720 research outputs found

    Electrofusion welding and reinforced thermoplastic pipes – A review

    Get PDF
    Oil and gas operators have been looking for a more reliable and cost-effective material for their pipelines to substitute steel in pipes and connectors. Reinforced thermoplastic pipes are a popular choice for this purpose, but they are still mainly using steel connectors, which have limited lifetimes due to corrosion. For this reason, efforts are being made to design a non-metallic electrofusion coupler to connect these. This article looks at the current state of the art in electrofusion welding of standard polyethylene pipes and aims to find possibilities of applying this technology to reinforced thermoplastic pipes

    Outdoor performance monitoring of perovskite solar cell mini-modules: Diurnal performance, observance of reversible degradation and variation with climatic performance

    Get PDF
    The outdoor performance monitoring of two types of perovskite solar cell (PSC) mini-modules based on two different absorbers - CH3NH3PbI3 (MAPI) and Cs0.05FA0.83MA0.17PbI(0.87Br0.13)3 (FMC) is reported. PSC modules displayed markedly different outdoor performance characteristics to other PV technologies owing to the reversible diurnal changes in efficiency, difference in temperature coefficient between absorber layers and response under low light conditions. Examination of diurnal performance parameters on a sunny day showed that whereas the FMC modules maintained their efficiency throughout the day, the MAPI modules peaked in performance during the morning and afternoon, with a strong decrease around midday. Overall, the MAPI modules showed a strongly negative temperature coefficient (TC) for PCE, whereas the FMC modules showed a moderate positive temperature coefficient performance as a function of temperature due to the increase in JSC and FF. Outdoor monitoring of the MAPI modules over several days highlighted that the reduced over the course of the day but recovered overnight. In contrast the FMC modules improved slightly during the daytime although this was too reversed overnight. This paper provides insight into how PSC modules perform under real-life conditions and consider some of the unique characteristics that are observed in this solar cell technology

    Soft robotic snake with variable stiffness actuation

    Get PDF
    © Springer International Publishing AG 2017. In this paper, we present a prototype of a 3D printed snake-like robot for search and rescue applications, inspired by biological snake anatomy and locomotion. Unlike traditional robotics, this design takes advantage of soft materials to create a robot that is resilient to shock impacts, such as from falling debris or unsound flooring, and that can very its stiffness. The robot uses a flexible spine to connect multiple sections, allowing controlled actuation while providing a sturdy structure. Variable stiffness actuation is implemented through the use of elastic materials to act as tendons for the body, in an agonist-antagonist setup. Actuation occurs through the use of Robotis Dynamixel AX-12A servos, controlled by a Trossen Robotics Arbotix-M Robocon-troller. The design features a head, containing a Raspberry Pi 3 and a Pi Camera Module. This added embedded computation can connect to a remote PC via wireless communication, allowing an operator to control the robot. This paper discusses the design and early stage testing for the prototype, and shows that robots based on soft 3D printed materials and mechanisms are viable, and effective

    The Effect of Token Economies on Student Behavior in the Preschool Classroom: A Meta-Analysis

    Get PDF
    There has been a recent push in the literature to identify and use more evidence-based practices for positive behavioral supports for challenging student behaviors in the classroom environment. Further, interest in targeting early education environments such as preschool has been growing given the persistence of behavioral difficulties in the absence of early and effective intervention (Campbell & Ewing, 1990; Kazdin, 1987; Powell et al., 2006; Stormont, 2002). Two previous meta-analyses (Maggin et al., 2011; Soares et al., 2016) provided some initial support for effectiveness of token economies with challenging student behavior; however, the inclusion of the preschool setting was limited and both studies used older versions of design standards to evaluate the quality of studies in the literature. The present study served to extend those meta-analyses by targeting preschool classrooms. Further, the current study included the most recent What Works Clearinghouse Design Standards to evaluate whether token economies meet criteria as an evidence-based practice. Ten studies were included in the final analyses. Two sets of effect sizes were calculated: Baseline-Corrected Tau and Hedge’s g. An omnibus effect size showed an overall large effect; however, similar to previous meta-analyses, several methodological concerns were identified. Moderator analyses for several variables were conducted; however, no moderator analyses were significant. Limitations and future directions were discussed

    The utility of presentation and 4-hour high sensitivity troponin I to rule-out acute myocardial infarction in the emergency department

    Get PDF
    Objectives: International guidance recommends that early serial sampling of high sensitivity troponin be used to accurately identify acute myocardial infarction (AMI) in chest pain patients. The background evidence for this approach is limited. We evaluated whether on presentation and 4-hour high-sensitivity troponin I (hs-cTnI) could be used to accurately rule-out AMI. Design and methods: hs-cTnI was measured on presentation and at 4-hours in adult patients attending an emergency department with possible acute coronary syndrome. We determined the sensitivity for AMI for at least one hs-cTnI above the 99th percentile for a healthy population or alone or in combination with new ischemic ECG changes. Both overall and sex-specific 99th percentiles were assessed. Patients with negative tests were designated low-risk. Results: 63 (17.1%) of 368 patients had AMI. The median (interquartile range) time from symptom onset to first blood sampling was 4.8. h (2.8-8.6). The sensitivity of the presentation and 4. h hs-cTnI using the overall 99th percentile was 92.1% (95% CI 82.4% to 97.4%) and negative predictive value 95.4% (92.3% to 97.4%) with 78.3% low-risk. Applying the sex-specific 99th percentile did not change the sensitivity. The addition of ECG did not change the sensitivity. Conclusion: Hs-cTnI >. 99th percentile thresholds measured on presentation and at 4-hours was not a safe strategy to rule-out AMI in this clinical setting irrespective of whether sex-specific 99th percentiles were used, or whether hs-cTnI was combined with ECG results

    Monitoring of biomarkers in heart failure.

    Get PDF
    The role of biomarkers is increasingly recognized in heart failure (HF) management, for diagnosis, prognostication, and screening of high-risk patients. Beyond natriuretic peptides and troponins, the utility of novel, emerging biomarkers is less established. This document reflects the key points of a Heart Failure Association of the European Society of Cardiology (ESC) consensus meeting on biomarker monitoring in HF

    Heart Fatty Acid Binding Protein and cardiac troponin: development of an optimal rule-out strategy for acute myocardial infarction

    Get PDF
    Background: Improved ability to rapidly rule-out Acute Myocardial Infarction (AMI) in patients presenting with chest pain will promote decongestion of the Emergency Department (ED) and reduce unnecessary hospital admissions. We assessed a new commercial Heart Fatty Acid Binding Protein (H-FABP) assay for additional diagnostic value when combined with cardiac troponin (using a high sensitivity assay). Methods: H-FABP and high-sensitivity troponins I (hs-cTnI) and T (hs-cTnT) were measured in samples taken on-presentation from patients, attending the ED, with symptoms triggering investigation for possible acute coronary syndrome. The optimal combination of H-FABP with each hs-cTn was defined as that which maximized the proportion of patients with a negative test (low-risk) whilst maintaining at least 99 % sensitivity for AMI. A negative test comprised both H-FABP and hs-cTn below the chosen threshold in the absence of ischemic changes on the ECG. Results: One thousand seventy-nine patients were recruited including 248 with AMI. H-FABP 99 % sensitivity for AMI whilst classifying 40.9 % of patients as low-risk. The combination of H-FABP < 3.9 ng/mL and hs-cTnT < 7.6 ng/L with a negative ECG maintained the same sensitivity whilst classifying 32.1 % of patients as low risk. Conclusions: In patients requiring rule-out of AMI, the addition of H-FABP to hs-cTn at presentation (in the absence of new ischaemic ECG findings) may accelerate clinical diagnostic decision making by identifying up to 40 % of such patients as low-risk for AMI on the basis of blood tests performed on presentation. If implemented this has the potential to significantly accelerate triaging of patients for early discharge from the ED

    Betaine and Secondary Events in an Acute Coronary Syndrome Cohort

    Get PDF
    BACKGROUND: Betaine insufficiency is associated with unfavourable vascular risk profiles in metabolic syndrome patients. We investigated associations between betaine insufficiency and secondary events in acute coronary syndrome patients. METHODS: Plasma (531) and urine (415) samples were collected four months after discharge following an acute coronary event. Death (34), secondary acute myocardial infarction (MI) (70) and hospital admission for heart failure (45) events were recorded over a median follow-up of 832 days. PRINCIPAL FINDINGS: The highest and lowest quintiles of urinary betaine excretion associated with risk of heart failure (p = 0.0046, p = 0.013 compared with middle 60%) but not with subsequent acute MI. The lowest quintile of plasma betaine was associated with subsequent acute MI (p = 0.014), and the top quintile plasma betaine with heart failure (p = 0.043), especially in patients with diabetes (p<0.001). Top quintile plasma concentrations of dimethylglycine (betaine metabolite) and top quintile plasma homocysteine both associated with all three outcomes, acute MI (p = 0.004, <0.001), heart failure (p = 0.027, p<0.001) and survival (p<0.001, p<0.001). High homocysteine was associated with high or low betaine excretion in >60% of these subjects (p = 0.017). Median NT-proBNP concentrations were lowest in the middle quintile of plasma betaine concentration (p = 0.002). CONCLUSIONS: Betaine insufficiency indicates increased risk of secondary heart failure and acute MI. Its association with elevated homocysteine may partly explain the disappointing results of folate supplementation. In some patients, especially with diabetes, elevated plasma betaine also indicates increased risk
    corecore