535 research outputs found

    Regret Aversion and False Reference Points in Residential Real Estate

    Get PDF
    This study empirically exams the combination of regret aversion and false reference points in a residential real estate context. Survey respondents were put in a hypothetical situation, where they had purchased an investment property several years ago. Hindsight knowledge about a foregone all time high was introduced. As hypothesized, respondents on average expressed higher regret if they had actively failed to sell at the all time high (commission scenario) than if they had simply been unaware of the potential gain (omission scenario). Women were found to be more susceptible to regret aversion and false reference points than men.

    Phosphine Functionalization of GaAs(111)A Surfaces

    Get PDF
    Phosphorus-functionalized GaAs surfaces have been prepared by exposure of Cl-terminated GaAs(111)A surfaces to triethylphosphine (PEt3) or trichlorophosphine (PCl3), or by the direct functionalization of the native-oxide terminated GaAs(111)A surface with PCl3. The presence of phosphorus on each functionalized surface was confirmed by X-ray photoelectron spectroscopy. High-resolution, soft X-ray photoelectron spectroscopy was used to evaluate the As and Ga 3d regions of such surfaces. On PEt3 treated surfaces, the Ga 3d spectra exhibited a bulk Ga peak as well as peaks that were shifted to 0.35, 0.92 and 1.86 eV higher binding energy. These peaks were assigned to residual Cl-terminated Ga surface sites, surficial Ga2O and surficial Ga2O3, respectively. For PCl3-treated surfaces, the Ga 3d spectra displayed peaks ascribable to bulk Ga(As), Ga2O, and Ga2O3, as well as a peak shifted 0.30 eV to higher binding energy relative to the bulk signal. A peak corresponding to Ga(OH)3, observed on the Cl-terminated surface, was absent from all of the phosphine-functionalized surfaces. After reaction of the Cl-terminated GaAs(111)A surface with PCl3 or PEt3, the As 3d spectral region was free of As oxides and As0. Although native oxide-terminated GaAs surfaces were free of As oxides after reaction with PCl3, such surfaces contained detectable amounts of As0. Photoluminescence measurements indicted that phosphine-functionalized surfaces prepared from Cl-terminated GaAs(111)A surfaces had better electrical properties than the native-oxide capped GaAs(111)A surface, while the native-oxide covered surface treated with PCl3 showed no enhancement in PL intensity

    Expressive aphasia in a patient with recent dual-chamber cardioverter-defibrillator implantation: A preventable complication

    Get PDF
    Transvenous pacemaker and/or defibrillator lead placement into the left heart chambers is rarely done. Approximately a third of such cases reported in the literature presented with signs of thromboembolism, mostly neurological deficits. We describe a patient who presented with a cerebrovascular accident three months after inadvertent and unrecognized lead placement into the left atrium and ventricle through a sinus venosus atrial septal defect. Implant techniques to avoid this complication are discussed. (Cardiol J 2011; 18, 2: 197-199

    Phase Determination from Mostly One-sided Interferograms

    Get PDF
    We show how to detect and correct for non-linear phase shifts in a mainly one-sided interferogram of an emission-line source. We simultaneously detect and correct for an out-of-phase emission background from the spectrometer. The method requires two auxiliary spectra, one of a strong continuum source, and one of an emission-line source with little or no continuum

    Antiarrhythmic effect of ischemic preconditioning during low-flow ischemia: The role of bradykinin and sarcolemmal versus mitochondrial ATP-sensitive K+ channels

    Get PDF
    Abstract. : Short episodes of ischemia (ischemic preconditioning) protect the heart against ventricular arrhythmias during zero-flow ischemia and reperfusion. However, in clinics, many episodes of ischemia present a residual flow (low-flow ischemia). Here we examined whether ischemic preconditioning protects against ventricular arrhythmias during and after a low-flow ischemia and, if so, by what mechanism(s). Isolated rat hearts were subjected to 60 min of low-flow ischemia (12% residual coronary flow) followed by 60 min of reperfusion. Ischemic preconditioning was induced by two cycles of 5 min of zero-flow ischemia followed by 5 and 15 min of reperfusion, respectively. Arrhythmias were evaluated as numbers of ventricular premature beats (VPBs) as well as incidences of ventricular tachycardia (VT) and ventricular .brillation (VF) during low-flow ischemia and reperfusion. Ischemic preconditioning significantly reduced the number of VPBs and the incidence of VT and of VF during low-flow ischemia. This antiarrhythmic effect of preconditioning was abolished by HOE 140 (100 nM), a bradykinin B2 receptor blocker. Similar to preconditioning, exogenous bradykinin (10 nM) reduced the number of VPBs and the incidence of VT and of VF during low-flow ischemia. Furthermore, the antiarrhythmic effects of both ischemic preconditioning and bradykinin were abolished by glibenclamide (1 ĀµM), a non-specific blocker of ATP-sensitive K+ (KATP) channels. Finally, the antiarrhythmic effects of both ischemic preconditioning and bradykinin were abolished by HMR 1098 (10 ĀµM), a sarcolemmal KATP channel blocker but not by 5-hydroxydecanoate (100 ĀµM), a mitochondrial KATP channel blocker. In conclusion, ischemic preconditioning protects against ventricular arrhythmias induced by low-flow ischemia, and this protection involves activation of bradykinin B2 receptors and subsequent opening of sarcolemmal but not of mitochondrial KATP channel

    Balloon measurements of stratospheric HCl and HF by far infrared emission spectroscopy

    Get PDF
    We have analyzed atmospheric thermal emission spectra obtained with the balloon-borne FIRS-2 far infrared Fourier transform spectrometer during balloon flights from Palestine, Texas on May 12-13, 1988 and from Fort Sumner, New Mexico on September 26-27, 1989 and on July 4-5, 1990. Seven and two pure rotational transition lines in 100-205 cm(exp -1) range are analyzed for deriving vertical profiles of stratospheric HCl and HF, respectively. We obtain both the daytime and nighttime average vertical profiles from 15 to 50 km. We compare these profiles with the ones obtained in June, 1983 with the first version of FIRS spectrometer during the Balloon Intercomparison Campaign (BIC-2). BIC-2 results were revised to be consistent with the present analysis which uses the latest spectral parameters. According to our comparison results no increase is recognized for HCl but about 3 percent per year increase for HF from 1983 to 1990, assuming a linear trend. These annual increase rates are smaller than those reported by other groups. Recently Rinsland et al. (1991) and Wallace and Livingston (1991) reported long term behavior of total HCl and HF observed on Kit Peak between 1977 and 1990. As Kit Peak is located near both balloon launching sites, Palestine and Fort Sumner, we think our results are favorably comparable with theirs. Comparison results with ours and ground-based measurements will be presented and discussed
    • ā€¦
    corecore