30 research outputs found

    Terminologia para as técnicas analíticas de eletromigração em capilares

    Get PDF
    This is a contribution that presents a translation of the work Terminology for Analytical Capillary Electromigration Techniques by Riekkola and collaborators (Pure Appl. Chem., Vol. 76, No. 2, 443-451, 2004) from IUPAC© for the Portuguese Language. Additional terms that had not been defined in native Portuguese were included for the benefit of the local community. Additional notes were also included to clarify some important concepts and to highlight the differences between techniques.74074

    Role of the Carotid Bodies in the Hypertensive and Natriuretic Responses to NaCl Load in Conscious Rats

    Get PDF
    Hyperosmotic challenges trigger a hypertensive response and natriuresis mediated by central and peripheral sensors. Here, we evaluated the importance of the carotid bodies for the hypertensive and natriuretic responses to acute and sub-chronic NaCl load in conscious rats. Male Wistar rats (250–330 g) submitted to bilateral carotid body removal (CBX) or sham surgery were used. One day after the surgery, the changes in arterial blood pressure (n = 6–7/group) and renal sodium excretion (n = 10/group) to intravenous infusion of 3 M NaCl (1.8 mL/kg b.w. during 1 min) were evaluated in non-anesthetized rats. Another cohort of sham (n = 8) and CBX rats (n = 6) had access to 0.3 M NaCl as the only source of fluid to drink for 7 days while ingestion and renal excretion were monitored daily. The sodium balance was calculated as the difference between sodium infused/ingested and excreted. CBX reduced the hypertensive (8 ± 2 mmHg, vs. sham rats: 19 ± 2 mmHg; p < 0.05) and natriuretic responses (1.33 ± 0.13 mmol/90 min, vs. sham: 1.81 ± 0.11 mmol/90 min; p < 0.05) to acute intravenous infusion of 3 M NaCl, leading to an increase of sodium balance (0.38 ± 0.11 mmol/90 min, vs. sham: -0.06 ± 0.10 mmol/90 min; p < 0.05). In CBX rats, sub-chronic NaCl load with 0.3 M NaCl to drink for 7 days increased sodium balance (18.13 ± 4.45 mmol, vs. sham: 5.58 ± 1.71 mmol; p < 0.05) and plasma sodium concentration (164 ± 5 mmol/L, vs. sham: 140 ± 7 mmol/L; p < 0.05), without changing arterial pressure (121 ± 9 mmHg, vs. sham: 116 ± 2 mmHg). These results suggest that carotid bodies are important for the maintenance of the hypertensive response to acute hypertonic challenges and for sodium excretion to both acute and chronic NaCl load

    "Fabrication and Evaluation of Electrophoresis Microdevices coupled with Electrochemical Detection"

    No full text
    Este trabalho descreve o desenvolvimento de microchips para eletroforese a partir dos processos de impressão direta e fotolitográfico. A estrutura dos microcanais fabricados pelo processo de impressão direta são definidos por filmes de poliéster (base e tampa) e por uma camada de toner (paredes). A caracterização da superfície e da composição do toner foram necessárias para um melhor entendimento da composição química da estrutura dos microcanais e para este propósito foram utilizadas diferentes técnicas como análise elementar de CHN-O, AFM, EDX e MEV. Além da química do toner as dimensões limites para os canais, como largura e altura, também foram estudadas. A aplicação de um efeito de cinza nos microcanais foi avaliado de modo a desenvolver um dispositivo de pré-concentração usando as partículas de toner como obstáculos para o fluxo. Os microdispositivos fabricados em poliéster-toner foram integrados com detecção amperométrica no final do canal de separação usando eletrodos produzidos a partir da combinação das tecnologias da produção de máscaras de toner e CDs, como fonte de ouro. O desempenho destes microchips foi avaliado com detecção amperométrica da separação eletroforética de iodeto e ascorbato. Os limites de detecção obtidos foram de 500 nmol L-1 (135 amol) e 1,2 mmol L-1 (486 amol) para o iodeto e ascorbato, respectivamente. Além do processo de impressão direta, o processo fotolitográfico também foi utilizado para a mesma finalidade. Neste processo foi utilizado o fotorresiste negativo SU-8 e microdispositivos com área de 1 cm2 foram fabricados usando diferentes substratos como vidro, silício e alumina. A alumina apresentou muitas irregularidades para os microdispositivos fabricados. Problemas com a absorção e dispersão da radiação ultravioleta foram observados. No entanto, a alumina foi um excelente material para as etapas de produção de dois moldes metálicos para a rápida produção de dispositivos poliméricos. Um molde com uma geometria complexa foi obtido para estudar um novo sistema de injeção e um segundo molde foi preparado para avaliar o uso de uma borracha de silicone como material moldante. Além disso, este trabalho também apresenta o desenvolvimento de um dispositivo microfabricado com eletrodos completamente integrados para separação e detecção eletroquímica. Eletrodos de ouro ou de titânio/platina foram obtidos através da técnica lift-off. As máscaras para a fabricação de moldes metálicos e dos dispositivos integrados foram preparadas em fotolito de alta resolução.This work describes the development of electrophoresis microchip fabricated by direct-printing and photolithographic processes. The channel structures of the devices fabricated by direct-printing process are defined by polyester films (base and cover) and by a toner layer (walls). The characterization of toner surface and composition were necessary for a better understanding of the chemistry composition and for this purpose we have used different techniques such as CHN-O elemental analysis, AFM, EDX and SEM. Besides the chemistry of toner, the possible dimensions for the channels as the depth and the width were also studied. The application of a gray-scale effect in the channels was evaluated in order to create a preconcentration device using the toner particles as obstacles for the flow. The polyester-toner microdevices were coupled with end-channel amperometric detection using electrodes produced by combination of the toner masks laser-printing and compact discs as a gold source. The performance of this electrophoresis microchip was evaluated by amperometric detection of iodide and ascorbate. The detection limits found were 500 nmol L-1 (135 amol) and 1.2 mmol L-1 (486 amol) for iodide and ascorbate, respectively. Besides the direct-printing process, the photolithographic process was also used for this purpose. In this process it was used the SU-8 negative photoresist and microdevices with 1-cm2 area were fabricated using different substrates such as glass, silicon and alumina. The alumina presented several irregularities for the microdevices fabricated. Problems with the absorption and dispersion of ultraviolet radiation were observed. However, the alumina was an excellent material for the steps in the production of two metallic molds for fast production of PDMS devices. One mold with complex geometry was obtained in order to study a new injection system and a second mold was prepared to evaluate the use of silicon rubber as molding material. Furthermore, in this work it was also reported the development of a microfabricated device with fully integrated electrodes for separation and electrochemical detection. The gold or titanium/platinum electrodes were obtained by lift-off technique. The masks for fabrication of the metallic molds and of the integrated microdevices were prepared in transparency films with high resolution

    "Fabrication and Evaluation of Electrophoresis Microdevices coupled with Electrochemical Detection"

    No full text
    Este trabalho descreve o desenvolvimento de microchips para eletroforese a partir dos processos de impressão direta e fotolitográfico. A estrutura dos microcanais fabricados pelo processo de impressão direta são definidos por filmes de poliéster (base e tampa) e por uma camada de toner (paredes). A caracterização da superfície e da composição do toner foram necessárias para um melhor entendimento da composição química da estrutura dos microcanais e para este propósito foram utilizadas diferentes técnicas como análise elementar de CHN-O, AFM, EDX e MEV. Além da química do toner as dimensões limites para os canais, como largura e altura, também foram estudadas. A aplicação de um efeito de cinza nos microcanais foi avaliado de modo a desenvolver um dispositivo de pré-concentração usando as partículas de toner como obstáculos para o fluxo. Os microdispositivos fabricados em poliéster-toner foram integrados com detecção amperométrica no final do canal de separação usando eletrodos produzidos a partir da combinação das tecnologias da produção de máscaras de toner e CDs, como fonte de ouro. O desempenho destes microchips foi avaliado com detecção amperométrica da separação eletroforética de iodeto e ascorbato. Os limites de detecção obtidos foram de 500 nmol L-1 (135 amol) e 1,2 mmol L-1 (486 amol) para o iodeto e ascorbato, respectivamente. Além do processo de impressão direta, o processo fotolitográfico também foi utilizado para a mesma finalidade. Neste processo foi utilizado o fotorresiste negativo SU-8 e microdispositivos com área de 1 cm2 foram fabricados usando diferentes substratos como vidro, silício e alumina. A alumina apresentou muitas irregularidades para os microdispositivos fabricados. Problemas com a absorção e dispersão da radiação ultravioleta foram observados. No entanto, a alumina foi um excelente material para as etapas de produção de dois moldes metálicos para a rápida produção de dispositivos poliméricos. Um molde com uma geometria complexa foi obtido para estudar um novo sistema de injeção e um segundo molde foi preparado para avaliar o uso de uma borracha de silicone como material moldante. Além disso, este trabalho também apresenta o desenvolvimento de um dispositivo microfabricado com eletrodos completamente integrados para separação e detecção eletroquímica. Eletrodos de ouro ou de titânio/platina foram obtidos através da técnica lift-off. As máscaras para a fabricação de moldes metálicos e dos dispositivos integrados foram preparadas em fotolito de alta resolução.This work describes the development of electrophoresis microchip fabricated by direct-printing and photolithographic processes. The channel structures of the devices fabricated by direct-printing process are defined by polyester films (base and cover) and by a toner layer (walls). The characterization of toner surface and composition were necessary for a better understanding of the chemistry composition and for this purpose we have used different techniques such as CHN-O elemental analysis, AFM, EDX and SEM. Besides the chemistry of toner, the possible dimensions for the channels as the depth and the width were also studied. The application of a gray-scale effect in the channels was evaluated in order to create a preconcentration device using the toner particles as obstacles for the flow. The polyester-toner microdevices were coupled with end-channel amperometric detection using electrodes produced by combination of the toner masks laser-printing and compact discs as a gold source. The performance of this electrophoresis microchip was evaluated by amperometric detection of iodide and ascorbate. The detection limits found were 500 nmol L-1 (135 amol) and 1.2 mmol L-1 (486 amol) for iodide and ascorbate, respectively. Besides the direct-printing process, the photolithographic process was also used for this purpose. In this process it was used the SU-8 negative photoresist and microdevices with 1-cm2 area were fabricated using different substrates such as glass, silicon and alumina. The alumina presented several irregularities for the microdevices fabricated. Problems with the absorption and dispersion of ultraviolet radiation were observed. However, the alumina was an excellent material for the steps in the production of two metallic molds for fast production of PDMS devices. One mold with complex geometry was obtained in order to study a new injection system and a second mold was prepared to evaluate the use of silicon rubber as molding material. Furthermore, in this work it was also reported the development of a microfabricated device with fully integrated electrodes for separation and electrochemical detection. The gold or titanium/platinum electrodes were obtained by lift-off technique. The masks for fabrication of the metallic molds and of the integrated microdevices were prepared in transparency films with high resolution

    Contactless conductivity detection: a new tool for monitoring biomolecular interactions on analytical microsystems

    No full text
    O trabalho descrito nesta tese mostra a aplicação de um sistema de detecção condutométrica sem contato acoplado capacitivamente (C4D) para monitorar interações biomoleculares em microssistemas analíticos. Inicialmente, o desempenho analítico de microssistemas fabricados em vidro, poli(dimetilsiloxano) (PDMS) e poliéster-toner (PT) foi avaliado de modo a escolher o melhor material (em termos de facilidades de fabricação, custo e repetibilidade) para os ensaios biomoleculares. Dentre os materiais estudados, os dispositivos fabricados em PT mostraram-se mais adequados para testes rápidos, onde a repetibilidade analítica não é o parâmetro mais importante. Os dispositivos fabricados em PDMS e selados contra uma placa de vidro apresentaram os melhores resultados em termos de repetibilidade e o desempenho analítico foi similar aos dispositivos de vidro. Dessa maneira, os dispositivos fabricados em PDMS/vidro foram escolhidos para a demonstração dos objetivos da tese. Por outro lado, os dispositivos fabricados em PT foram explorados para estudar a configuração geométrica do sistema de C4D. A instrumentação para monitoramento dos ensaios de ligação foi composta basicamente de dois sistemas de C4D, um software escrito em LabVIEW e um sistema de bombeamento das soluções. De modo a encontrar a configuração ideal da cela de detecção, geometrias contendo três, quatro e cinco eletrodos foram avaliadas em dispositivos de PT. A configuração ótima foi composta de três eletrodos, espaçados simetricamente. Nesta geometria, um eletrodo é utilizado para aplicar o sinal senoidal de excitação e os outros dois são utilizados para capturar o sinal resultante. As dimensões dos eletrodos (largura e espaçamento entre eles) foram otimizados usando ferramentas quimométricas. O complexo avidina-biotina foi utilizado como modelo de ligação para mostrar a aplicabilidade do sistema proposto. Para os microssistemas biomoleculares, os eletrodos (com geometria otimizada) foram fabricados sobre a superfície de uma placa de vidro por fotolitografia, sputtering e lift-off. Os eletrodos de detecção foram isolados com uma camada de óxido de silício com espessura de 50 nm, depositada pelo processo de deposição química em fase de vapor assistida por plasma. A camada de SiO2 foi modificada quimicamente com solução de 3-amino-propil-trietóxi-silano em etanol. Para imobilização covalente de biotina, uma alíquota de 10 ?L de fotobiotina dissolvida em água (0,1 mg/mL) foi adicionada à superfície e exposta a radiação ultravioleta (365 nm, 10 mW/cm2) durante 15 min. A detecção foi realizada aplicando um sinal senoidal, a partir de um gerador de funções, ao eletrodo de excitação registrando o sinal resultante nos dois eletrodos receptores. Para minimizar a captura de ruído elétrico, os experimentos foram realizados em uma gaiola de Faraday. O controle e a aquisição de dados foi feito mediante um software escrito em LabVIEW monitorando os sensorgramas de condutividade em tempo real. Os canais microfluídicos foram fabricados em PDMS por litografia suave e selados irrevesivelmente contra a placa de vidro contendo os eletrodos isolados e modificados quimicamente. As soluções (tampão e amostra) foram manuseadas com auxílio de uma bomba peristáltica ou duas bombas seringas. Soluções contendo tampão e avidina foram introduzidas nos microcanais e as mudanças de conductividade foram monitoradas em função do tempo. As soluções contendo avidina permaneceram em contato com a superfície modificada até o sinal de condutividade atingir um patamar de equilíbrio. Depois disso, solução tampão foi introduzida no microcanal para remover os analitos adsorvidos à superfície. Duas válvulas solenóides foram utilizadas para permitir um controle automático da distribuição das soluções nos microcanais. O limite de detecção obtido para a interação entre avidina e biotina foi de 75 nmol L-1.The study reported in this thesis shows the application of a capacitively coupled contactless conductivity detection (C4D) for monitoring biomolecular interactions on analytical microsystems. Initially, the analytical performance of the microsystems fabricated in glass, poly(dimethylsiloxane) (PDMS) and polyester-toner (PT) was investigated in order to choose the best material (in terms of fabrication facilities, costs and repeatability) for the biomolecular assays. Among all substrate materials studied, devices fabricated in PT showed suitability for quick experiments, in which the analytical repeatability is not the most important parameter. The devices fabricated in PDMS and sealed against a glass plate presented the best results in terms of repeatability and the analytical performance was similar to that one of glass devices. For this reason, PDMS/glass devices were chosen for showing the goals of this thesis. On the other hand, PT devices were employed to study the geometrical design of the C4D system. The instrumentation for monitoring binding assays was basically composed of two C4D systems, a software written in LabVIEW and a solution pumping system. In order to find the suitable detection cell configuration for this dual-C4D system, designs containing three, four and five electrodes were evaluated on PT devices. The optimal design was composed of three electrodes symmetrically spaced. In this configuration, one electrode is used for applying an excitation sinusoidal wave and the other two for picking up the resulting signal. The dimensions of the electrodes (width and gap) were optimized by chemometric tools. The avidin-biotin complex was used as a binding model for showing the feasibility of the proposed system. For the biomolecular microsystems, electrodes were fabricated on glass surface using photolithographic, sputtering and lift-off processes. Detection electrodes were insulated with a 50-nm silicon oxide layer deposited by plasmaenhanced chemical vapor deposition. The SiO2 layer was functionalized by immersing the cleaned surface in a 3-aminopropyltriethoxy-silane solution in ethanol for 3 h. For biotinylation of the amino-silane layer, 10 ?L of photobiotin dissolved in deionized water (0.1 mg/mL) was dropped on the modified glass surface and exposed to a 365 nm UV radiation at intensity of 10 mW/cm2 for 15 min. Detection was carried out by passing a sinusoidal excitation signal from the function signal generator to the first electrode and picking up the resulting signal at the two receiver electrodes. To reduce electrical noise pickup, all measurements were carried out in a Faraday cage. The data acquisition was obtained in a software written in LabVIEW and the conductivity sensorgrams were recorded in real-time. The microfluidic network was fabricated in PDMS by soft lithography and irreversibly sealed against the electrodes plate. Solutions were handled into microfluidic channels using a peristaltic pump or two syringe pumps. Buffer and avidin-containing solution was injected into the microchannels and conductivity changes were monitored over time. Avidin solutions were allowed to remain in contact with the surface until a stable conductivity had reached equilibrium. Avidin-free buffer solutions were then injected to rinse off non-specifically bound analytes. Two solenoid valves were used to allow an automatic dispensing of the sample/buffer solution into microchannels. The limit of detection found for avidin-biotin system was 75 nmol L-1

    Contactless conductivity detection: a new tool for monitoring biomolecular interactions on analytical microsystems

    No full text
    O trabalho descrito nesta tese mostra a aplicação de um sistema de detecção condutométrica sem contato acoplado capacitivamente (C4D) para monitorar interações biomoleculares em microssistemas analíticos. Inicialmente, o desempenho analítico de microssistemas fabricados em vidro, poli(dimetilsiloxano) (PDMS) e poliéster-toner (PT) foi avaliado de modo a escolher o melhor material (em termos de facilidades de fabricação, custo e repetibilidade) para os ensaios biomoleculares. Dentre os materiais estudados, os dispositivos fabricados em PT mostraram-se mais adequados para testes rápidos, onde a repetibilidade analítica não é o parâmetro mais importante. Os dispositivos fabricados em PDMS e selados contra uma placa de vidro apresentaram os melhores resultados em termos de repetibilidade e o desempenho analítico foi similar aos dispositivos de vidro. Dessa maneira, os dispositivos fabricados em PDMS/vidro foram escolhidos para a demonstração dos objetivos da tese. Por outro lado, os dispositivos fabricados em PT foram explorados para estudar a configuração geométrica do sistema de C4D. A instrumentação para monitoramento dos ensaios de ligação foi composta basicamente de dois sistemas de C4D, um software escrito em LabVIEW e um sistema de bombeamento das soluções. De modo a encontrar a configuração ideal da cela de detecção, geometrias contendo três, quatro e cinco eletrodos foram avaliadas em dispositivos de PT. A configuração ótima foi composta de três eletrodos, espaçados simetricamente. Nesta geometria, um eletrodo é utilizado para aplicar o sinal senoidal de excitação e os outros dois são utilizados para capturar o sinal resultante. As dimensões dos eletrodos (largura e espaçamento entre eles) foram otimizados usando ferramentas quimométricas. O complexo avidina-biotina foi utilizado como modelo de ligação para mostrar a aplicabilidade do sistema proposto. Para os microssistemas biomoleculares, os eletrodos (com geometria otimizada) foram fabricados sobre a superfície de uma placa de vidro por fotolitografia, sputtering e lift-off. Os eletrodos de detecção foram isolados com uma camada de óxido de silício com espessura de 50 nm, depositada pelo processo de deposição química em fase de vapor assistida por plasma. A camada de SiO2 foi modificada quimicamente com solução de 3-amino-propil-trietóxi-silano em etanol. Para imobilização covalente de biotina, uma alíquota de 10 ?L de fotobiotina dissolvida em água (0,1 mg/mL) foi adicionada à superfície e exposta a radiação ultravioleta (365 nm, 10 mW/cm2) durante 15 min. A detecção foi realizada aplicando um sinal senoidal, a partir de um gerador de funções, ao eletrodo de excitação registrando o sinal resultante nos dois eletrodos receptores. Para minimizar a captura de ruído elétrico, os experimentos foram realizados em uma gaiola de Faraday. O controle e a aquisição de dados foi feito mediante um software escrito em LabVIEW monitorando os sensorgramas de condutividade em tempo real. Os canais microfluídicos foram fabricados em PDMS por litografia suave e selados irrevesivelmente contra a placa de vidro contendo os eletrodos isolados e modificados quimicamente. As soluções (tampão e amostra) foram manuseadas com auxílio de uma bomba peristáltica ou duas bombas seringas. Soluções contendo tampão e avidina foram introduzidas nos microcanais e as mudanças de conductividade foram monitoradas em função do tempo. As soluções contendo avidina permaneceram em contato com a superfície modificada até o sinal de condutividade atingir um patamar de equilíbrio. Depois disso, solução tampão foi introduzida no microcanal para remover os analitos adsorvidos à superfície. Duas válvulas solenóides foram utilizadas para permitir um controle automático da distribuição das soluções nos microcanais. O limite de detecção obtido para a interação entre avidina e biotina foi de 75 nmol L-1.The study reported in this thesis shows the application of a capacitively coupled contactless conductivity detection (C4D) for monitoring biomolecular interactions on analytical microsystems. Initially, the analytical performance of the microsystems fabricated in glass, poly(dimethylsiloxane) (PDMS) and polyester-toner (PT) was investigated in order to choose the best material (in terms of fabrication facilities, costs and repeatability) for the biomolecular assays. Among all substrate materials studied, devices fabricated in PT showed suitability for quick experiments, in which the analytical repeatability is not the most important parameter. The devices fabricated in PDMS and sealed against a glass plate presented the best results in terms of repeatability and the analytical performance was similar to that one of glass devices. For this reason, PDMS/glass devices were chosen for showing the goals of this thesis. On the other hand, PT devices were employed to study the geometrical design of the C4D system. The instrumentation for monitoring binding assays was basically composed of two C4D systems, a software written in LabVIEW and a solution pumping system. In order to find the suitable detection cell configuration for this dual-C4D system, designs containing three, four and five electrodes were evaluated on PT devices. The optimal design was composed of three electrodes symmetrically spaced. In this configuration, one electrode is used for applying an excitation sinusoidal wave and the other two for picking up the resulting signal. The dimensions of the electrodes (width and gap) were optimized by chemometric tools. The avidin-biotin complex was used as a binding model for showing the feasibility of the proposed system. For the biomolecular microsystems, electrodes were fabricated on glass surface using photolithographic, sputtering and lift-off processes. Detection electrodes were insulated with a 50-nm silicon oxide layer deposited by plasmaenhanced chemical vapor deposition. The SiO2 layer was functionalized by immersing the cleaned surface in a 3-aminopropyltriethoxy-silane solution in ethanol for 3 h. For biotinylation of the amino-silane layer, 10 ?L of photobiotin dissolved in deionized water (0.1 mg/mL) was dropped on the modified glass surface and exposed to a 365 nm UV radiation at intensity of 10 mW/cm2 for 15 min. Detection was carried out by passing a sinusoidal excitation signal from the function signal generator to the first electrode and picking up the resulting signal at the two receiver electrodes. To reduce electrical noise pickup, all measurements were carried out in a Faraday cage. The data acquisition was obtained in a software written in LabVIEW and the conductivity sensorgrams were recorded in real-time. The microfluidic network was fabricated in PDMS by soft lithography and irreversibly sealed against the electrodes plate. Solutions were handled into microfluidic channels using a peristaltic pump or two syringe pumps. Buffer and avidin-containing solution was injected into the microchannels and conductivity changes were monitored over time. Avidin solutions were allowed to remain in contact with the surface until a stable conductivity had reached equilibrium. Avidin-free buffer solutions were then injected to rinse off non-specifically bound analytes. Two solenoid valves were used to allow an automatic dispensing of the sample/buffer solution into microchannels. The limit of detection found for avidin-biotin system was 75 nmol L-1

    Comparison of the analytical performance of electrophoresis microchannels fabricated in PDMS, glass, and polyester-toner

    No full text
    This paper compares the analytical performance of microchannels fabricated in PDMS, glass, and polyester-toner for electrophoretic separations. Glass and PDMS chips were fabricated using well-established photolithographic and replica-molding procedures, respectively. PDMS channels were sealed against three different types of materials: native PDMS, plasma-oxidized PDMS, and glass. Polyester-toner chips were micromachined by a direct-printing process using an office laser printer. All microchannels were fabricated with similar dimensions according to the limitations of the direct-printing process (width/depth 150 mu m/12 mu m). LIF was employed for detection to rule out any losses in separation efficiency due to the detector configuration. Two fluorescent dyes, coumarin and fluorescein, were used as model analytes. Devices were evaluated for the following parameters related to electrophoretic separations: EOF, heat dissipation, injection reproducibility, separation efficiency, and adsorption to channel wall.Coordenadoria de Aperfeicoamento de Pessoal de Ensino Superior (CAPES)[BEX0706/02-1]Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)National Institutes of Health (NIH)[NS049229]National Institutes of Health (NIH)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)[04/01525-0]Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Conselho Nacional de Desenvolvimento Cientifico Tecnologico (CNPq)[478467/2006-0

    Fabrication and integration of planar electrodes for contactless conductivity detection on polyester-toner electrophoresis microchips

    No full text
    In this report, we describe the microfabrication and integration of planar electrodes for contactless conductivity detection on polyester‐toner (PT) electrophoresis microchips using toner masks. Planar electrodes were fabricated by three simple steps: (i) drawing and laser‐printing the electrode geometry on polyester films, (ii) sputtering deposition onto substrates, and (iii) removal of toner layer by a lift‐off process. The polyester film with anchored electrodes was integrated to PT electrophoresis microchannels by lamination at 120°C in less than 1 min. The electrodes were designed in an antiparallel configuration with 750 μm width and 750 μm gap between them. The best results were recorded with a frequency of 400 kHz and 10 Vpp using a sinusoidal wave. The analytical performance of the proposed microchip was evaluated by electrophoretic separation of potassium, sodium and lithium in 150 µm wide×6 µm deep microchannels. Under an electric field of 250 V/cm the analytes were successfully separated in less than 90 s with efficiencies ranging from 7000 to 13 000 plates. The detection limits (S/N = 3) found for K+, Na+, and Li+ were 3.1, 4.3, and 7.2 μmol/L, respectively. Besides the low‐cost and instrumental simplicity, the integrated PT chip eliminates the problem of manual alignment and gluing of the electrodes, permitting more robustness and better reproducibility, therefore, more suitable for mass production of electrophoresis microchips29112260226

    Rapid prototyping of polymeric electrophoresis microchips with integrated copper electrodes for contactless conductivity detection

    No full text
    A simple and easy approach to produce polymeric microchips with integrated copper electrodes for capacitively coupled contactless conductivity detection (C4D) is described. Copper electrodes were fabricated using a printed circuit board (PCB) as an inexpensive thin-layer of metal. The electrode layout was first drawn and laser printed on a wax paper sheet. The toner layer deposited on the paper sheet was thermally transferred to the PCB surface working as a mask for wet chemical etching of the copper layer. After the etching step, the toner was removed with an acetonitrile-dampened cotton. A poly(ethylene terephthalate) (PET) film coated with a thin thermo-sensitive adhesive layer was used to laminate the PCB plate providing an insulator layer of the electrodes to perform C4D measurements. Electrophoresis microchannels were fabricated in poly(dimethylsiloxane) (PDMS) by soft lithography and reversibly sealed against the PET film. These hybrid PDMS/PET chips exhibited a stable electroosmotic mobility of 4.25 ± 0.04 × 10−4 V cm−2 s−1, at pH 6.1, over fifty runs. Efficiencies ranging from 1127 to 1690 theoretical plates were obtained for inorganic cations31168172CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESPSem informaçãoSem informaçã

    Rapid prototyping of polymeric electrophoresis microchips with integrated copper electrodes for contactless conductivity detection

    No full text
    A simple and easy approach to produce polymeric microchips with integrated copper electrodes for capacitively coupled contactless conductivity detection (CD) is described. Copper electrodes were fabricated using a printed circuit board (PCB) as an inexpensive thin-layer of metal. The electrode layout was first drawn and laser printed on a wax paper sheet. The toner layer deposited on the paper sheet was thermally transferred to the PCB surface working as a mask for wet chemical etching of the copper layer. After the etching step, the toner was removed with an acetonitrile-dampened cotton. A poly(ethylene terephthalate) (PET) film coated with a thin thermo-sensitive adhesive layer was used to laminate the PCB plate providing an insulator layer of the electrodes to perform CID measurements. Electrophoresis microchannels were fabricated in poly(dimethylsiloxane) (PDMS) by soft lithography and reversibly sealed against the PET film. These hybrid PDMS/PET chips exhibited a stable electroosmotic mobility of 4.25 +/- 0.04 x 10(-4) V cm(-2) s(-1), at pH 6.1, over fifty runs. Efficiencies ranging from 1127 to 1690 theoretical plates were obtained for inorganic cations.CNPqFAPES
    corecore