40 research outputs found

    3D Visualisation of Navigation Catheters for Endovascular Procedures Using a 3D Hub and Fiber Optic RealShape Technology: Phantom Study Results

    No full text
    Objective: Fiber Optic RealShape (FORS) is a new technology that visualises the full three dimensional (3D) shape of guidewires using an optical fibre embedded in the device. Co-registering FORS guidewires with anatomical images, such as a digital subtraction angiography (DSA), provides anatomical context for navigating these devices during endovascular procedures. The objective of this study was to demonstrate the feasibility and usability of visualising compatible conventional navigation catheters, together with the FORS guidewire, in phantom with a new 3D Hub technology and to understand potential clinical benefits. Methods: The accuracy of localising the 3D Hub and catheter in relation to the FORS guidewire, was evaluated using a translation stage test setup and a retrospective analysis of prior clinical data. Catheter visualisation accuracy and navigation success was assessed in a phantom study where 15 interventionists navigated devices to three pre-defined targets in an abdominal aortic phantom using an Xray or computed tomography angiography (CTA) roadmap. Additionally, the interventionists were surveyed about the usability and potential benefits of the 3D Hub. Results: The location of the 3D Hub and catheter along the FORS guidewire was detected correctly 96.59% of the time. During the phantom study, all 15 interventionists successfully reached the target locations 100% of the time and the error in catheter visualisation was 0.69 mm. The interventionists agreed or strongly agreed that the 3D Hub was easy to use and the greatest potential clinical benefit over FORS is in offering interventionists choice over which catheter they used. Conclusion: This set of studies has shown that FORS guided catheter visualisation, enabled by a 3D Hub, is accurate and easy to use in a phantom setting. Further evaluation is needed to understand the benefits and limitations of the 3D Hub technology during endovascular procedures

    Chromophore based analyses of steady-state diffuse reflectance spectroscopy: current status and perspectives for clinical adoption

    No full text
    Diffuse reflectance spectroscopy is a rapidly growing technology in the biophotonics community where it has shown promise in its ability to classify different tissues. In the steady-state domain a wide spectrum of clinical applications is supported with this technology ranging from diagnostic to guided interventions. Diffuse reflectance spectra provide a wealth of information about tissue composition; however, extracting biologically relevant information from the spectra in terms of chromophores may be more useful to gain acceptance into the clinical community. The chromophores that absorb light in the visible and near infrared wavelengths can provide information about tissue composition. The key characteristics of these chromophores and their relevance in different organs and clinical applications is the focus of this review, along with translating their use to the clini

    Optical spectral surveillance of breast tissue landscapes for detection of residual disease in breast tumor margins.

    Get PDF
    We demonstrate a strategy to "sense" the micro-morphology of a breast tumor margin over a wide field of view by creating quantitative hyperspectral maps of the tissue optical properties (absorption and scattering), where each voxel can be deconstructed to provide information on the underlying histology. Information about the underlying tissue histology is encoded in the quantitative spectral information (in the visible wavelength range), and residual carcinoma is detected as a shift in the histological landscape to one with less fat and higher glandular content. To demonstrate this strategy, fully intact, fresh lumpectomy specimens (n = 88) from 70 patients were imaged intra-operatively. The ability of spectral imaging to sense changes in histology over large imaging areas was determined using inter-patient mammographic breast density (MBD) variation in cancer-free tissues as a model system. We discovered that increased MBD was associated with higher baseline β-carotene concentrations (p = 0.066) and higher scattering coefficients (p = 0.007) as measured by spectral imaging, and a trend toward decreased adipocyte size and increased adipocyte density as measured by histological examination in BMI-matched patients. The ability of spectral imaging to detect cancer intra-operatively was demonstrated when MBD-specific breast characteristics were considered. Specifically, the ratio of β-carotene concentration to the light scattering coefficient can report on the relative amount of fat to glandular density at the tissue surface to determine positive margin status, when baseline differences in these parameters between patients with low and high MBD are taken into account by the appropriate selection of threshold values. When MBD was included as a variable a priori, the device was estimated to have a sensitivity of 74% and a specificity of 86% in detecting close or positive margins, regardless of tumor type. Superior performance was demonstrated in high MBD tissue, a population that typically has a higher percentage of involved margins

    Spectral sensing for tissue diagnosis during lung biopsy procedures: The importance of an adequate internal reference and real-time feedback

    Get PDF
    Objectives: Difficulties in obtaining a representative tissue sample are a major obstacle in timely selecting the optimal treatment for patients with lung cancer or other malignancies. Having a modality to provide needle guidance and confirm the biopsy site selection could be of great clinical benefit, especially when small masses are targeted. The objective of this study was to evaluate whether diffuse reflectance spectroscopy (DRS) at the tip of a core biopsy needle can be used for biopsy site confirmation in real time, thereby enabling optimized biopsy acquisition and improving diagnostic capability. Materials and methods: We included a total of 23 patients undergoing a routine computed tomography (CT) guided transthoracic needle biopsy of a lesion suspected for lung cancer or metastatic disease. DRS measurements were acquired during needle insertion and clinically relevant parameters were extracted from the spectral data along the needle paths. Histopathology results were compared with the DRS data at the final measurement position. Results: Analysis of the collective data acquired from all enrolled subjects showed significant differences (p < 0.01) for blood content, stO2, water content, and scattering amplitude. The identified spectral contrast matched the final pathology in 20 out of 22 clinical cases that could be used for analysis, which corresponds with an overall diagnostic performance of 91%. Three cases underlined the importance of adequate reference measurements and the need for real time diagnostic feedback. Continuous real time DRS measurements performed during a biopsy procedure in one patient provided clear information with respect to the variation in tissue and allowed identification of the tumour boundary. Conclusions: The presented technology creates a basis for the design and clinical implementation of integrated fibre-optic tools for a variety of minimal invasive applications

    In vivo characterization of colorectal metastases in human liver using diffuse reflectance spectroscopy: toward guidance in oncological procedures

    Get PDF
    There is a strong need to develop clinical instruments that can perform rapid tissue assessment at the tip of smart clinical instruments for a variety of oncological applications. This study presents the first in vivo real-time tissue characterization during 24 liver biopsy procedures using diffuse reflectance (DR) spectroscopy at the tip of a core biopsy needle with integrated optical fibers. DR measurements were performed along each needle path, followed by biopsy of the target lesion using the same needle. Interventional imaging was coregistered with the DR spectra. Pathology results were compared with the DR spectroscopy data at the final measurement position. Bile was the primary discriminator between normal liver tissue and tumor tissue. Relative differences in bile content matched with the tissue diagnosis based on histopathological analysis in all 24 clinical cases. Continuous DR measurements during needle insertion in three patients showed that the method can also be applied for biopsy guidance or tumor recognition during surgery. This study provides an important validation step for DR spectroscopy-based tissue characterization in the liver. Given the feasibility of the outlined approach, it is also conceivable to make integrated fiber-optic tools for other clinical procedures that rely on accurate instrument positionin

    Percent change in each tissue parameter versus time from excision.

    No full text
    <p>Predicted values of percent change; calculated as the fitted rate of change divided by the absolute value of the fitted intercept, multiplied by time from excision. Data is from histologically-confirmed lumpectomy sites (not all outliers are shown). The median percent change at 30 minutes is noted for each parameter along with a p-value denoting the significance of the fitted slope coefficient.</p

    Nerve detection during surgery: optical spectroscopy for peripheral nerve localization

    Get PDF
    Precise nerve localization is of major importance in both surgery and regional anesthesia. Optically based techniques can identify tissue through differences in optical properties, like absorption and scattering. The aim of this study was to evaluate the potential of optical spectroscopy (diffuse reflectance spectroscopy) for clinical nerve identification in vivo. Eighteen patients (8 male, 10 female, age 53 ± 13 years) undergoing inguinal lymph node resection or resection or a soft tissue tumor in the groin were included to measure the femoral or sciatic nerve and the surrounding tissues. In vivo optical measurements were performed using Diffuse Reflectance Spectroscopy (400–1600 nm) on nerve, near nerve adipose tissue, muscle, and subcutaneous fat using a needle-shaped probe. Model-based analyses were used to derive verified quantitative parameters as concentrations of optical absorbers and several parameters describing scattering. A total of 628 optical spectra were recorded. Measured spectra reveal noticeable tissue specific characteristics. Optical absorption of water, fat, and oxy- and deoxyhemoglobin was manifested in the measured spectra. The parameters water and fat content showed significant differences (P < 0.005) between nerve and all surrounding tissues. Classification using k-Nearest Neighbor based on the derived parameters revealed a sensitivity of 85% and a specificity of 79%, for identifying nerve from surrounding tissues. Diffuse Reflectance Spectroscopy identifies peripheral nerve bundles. The differences found between tissue groups are assignable to the tissue composition and structure