147 research outputs found

    Assessment of “silent” restenosis and long-term follow-up after successful angioplasty in single vessel coronary artery disease: The value of quantitative exercise electrocardiography and quantitative coronary angiography

    Get PDF
    AbstractExercise electrocardiographic (ECG) testing during follow-up after coronary angioplasty is widely applied to evaluate the efficacy of angioplasty, even in asymptomatic patients. One hundred forty-one asymptomatic patients without previous myocardial infarction underwent quantitative exercise ECG testing and quantitative coronary angiography 1 to 6 months after successful angioplasty in single vessel coronary artery disease to 1) determine the value of exercise ECG testing to detect “silent” restenosis, and 2) assess the long-term prognostic value of exercise ECG testing and coronary angiography.The prevalence of restenosis (defined as ≄50% luminal narrowing at the dilation site) was 12% in this selected study group. Of 26 patients with an abnormal exercise ECG (ST segment depression ≄0.1 mV), only 4 (15%) showed recurrence of stenosis. Sensitivity and specificity for detection of restenosis were 24% and 82%, respectively.One hundred thirty-four patients (95%) were followed up 1 to 64 months (mean 35) after exercise ECG testing and coronary angiography. Thirty-two patients (24%) experienced a cardiac event: in 25 patients (78%) the initial event was recurrent angina pectoris (New York Heart Association class III or IV) and in 7 patients (22%) it was myocardial infarction, although cardiac death did not occur. The mean interval between exercise ECG testing and the initial cardiac events was 14 months (range 1 to 55), whereas 47% of the initial events took place ≀6 months after exercise ECG testing. An abnormal exercise test result and angiographic restenosis had, respectively, a predictive value of 36% and 41% and a relative risk of 1.7 and 1.9. Gender, age and extent of ST segment depression were not related to the occurrence of cardiac events.Thus, exercise ECG testing is not the technique of choice to detect silent restenosis after coronary angioplasty of single vessel coronary artery disease. An abnormal exercise test result and angiographic evidence of restenosis had only limited value in predicting long-term outcome in this patient group

    Long-term clinical outcomes of everolimus-eluting bioresorbable scaffolds versus everolimus-eluting stents:final five-year results of the AIDA randomised clinical trial

    Get PDF
    Background: Absorb bioresorbable vascular scaffold (BVS)-related events have been reported between 1 and 3 years – the period of active scaffold bioresorption. Data on the performance of the Absorb BVS in daily clinical practice beyond this time point are scarce. Aims: This report aimed to provide the final five-year clinical follow-up of the Absorb BVS in comparison with the XIENCE everolimus-eluting stent (EES). In addition, we evaluated the effect of prolonged dual antiplatelet therapy (DAPT) administration on events in the scaffold group. Methods: AIDA was a multicentre, investigator-initiated, non-inferiority trial, in which 1,845 unselected patients with coronary artery disease were randomly assigned to either the Absorb BVS (n=924) or the XIENCE EES (n=921). Target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction or target vessel revascularisation, was the primary endpoint. Scaffold thrombosis cases were matched with controls and tested for the effect of prolonged DAPT. Results: Up to five-year follow-up, there was no difference in TVF between the Absorb BVS (17.7%) and the XIENCE EES (16.1%) (hazard ratio [HR] 1.31, 95% confidence interval [CI]: 0.90-1.41; p=0.302). Definite or probable device thrombosis (DT) occurred in 43 patients (4.8%) in the scaffold group compared to 13 patients (1.5%) in the stent group (HR 3.32, 95% CI: 1.78-6.17; p<0.001). DT between 3 and 4 years occurred six times in the Absorb arm versus three times in the XIENCE arm. Between 4 and 5 years, the incidence was three versus two, respectively. Of those three DT in the scaffold group, two occurred in XIENCE EES-treated lesions. The odds ratio of scaffold thrombosis in patients on DAPT compared to off DAPT throughout five-year follow-up was 0.36 (95% CI: 0.15-0.86). Conclusions: The excess risk of the Absorb BVS on late adverse events, in particular device thrombosis, in routine PCI continues up to 4 years and seems to plateau afterwards

    Effect of a nurse-coordinated prevention programme on cardiovascular risk after an acute coronary syndrome: main results of the RESPONSE randomised trial

    Get PDF
    Objective To quantify the impact of a practical, hospital-based nurse-coordinated prevention programme on cardiovascular risk, integrated into the routine clinical care of patients discharged after an acute coronary syndrome, as compared with usual care only. Design RESPONSE (Randomised Evaluation of Secondary Prevention by Outpatient Nurse SpEcialists) was a randomised clinical trial. Setting Multicentre trial in secondary and tertiary healthcare settings. Participants 754 patients admitted for acute coronary syndrome. Intervention A nurse-coordinated prevention programme, consisting of four outpatient nurse clinic visits, focusing on healthy lifestyles, biometric risk factors and medication adherence, in addition to usual care. Main outcome measures The main outcome was 10-year cardiovascular mortality risk as estimated by Systematic Coronary Risk Evaluation at 12 months follow-up. Secondary outcomes included Framingham Coronary Risk Score at 12 months, in addition to changes in individual risk factors. Risk factor control was classified as ‘poor’ if 0 to 3 factors were on target, ‘fair’ if 4 to 6 factors were on target, and ‘good’ if 7 to 9 were on target. Results The mean Systematic Coronary Risk Evaluation at 12 months was 4.4 per cent (SD 4.5) in the intervention group and 5.4 per cent (SD 6.2) in the control group (p=0.021), representing a 17.4% relative risk reduction. At 12 months, risk factor control classified as ‘good’ was achieved in 35% of patients in the intervention group compared with 25% in the control group (p=0.003). Attendance to the nurse-coordinated prevention programme was 92%. In the intervention group, 86 rehospitalisations were observed against 132 in the control group (relative risk reduction 34.8%, p=0.023). Conclusions The nurse-coordinated hospital-based prevention programme in addition to usual care is a practical, yet effective method for reduction of cardiovascular risk in patients with coronary disease. Our data suggest that the counselling component of the programme may lead to a reduction in hospital readmissions

    A controlled trial of rivaroxaban after transcatheter aortic-valve replacement

    Get PDF
    Background: whether the direct factor Xa inhibitor rivaroxaban can prevent thromboembolic events after transcatheter aortic-valve replacement (TAVR) is unclear. Methods: we randomly assigned 1644 patients without an established indication for oral anticoagulation after successful TAVR to receive rivaroxaban at a dose of 10 mg daily (with aspirin at a dose of 75 to 100 mg daily for the first 3 months) (rivaroxaban group) or aspirin at a dose of 75 to 100 mg daily (with clopidogrel at a dose of 75 mg daily for the first 3 months) (antiplatelet group). The primary efficacy outcome was the composite of death or thromboembolic events. The primary safety outcome was major, disabling, or life-threatening bleeding. The trial was terminated prematurely by the data and safety monitoring board because of safety concerns. Results: after a median of 17 months, death or a first thromboembolic event (intention-to-treat analysis) had occurred in 105 patients in the rivaroxaban group and in 78 patients in the antiplatelet group (incidence rates, 9.8 and 7.2 per 100 person-years, respectively; hazard ratio with rivaroxaban, 1.35; 95% confidence interval [CI], 1.01 to 1.81; P = 0.04). Major, disabling, or life-threatening bleeding (intention-to-treat analysis) had occurred in 46 and 31 patients, respectively (4.3 and 2.8 per 100 person-years; hazard ratio, 1.50; 95% CI, 0.95 to 2.37; P = 0.08). A total of 64 deaths occurred in the rivaroxaban group and 38 in the antiplatelet group (5.8 and 3.4 per 100 person-years, respectively; hazard ratio, 1.69; 95% CI, 1.13 to 2.53). Conclusions: in patients without an established indication for oral anticoagulation after successful TAVR, a treatment strategy including rivaroxaban at a dose of 10 mg daily was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than an antiplatelet-based strategy. (Funded by Bayer and Janssen Pharmaceuticals; GALILEO ClinicalTrials.gov number, NCT02556203.)

    Radiofrequency Ablation vs Endoscopic Surveillance for Patients With Barrett Esophagus and Low-Grade Dysplasia: A Randomized Clinical Trial

    Get PDF
    Importance Barrett esophagus containing low-grade dysplasia is associated with an increased risk of developing esophageal adenocarcinoma, a cancer with a rapidly increasing incidence in the western world.Objective To investigate whether endoscopic radiofrequency ablation could decrease the rate of neoplastic progression.Design, Setting, and Participants Multicenter randomized clinical trial that enrolled 136 patients with a confirmed diagnosis of Barrett esophagus containing low-grade dysplasia at 9 European sites between June 2007 and June 2011. Patient follow-up ended May 2013.Interventions Eligible patients were randomly assigned in a 1:1 ratio to either endoscopic treatment with radiofrequency ablation (ablation) or endoscopic surveillance (control). Ablation was performed with the balloon device for circumferential ablation of the esophagus or the focal device for targeted ablation, with a maximum of 5 sessions allowed.Main Outcomes and Measures The primary outcome was neoplastic progression to high-grade dysplasia or adenocarcinoma during a 3-year follow-up since randomization. Secondary outcomes were complete eradication of dysplasia and intestinal metaplasia and adverse events.Results Sixty-eight patients were randomized to receive ablation and 68 to receive control. Ablation reduced the risk of progression to high-grade dysplasia or adenocarcinoma by 25.0% (1.5% for ablation vs 26.5% for control; 95% CI, 14.1%-35.9%; P

    Subcutaneous or Transvenous Defibrillator Therapy.

    Get PDF
    BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.)
    • 

    corecore