302 research outputs found

    Internet Versus Mailed Questionnaires: A Randomized Comparison (2)

    Full text link
    BACKGROUND Low response rates among surgeons can threaten the validity of surveys. Internet technologies may reduce the time, effort, and financial resources needed to conduct surveys. OBJECTIVE We investigated whether using Web-based technology could increase the response rates to an international survey. METHODS We solicited opinions from the 442 surgeon–members of the Orthopaedic Trauma Association regarding the treatment of femoral neck fractures. We developed a self-administered questionnaire after conducting a literature review, focus groups, and key informant interviews, for which we used sampling to redundancy techniques. We administered an Internet version of the questionnaire on a Web site, as well as a paper version, which looked similar to the Internet version and which had identical content. Only those in our sample could access the Web site. We alternately assigned the participants to receive the survey by mail (n=221) or an email invitation to participate on the Internet (n=221). Non-respondents in the mail arm received up to three additional copies of the survey, while non-respondents in the Internet arm received up to three additional requests, including a final mailed copy. All participants in the Internet arm had an opportunity to request an emailed Portable Document Format (PDF) version. RESULTS The Internet arm demonstrated a lower response rate (99/221, 45%) than the mail questionnaire arm (129/221, 58%) (absolute difference 13%, 95% confidence interval 4%-22%, P<0.01). CONCLUSIONS. Our Internet-based survey to surgeons resulted in a significantly lower response rate than a traditional mailed survey. Researchers should not assume that the widespread availability and potential ease of Internet-based surveys will translate into higher response rates.Department of Surgery, McMaster University, Hamilton, Ontario, Canad

    Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces.</p> <p>Materials and methods</p> <p>Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed.</p> <p>Results</p> <p>All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II.</p> <p>Conclusion</p> <p>Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to restore normal movement of talus against the mortise. Both Ilizarov and hinged external fixators are unable to restore ligamentous stability. External fixation is recommended only for fractures of the ankle joint caused by axial compression because it is biomechanically superior and has a lower complication rate.</p

    A Trial of Wound Irrigation in the Initial Management of Open Fracture Wounds

    Get PDF
    Copyright © 2015 Massachusetts Medical Society. BACKGROUND The management of open fractures requires wound irrigation and dridement to remove contaminants, but the effectiveness of various pressures and solutions for irrigation remains controversial. We investigated the effects of castile soap versus normal saline irrigation delivered by means of high, low, or very low irrigation pressure. METHODS In this study with a 2-by-3 factorial design, conducted at 41 clinical centers, we randomly assigned patients who had an open fracture of an extremity to undergo irrigation with one of three irrigation pressures (high pressure [\u3e20 psi], low pressure [5 to 10 psi], or very low pressure [1 to 2 psi]) and one of two irrigation solutions (castile soap or normal saline). The primary end point was reoperation within 12 months after the index surgery for promotion of wound or bone healing or treatment of a wound infection. RESULTS A total of 2551 patients underwent randomization, of whom 2447 were deemed eligible and included in the final analyses. Reoperation occurred in 109 of 826 patients (13.2%) in the high-pressure group, 103 of 809 (12.7%) in the low-pressure group, and 111 of 812 (13.7%) in the very-low-pressure group. Hazard ratios for the three pairwise comparisons were as follows: for low versus high pressure, 0.92 (95% confidence interval [CI], 0.70 to 1.20; P = 0.53), for high versus very low pressure, 1.02 (95% CI, 0.78 to 1.33; P = 0.89), and for low versus very low pressure, 0.93 (95% CI, 0.71 to 1.23; P = 0.62). Reoperation occurred in 182 of 1229 patients (14.8%) in the soap group and in 141 of 1218 (11.6%) in the saline group (hazard ratio, 1.32, 95% CI, 1.06 to 1.66; P = 0.01). CONCLUSIONS The rates of reoperation were similar regardless of irrigation pressure, a finding that indicates that very low pressure is an acceptable, low-cost alternative for the irrigation of open fractures. The reoperation rate was higher in the soap group than in the saline group. (Funded by the Canadian Institutes of Health Research and others; FLOW ClinicalTrials.gov number, NCT00788398

    Expanding the Versatility of Phage Display II: Improved Affinity Selection of Folded Domains on Protein VII and IX of the Filamentous Phage

    Get PDF
    Background: Phage display is a leading technology for selection of binders with affinity for specific target molecules. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII) or the minor coat protein III (pIII). Whereas pVIII display suffers from drawbacks such as heterogeneity in display levels and polypeptide fusion size limitations, toxicity and infection interference effects have been described for pIII display. Thus, display on other coat proteins such as pVII or pIX might be more attractive. Neither pVII nor pIX display have gained widespread use or been characterized in detail like pIII and pVIII display. Methodology/Principal Findings: Here we present a side-by-side comparison of display on pIII with display on pVII and pIX. Polypeptides of interest (POIs) are fused to pVII or pIX. The N-terminal periplasmic signal sequence, which is required for phage integration of pIII and pVIII and that has been added to pVII and pIX in earlier studies, is omitted altogether. Although the POI display level on pIII is higher than on pVII and pIX, affinity selection with pVII and pIX display libraries is shown to be particularly efficient. Conclusions/Significance: Display through pVII and/or pIX represent platforms with characteristics that differ from those of the pIII platform. We have explored this to increase the performance and expand the use of phage display. In the paper, we describe effective affinity selection of folded domains displayed on pVII or pIX. This makes both platforms more attractive alternatives to conventional pIII and pVIII display than they were before. © 2011 Wälchli et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited

    Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure.</p> <p>Methods</p> <p>The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.</p> <p>Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests.</p> <p>Results</p> <p>A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (<it>p </it>< 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (<it>p </it>= 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (<it>p </it>= 0.018).</p> <p>Conclusions</p> <p>In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.</p

    Low infection rates after 34,361 intramedullary nail operations in 55 low- and middle-income countries: Validation of the Surgical Implant Generation Network (SIGN) Online Surgical Database

    Get PDF
    Background: The Surgical Implant Generation Network (SIGN) supplies intramedullary (IM) nails for the treatment of long bone fractures free of charge to hospitals in low- and middle-income countries (LMICs). Most operations are reported to the SIGN Online Surgical Database (SOSD). Follow-up has been reported to be low, however. We wanted to examine the pattern of follow-up and to assess whether infection rates could be trusted. Patients and methods: The SOSD contained 36,454 IM nail surgeries in 55 LMICs. We excluded humerus and hip fractures, and fractures without a registered surgical approach. This left 34,361 IM nails for analysis. A generalized additive regression model (gam) was used to explore the association between follow-up rates and infection rates. Results: The overall follow-up rate in the SOSD was 18.1% (95% CI: 17.7–18.5) and national follow-up rates ranged from 0% to 74.2%. The overall infection rate was 0.7% (CI: 0.6–0.8) for femoral fractures and 1.2% (CI: 1.0–1.4) for tibial fractures. If only nails with a registered follow-up visit were included (n = 6,224), infection rates were 3.5% (CI: 3.0–4.1) for femoral fractures and 7.3% (CI: 6.2–8.4) for tibial fractures. We found an increase in infection rates with increasing follow-up rates up to a level of 5%. Follow-up above 5% did not result in increased infection rates. Interpretation: Reported infection rates after IM nailing in the SOSD appear to be reliable and could be used for further research. The low infection rates suggest that IM nailing is a safe procedure also in low- and middle-income countries.publishedVersio

    Treatment of displaced intra-articular calcaneal fractures by ligamentotaxis: current concepts’ review

    Get PDF
    Introduction: A large variety of therapeutic modalities for calcaneal fractures have been described in the literature. No single treatment modality for displaced intra-articular calcaneal fractures has proven superior over the other. This review describes and compares the different percutaneous distractional approaches for intra-articular calcaneal fractures. The history, technique, anatomical and fracture considerations, limitations and the results of different distractional approaches reported in the literature are reviewed. Method: Literature review on different percutaneous distractional approaches for displaced intra-articular calcaneal fractures. Results: Eight studies in which application of a distraction technique was used for the treatment of calcaneal fractures were identified. Because of the use of different classification, techniques, and outcome scoring systems, a meta-analysis was not possible. A literature review reveals overall fair to poor result in 10-29% of patients. Ten up to 26% of patients are unable to return to work after percutaneous treatment of their fracture. A secondary arthrodesis has to be performed in 2-15% of the cases. Infectious complications occur in 2-15%. Some loss of reduction is reported in 4-67%. Conclusion: Percutaneous distractional reduction and fixation appears to be a safe technique with overall good results and an acceptable complication rate, compared with other treatment modalities for displaced intra-articular calcaneal fractures. A meta-analysis, based on Cochrane Library criteria is not possible, because of a lack of level 1 and 2 trials on this subject
    corecore