45 research outputs found

    The Year in Imaging Related to Electrophysiology

    Get PDF

    Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology

    Get PDF
    As a consequence of improved technology, there is growing clinical interest in the use of multi-detector row computed tomography (MDCT) for non-invasive coronary angiography. Indeed, the accuracy of MDCT to detect or exclude coronary artery stenoses has been high in many published studies. This report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT (WG 5) of the European Society of Cardiology and the European Council of Nuclear Cardiology summarizes the present state of cardiac CT technology, as well as the currently available data concerning its accuracy and applicability in certain clinical situations. Besides coronary CT angiography, the use of CT for the assessment of cardiac morphology and function, evaluation of perfusion and viability, and analysis of heart valves is discussed. In addition, recommendations for clinical applications of cardiac CT imaging are given and limitations of the technique are describe

    Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography Implications for Transcatheter Aortic Valve Replacement

    Get PDF
    ObjectivesIn the present study, the anatomy of the aortic root was assessed noninvasively with multislice computed tomography (MSCT).BackgroundTranscatheter aortic valve replacement has been proposed as an alternative to surgery in high-risk patients with severe aortic stenosis. For this procedure, detailed knowledge of aortic annulus diameters and the relation between the annulus and the coronary arteries is needed.MethodsIn 169 patients (111 men, age 54 ± 11 years), a 64-slice MSCT scan was performed for evaluation of coronary artery disease. Of these, 150 patients had no or mild aortic stenosis, and 19 patients had moderate to severe aortic stenosis. Reconstructed coronal and sagittal views were used for assessment of the aortic annulus diameter in 2 directions. In addition, the distance between the annulus and the ostium of the right and left coronary arteries and the length of the coronary leaflets were assessed. The LV outflow tract and interventricular septum were analyzed on the single oblique sagittal view at end-diastole.ResultsThe diameter of the aortic annulus was 26.3 ± 2.8 mm on the coronal view, and 23.5 ± 2.7 mm on the sagittal view. Mean difference between the 2 diameters was 2.9 ± 1.8 mm, indicating an oval shape of the aortic annulus. Mean distance between the aortic annulus and the ostium of the right coronary artery was 17.2 ± 3.3 mm, and mean distance between the annulus and the ostium of the left coronary artery was 14.4 ± 2.9 mm. In 82 patients (49%), the length of the left coronary leaflet exceeded the distance between the annulus and the ostium of the left coronary artery. There were no significant differences in the diameter of annulus, diameter of sinus of Valsalva, or the distance between the annulus, left coronary leaflet, and the ostium of the left coronary artery, between the patient with and without severe aortic stenosis.ConclusionsThe MSCT can provide detailed information on the shape of the aortic annulus and the relation between the annulus and the ostia of the coronary arteries. Thereby, MSCT may be helpful for avoiding paravalvular leakage and coronary occlusion and may facilitate the selection of candidates for transcatheter aortic valve replacement

    The European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery:third report

    Get PDF
    OBJECTIVES: In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. METHODS: Procedures in adult patients (January 2011-June 2020) were included. Patients from centres with 3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (3 months). RESULTS: In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3-2.6) years. The annual number of implants (range: 346-600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4-7: 23, 25 and 33%; P 3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. CONCLUSIONS: In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent

    Inotropic therapy in patients with advanced heart failure. A clinical consensus statement from the Heart Failure Association of the European Society of Cardiology

    Get PDF
    This clinical consensus statement reviews the use of inotropic support in patients with advanced heart failure. The current guidelines only support use of inotropes in the setting of acute decompensated heart failure with evidence of organ malperfusion or shock. However, inotropic support may be reasonable in other patients with advanced heart failure without acute severe decompensation. The clinical evidence supporting use of inotropes in these situations is reviewed. Particularly, patients with persistent congestion, systemic hypoperfusion, or advanced heart failure with need for palliation, and specific situations relevant to implantation of left ventricular assist devices or heart transplantation are discussed. Traditional and novel drugs with inotropic effects are discussed and use of guideline-directed therapy during inotropic support is reviewed. Finally, home inotropic therapy is described, and palliative care and end-of-life aspects are reviewed in relation to management of ongoing inotropic support (including guidance for maintenance and weaning of chronic inotropic therapy support)

    Mechanism of improvement in mitral regurgitation after cardiac resynchronization therapy.

    Full text link
    AIMS: The aim of the current study was to evaluate the relationship between the presence of left ventricular (LV) dyssynchrony at baseline and acute vs. late improvement in mitral regurgitation (MR) after cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Sixty eight patients consecutive (LV ejection fraction 23 +/- 8%) with at least moderate MR (>or=grade 2+) were included. Echocardiography was performed at baseline, 1 day after CRT initiation and at 6 months follow-up. Speckle tracking radial strain was used to assess LV dyssynchrony at baseline. The majority of patients improved in MR after CRT, with 43% improving immediately after CRT, and 20% improving late (after 6 months) after CRT. Early and late responders had similar extent of LV dyssynchrony (209 +/- 115 ms vs. 190 +/- 118 ms, P = NS); however, the site of latest activation in early responders was mostly inferior or posterior (adjacent to the posterior papillary muscle), whereas the lateral wall was the latest activated segment in late responders. CONCLUSION: Current data suggest that the presence of baseline LV dyssynchrony is related to improvement in MR after CRT. LV dyssynchrony involving the posterior papillary muscle may lead to an immediate reduction in MR, whereas LV dyssynchrony in the lateral wall resulted in late response to CRT

    Multi‐modality imaging to assess left atrial size, anatomy and function

    No full text
    The left atrium (LA) anterior–posterior diameter was one of the first standardised echocardiographic parameters. However, the clinical importance of LA size assessment has been neglected for some time. Recent population‐based studies have demonstrated the prognostic value of LA size for long‐term outcome. Furthermore, with new dedicated techniques such as tissue Doppler imaging, it has become feasible to assess (regional) LA function. In addition, the introduction of catheter ablation procedures has changed the treatment of patients with drug‐refractory atrial fibrillation (AF) dramatically. New image integration systems have become available for these catheter ablation procedures. With the use of image integration systems, a real anatomical “roadmap” of the LA is provided for catheter ablation procedures. All these factors may explain the renewed interest in LA anatomy

    Impact of recurrent mitral regurgitation after mitral valve repair for functional mitral regurgitation: Long-term analysis of competing outcomes

    No full text
    Aims Recurrent mitral regurgitation (MR) has been reported after mitral valve repair for functional MR. However, the impact of recurrent MR on long-term survival remains poorly defined. In the present study, mortality-adjusted recurrent MR rates, the clinical impact of recurrent MR and its determinants were studied in patients after mitral valve repair with revascularization for functional MR in the setting of ischaemic heart disease. Methods and results Long-term clinical and echocardiographic outcome was evaluated in 261 consecutive patients after restrictive mitral annuloplasty and revascularization for moderate to severe functional MR, between 2000 and 2014. The cumulative incidence of recurrent MR ≄ Grade 2, assessed by competing risk analysis, was 9.6 ± 1.8% at 1-year, 20.3 ± 2.5% at 5-year, and 27.6 ± 2.9% at 10-year follow-up. Cumulative survival was 85.8% [95% confidence interval (CI) 81.0–90.0] at 1-year, 67.3% (95% CI 61.1–72.6%) at 5-year, and 46.1% (95% CI 39.4–52.6%) at 10-year follow-up. Age, preoperative New York Heart Association Class III or IV, a history of renal failure, and recurrence of MR expressed as a time-dependent variable [HR 3.28 (1.87–5.75), P < 0.001], were independently associated with an increased mortality risk. Female gender, a history of ST-elevation myocardial infarction, a preoperative QRS duration ≄120 ms, a higher preoperative MR grade, and a higher indexed left ventricular end-systolic volume were independently associated with an increased likelihood of recurrent MR. Conclusion Mitral valve repair for functional ischaemic MR resulted in a low incidence of recurrent MR with favourable clinical outcome up to 10 years after surgery. Presence of recurrent MR at any moment after surgery proved to be independently associated with an increased risk for mortality

    The Potential of the HeartLogic<sup>TM</sup> Algorithm in Patients with a Left Ventricular Assist Device, an Initial Report

    No full text
    Background: Survival and quality-of-life of left ventricular assist device (LVAD) recipients improved significantly because of growing experience and technological advances. However, LVAD-related complication rates, including recurrent episodes of congestion, remain high. Early detection of fluid retention to provide a time-window for medical intervention is the pillar in preventing hospitalizations. The multisensory HeartLogicTM algorithm accurately detected impending congestion in ambulant heart failure patients. The aim of the current study is to investigate the feasibility of HeartLogicTM-driven care in LVAD patients. Methods: Consecutive LVAD destination therapy patients were followed-up according the structured HeartLogicTM-based heart failure carepath. An alert triggered a device check-up, and the heart failure team contacted the patient to evaluate for signs and symptoms of impending congestion. An alert was adjudicated as true positive or unexplained. An episode of congestion not preceded by an alert was deemed as a false negative. Results: Data from 7 patients were included: the median age was 67 years [IQR 61–71], 71% were male and 71% had a non-ischemic aetiology. Total follow-up entailed 12 patient-years. All patients experienced at least one alert. In total, 33 alerts were observed. Majority of alerts (70%, n = 23) were driven by congestion and one alerts (15%) were clinically meaningful but not primarily fluid-retention-related (e.g., altered hemodynamic triggered by a pump thrombosis). Of all the alerts, five (15%) were classified as an unexplained alert, and during follow-up, four false negative episodes were documented. Conclusions: HeartLogicTM-driven care with continuous monitoring to detect impending fluid retention in LVAD patients was feasible and deserves further prospective validation
    corecore