preterm teeth showed enamel hypoplasia under SEM, compared with only 16% found on full-term teeth (P < .001). These defects were present as pits or irregular, shallow areas of missing enamel. Conclusions: Preterm primary dental enamel is abnormal in surface quality, and is significantly thinner compared to full-term enamel. The thinner enamel is due mainly to reduced prenatal growth and results in smaller dimensions of the primary dentition
Space Shuttle/TDRSS communication and tracking systems analysis
In order to evaluate the technical and operational problem areas and provide a recommendation, the enhancements to the Tracking and Data Delay Satellite System (TDRSS) and Shuttle must be evaluated through simulation and analysis. These enhancement techniques must first be characterized, then modeled mathematically, and finally updated into LinCsim (analytical simulation package). The LinCsim package can then be used as an evaluation tool. Three areas of potential enhancements were identified: shuttle payload accommodations, TDRSS SSA and KSA services, and shuttle tracking system and navigation sensors. Recommendations for each area were discussed
Variational method and duality in the 2D square Potts model
The ferromagnetic q-state Potts model on a square lattice is analyzed, for
q>4, through an elaborate version of the operatorial variational method. In the
variational approach proposed in the paper, the duality relations are exactly
satisfied, involving at a more fundamental level, a duality relationship
between variational parameters. Besides some exact predictions, the approach is
very effective in the numerical estimates over the whole range of temperature
and can be systematically improved.Comment: 20 pages, 5 EPS figure
Relationship between threshold and suprathreshold perception of position and stereoscopic depth.
We seek to determine the relationship between threshold and suprathreshold perception for position offset and stereoscopic depth perception under conditions that elevate their respective thresholds. Two threshold-elevating conditions were used: (1) increasing the interline gap and (2) dioptric blur. Although increasing the interline gap increases position (Vernier) offset and stereoscopic disparity thresholds substantially, the perception of suprathreshold position offset and stereoscopic depth remains unchanged. Perception of suprathreshold position offset also remains unchanged when the Vernier threshold is elevated by dioptric blur. We show that such normalization of suprathreshold position offset can be attributed to the topographical-map-based encoding of position. On the other hand, dioptric blur increases the stereoscopic disparity thresholds and reduces the perceived suprathreshold stereoscopic depth, which can be accounted for by a disparity-computation model in which the activities of absolute disparity encoders are multiplied by a Gaussian weighting function that is centered on the horopter. Overall, the statement equal suprathreshold perception occurs in threshold-elevated and unelevated conditions when the stimuli are equally above their corresponding thresholds describes the results better than the statement suprathreshold stimuli are perceived as equal when they are equal multiples of their respective threshold values
- …