3 research outputs found

    A Multicenter Randomized Controlled Trial of Zephyr Endobronchial Valve Treatment in Heterogeneous Emphysema (TRANSFORM)

    Get PDF
    Rationale: Single-center randomized controlled trials of the Zephyr endobronchial valve (EBV) treatment have demonstrated benefit in severe heterogeneous emphysema. This is the first multicenter study evaluating this treatment approach. Objectives: To evaluate the efficacy and safety of Zephyr EBVs in patients with heterogeneous emphysema and absence of collateral ventilation. Methods: This was a prospective, multicenter 2:1 randomized controlled trial of EBVs plus standard of care or standard of care alone (SoC). Primary outcome at 3 months post-procedure was the percentage of subjects with FEV1 improvement from baseline of 12% or greater. Changes in FEV1, residual volume, 6-minute-walk distance, St. George's Respiratory Questionnaire score, and modified Medical Research Council score were assessed at 3 and 6 months, and target lobe volume reduction on chest computed tomography at 3 months. Measurements and Main Results: Ninety seven subjects were randomized toEBV(n = 65) or SoC(n = 32). At 3 months, 55.4% of EBV and 6.5% of SoC subjects had an FEV1 improvement of 12% or more (P <0.001). Improvements were maintained at 6 months: EBV 56.3% versus SoC 3.2% (P <0.001), with a mean +/- SD change in FEV1 at 6 months of 20.7 +/- 29.6% and -8.6 +/- 13.0%, respectively. A total of 89.8% of EBV subjects had target lobe volume reduction greater than or equal to 350 ml, mean 1.09 +/- 0.62 L (P <0.001). Between-group differences for changes at 6 months were statistically and clinically significant: Delta EBV-SoC for residual volume, -700 ml; 6-minute-walk distance, +78.7 m; St. George's Respiratory Questionnaire score, -6.5 points; modified Medical Research Council dyspnea score, -0.6 points; and BODE(body mass index, airflow obstruction, dyspnea, and exercise capacity) index, 21.8 points (all P <0.05). Pneumothorax was the most common adverse event, occurring in 19 of 65 (29.2%) of EBV subjects. Conclusions: EBV treatment in hyperinflated patients with heterogeneous emphysema without collateral ventilation resulted in clinically meaningful benefits in lung function, dyspnea, exercise tolerance, and quality of life, with an acceptable safety profile

    Reduced survival in patients with ALS with upper airway obstructive events on non-invasive ventilation

    No full text
    International audienceIntroduction Non-invasive ventilation (NIV) is part of standard care in amyotrophic lateral sclerosis (ALS). Intolerance or unavailability of NIV, as well as the quality of correction of nocturnal hypoventilation, has a direct impact on prognosis.Objectives We describe the importance of NIV failure due to upper airway obstructive events, the clinical characteristics, as well as their impact on the prognosis of ALS.Methods Retrospective analysis of the data of 190 patients with ALS and NIV in a single centre for the period 2011–2014. 179 patients tolerating NIV for more than 4 h per night without leaks were analysed.Results Among the 179 patients, after correction of leaks, 73 remained inadequately ventilated at night (defined as more than 5% of the night spent at <90% of SpO2), as a result of obstructive events in 67% of cases (n=48). Patients who remained inadequately ventilated after optimal adjustment of ventilator settings presented with shorter survival than adequately ventilated patients. Unexpectedly, patients with upper airway obstructive events without nocturnal desaturation and in whom no adjustment of treatment was therefore performed also presented with shorter survival. On initiation of NIV, no difference was demonstrated between patients with and without upper airway obstructive events. In all patients, upper airway obstruction was concomitant with reduction of ventilatory drive.Conclusions This study shows that upper airway obstruction during NIV occurs in patients with ALS and is associated with poorer prognosis. Such events should be identified as they can be corrected by adjusting ventilator setting
    corecore