18 research outputs found

    Search for Neutrinoless Double- β Decay with the Complete EXO-200 Dataset

    Get PDF
    A search for neutrinoless double-β decay (0νββ) in Xe136 is performed with the full EXO-200 dataset using a deep neural network to discriminate between 0νββ and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4±3.0%, and the energy resolution of the detector at the Q value of Xe136 0νββ has been improved from σ/E=1.23% to 1.15±0.02% with the upgraded detector. Accounting for the new data, the median 90% confidence level 0νββ half-life sensitivity for this analysis is 5.0×1025 yr with a total Xe136 exposure of 234.1 kg yr. No statistically significant evidence for 0νββ is observed, leading to a lower limit on the 0νββ half-life of 3.5×1025 yr at the 90% confidence level

    Search for Majoron-emitting modes of Xe 136 double beta decay with the complete EXO-200 dataset

    No full text
    © 2021 authors. Published by the American Physical Society.A search for Majoron-emitting modes of the neutrinoless double beta decay of Xe136 is performed with the full EXO-200 dataset. This dataset consists of a total Xe136 exposure of 234.1 kg·yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T1/2Xe136>4.3×1024 yr at 90% C.L. on the half-life of the spectral index n=1 Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200 and a factor of 1.6 more stringent than the previous best limit from KamLAND-Zen. This limit corresponds to a constraint on the Majoron-neutrino coupling constant of |geeM|<(0.4-0.9)×10-5. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the n=7 mode compared to the previous EXO-200 search. This search provides the most stringent limits to date on the Majoron-emitting decays of Xe136 with spectral indices n=1, 2, 3, and 7.11Nsciescopu

    Imaging individual barium atoms in solid xenon for barium tagging in nEXO

    No full text
    © 2019, The Author(s), under exclusive licence to Springer Nature Limited. Double-β-decay involves the simultaneous conversion of two neutrons into two protons, and the emission of two electrons and two neutrinos; the neutrinoless process, although not yet observed, is thought to involve the emission of the two electrons but no neutrinos. The search for neutrinoless-double-β-decay probes fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct particles. Double-β-decay detectors are large and expensive, so it is essential to achieve the highest possible sensitivity with each study, and removing spurious contributions (‘background’) from detected signals is crucial. In the nEXO neutrinoless-double-β-decay experiment, the identification, or ‘tagging’, of the 136 Ba daughter atom resulting from the double-β decay of 136 Xe provides a technique for discriminating background. The tagging scheme studied here uses a cryogenic probe to trap the barium atom in a solid xenon matrix, where the barium atom is tagged through fluorescence imaging. Here we demonstrate the imaging and counting of individual barium atoms in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser irradiates an individual atom, the fluorescence persists for about 30 seconds before dropping abruptly to the background level—a clear confirmation of one-atom imaging. Following evaporation of a barium deposit, the residual barium fluorescence is 0.16 per cent or less. Our technique achieves the imaging of single atoms in a solid noble element, establishing the basic principle of barium tagging for nEXO11Nsciescopu

    Characterization of the Hamamatsu VUV4 MPPCs for nEXO

    Get PDF
    © 2019 Elsevier B.V.In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Multi-Pixel Photon Counters (MPPC)s as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various MPPC features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. MPPCs were characterized in the range 163K≤T≤233K. At an over voltage of 3.1±0.2 V and at T=163K we report a number of Correlated Avalanches (CAs) per pulse in the 1μs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137±0.002Hz/mm2. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at T=233K for a mean wavelength of 189±7nm. At 3.6±0.2 V and 3.5±0.2 V of over voltage we report a PDE of 13.4±2.6% and 11±2%, corresponding to a saturation PDE of 14.8±2.8% and 12.2±2.3%, respectively. Both values are well below the 24% saturation PDE advertised by Hamamatsu. More generally, the second device tested at 3.5±0.2 V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF Silicon Photo-Multipliers for the final design of the nEXO detector11sciescopu

    Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

    No full text
    © 2020 Published by Elsevier B.V. Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are 1.97±0.04mm∕μs and (−0.69±0.05)%/K for liquid xenon, and 1.42±0.03mm∕μs and (+0.11±0.01)%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of 25.7±4.6 cm2/s and 149±23 cm2/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors11sci

    Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

    No full text
    Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from Th228 (2615 keV), Ra226 (1764 keV), and Co60 (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β-decay detectors

    Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

    No full text
    © 2020 IOP Publishing Ltd and Sissa Medialab. Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μm micro-cells conducted with xenon scintillation light (∼175 nm) in liquid xenon. The specular reflectivity at 15ˆ incidence of three samples of VUV4 SiPMs is found to be 30.4±1.4%, 28.6±1.3%, and 28.0±1.3%, respectively. The PDE at normal incidence differs by ±8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon11Nsciescopu

    The EXO-200 detector, part II: Auxiliary systems

    No full text
    The EXO-200 experiment searched for neutrinoless double-beta decay of 136Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.11Nsciescopu

    Characterization of the Hamamatsu VUV4 MPPCs for nEXO

    No full text
    In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Multi-Pixel Photon Counters (MPPC)s as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various MPPC features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. MPPCs were characterized in the range 163K≤T≤233K. At an over voltage of 3.1±0.2 V and at T=163K we report a number of Correlated Avalanches (CAs) per pulse in the 1μs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137±0.002Hz/mm2. Both the number of CAs and the DN rate ar

    Imaging individual barium atoms in solid xenon for barium tagging in nEXO

    No full text
    Double-β-decay involves the simultaneous conversion of two neutrons into two protons, and the emission of two electrons and two neutrinos; the neutrinoless process, although not yet observed, is thought to involve the emission of the two electrons but no neutrinos. The search for neutrinoless-double-β-decay probes fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct particles. Double-β-decay detectors are large and expensive, so it is essential to achieve the highest possible sensitivity with each study, and removing spurious contributions (‘background’) from detected signals is crucial. In the nEXO neutrinoless-double-β-decay experiment, the identification, or ‘tagging’, of the 136 Ba daughter atom resulting from the double-β decay of 136 Xe provides a technique for discriminating background. The tagging scheme studied here uses a cryogenic probe to trap the barium atom in a solid xenon matrix, where the barium atom is tagged through fluorescence imaging. Here we demonstrate the imaging and counting of individual barium atoms in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser irradiates an individual atom, the fluorescence persists for about 30 seconds before dropping abruptly to the background level—a clear confirmation of one-atom imaging. Following evaporation of a barium deposit, the residual barium fluorescence is 0.16 per cent or less. Our technique achieves the imaging of single atoms in a solid noble element, establishing the basic principle of barium tagging for nEXO
    corecore