38 research outputs found

    Assisting Novice Teachers With Promoting Democratic Education in the Social Studies Classroom

    Get PDF
    The purpose of this essay is to provide new social studies teachers with an array of effective and plausible strategies for infusing a democratic education into their classrooms. The presented lessons are grounded in the theories and ideals taught at the university level, but they have been constructed in a practical and realistic manner as such that the often-overwhelmed teacher who is removed from their academic backgrounds can achieve the oft-referenced aims of the field of education. In this sense, the article seeks to bridge the gap between the theories and practices of social studies education and, in doing so, better prepare novice teachers to succeed in their practice. As such, the essay and its contents seek to inform the practices of novice teachers and assist them in feeling both prepared and effective as educators of the social studies

    Assisting Novice Teachers With Promoting Democratic Education in the Social Studies Classroom

    Get PDF
    The purpose of this essay is to provide new social studies teachers with an array of effective and plausible strategies for infusing a democratic education into their classrooms. The presented lessons are grounded in the theories and ideals taught at the university level, but they have been constructed in a practical and realistic manner as such that the often-overwhelmed teacher who is removed from their academic backgrounds can achieve the oft-referenced aims of the field of education. In this sense, the article seeks to bridge the gap between the theories and practices of social studies education and, in doing so, better prepare novice teachers to succeed in their practice. As such, the essay and its contents seek to inform the practices of novice teachers and assist them in feeling both prepared and effective as educators of the social studies

    Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding

    Get PDF
    The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements

    Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding

    Get PDF
    The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements

    Magnetic Field Mapping and Correction for Moving OP-MEG

    Get PDF
    Background: Optically pumped magnetometers (OPMs) have made moving, wearable magnetoencephalography (MEG) possible. The OPMs typically used for MEG require a low background magnetic field to operate, which is achieved using both passive and active magnetic shielding. However, the background magnetic field is never truly zero Tesla, and so the field at each of the OPMs changes as the participant moves. This leads to position and orientation dependent changes in the measurements, which manifest as low frequency artefacts in MEG data. Objective: We model the spatial variation in the magnetic field and use the model to predict the movement artefact found in a dataset. Methods: We demonstrate a method for modelling this field with a triaxial magnetometer, then show that we can use the same technique to predict the movement artefact in a real OPM-based MEG (OP-MEG) dataset. Results: Using an 86-channel OP-MEG system, we found that this modelling method maximally reduced the power spectral density of the data by 27.8 ± 0.6 dB at 0 Hz, when applied over 5 s non-overlapping windows. Conclusion: The magnetic field inside our state-of-the art magnetically shielded room can be well described by low-order spherical harmonic functions. We achieved a large reduction in movement noise when we applied this model to OP-MEG data. Significance: Real-time implementation of this method could reduce passive shielding requirements for OP-MEG recording and allow the measurement of low-frequency brain activity during natural participant movement

    A lightweight magnetically shielded room with active shielding

    Get PDF
    Magnetically shielded rooms (MSRs) use multiple layers of materials such as MuMetal to screen external magnetic fields that would otherwise interfere with high precision magnetic field measurements such as magnetoencephalography (MEG). Optically pumped magnetometers (OPMs) have enabled the development of wearable MEG systems which have the potential to provide a motion tolerant functional brain imaging system with high spatiotemporal resolution. Despite significant promise, OPMs impose stringent magnetic shielding requirements, operating around a zero magnetic field resonance within a dynamic range of ± 5 nT. MSRs developed for OPM-MEG must therefore effectively shield external sources and provide a low remnant magnetic field inside the enclosure. Existing MSRs optimised for OPM-MEG are expensive, heavy, and difficult to site. Electromagnetic coils are used to further cancel the remnant field inside the MSR enabling participant movements during OPM-MEG, but present coil systems are challenging to engineer and occupy space in the MSR limiting participant movements and negatively impacting patient experience. Here we present a lightweight MSR design (30% reduction in weight and 40–60% reduction in external dimensions compared to a standard OPM-optimised MSR) which takes significant steps towards addressing these barriers. We also designed a ‘window coil’ active shielding system, featuring a series of simple rectangular coils placed directly onto the walls of the MSR. By mapping the remnant magnetic field inside the MSR, and the magnetic field produced by the coils, we can identify optimal coil currents and cancel the remnant magnetic field over the central cubic metre to just |B|= 670 ± 160 pT. These advances reduce the cost, installation time and siting restrictions of MSRs which will be essential for the widespread deployment of OPM-MEG

    Crowdsourcing hypothesis tests: Making transparent how design choices shape research results

    Get PDF
    To what extent are research results influenced by subjective decisions that scientists make as they design studies? Fifteen research teams independently designed studies to answer fiveoriginal research questions related to moral judgments, negotiations, and implicit cognition. Participants from two separate large samples (total N > 15,000) were then randomly assigned to complete one version of each study. Effect sizes varied dramatically across different sets of materials designed to test the same hypothesis: materials from different teams renderedstatistically significant effects in opposite directions for four out of five hypotheses, with the narrowest range in estimates being d = -0.37 to +0.26. Meta-analysis and a Bayesian perspective on the results revealed overall support for two hypotheses, and a lack of support for three hypotheses. Overall, practically none of the variability in effect sizes was attributable to the skill of the research team in designing materials, while considerable variability was attributable to the hypothesis being tested. In a forecasting survey, predictions of other scientists were significantly correlated with study results, both across and within hypotheses. Crowdsourced testing of research hypotheses helps reveal the true consistency of empirical support for a scientific claim.</div

    Distinctions and blurred boundaries between qualitative approaches and public and patient involvement (PPI) in research

    No full text
    Purpose: International health and social care policy increasingly draws on stakeholder experiences and opinions. The distinctions between various approaches to researching “insider” perspectives are contentious. This article explores features (e.g. philosophy, ethics, and power dynamics) of qualitative approaches and public and patient involvement (PPI) in communication disorder research and explicates the blurred boundaries between them. Method: We use two case studies involving PPI contributors with aphasia – an Irish mixed methodologies study and a Danish qualitative study - to illustrate PPI in research and thus demonstrate how researchers can bridge the gap between theoretical considerations and research implementation Result: There are important distinctions between PPI in research and qualitative approaches (e.g. origins, roles, and reimbursement) and many blurred boundaries (e.g. inclusion, openness to mutual learning and “insider” perspectives). A key difference is that PPI contributors take an active role at project level and more flexibility in roles is required in PPI research. These flexible and varied roles reflect the shared decision-making powers between lay and professional researchers. Conclusion: PPI can add innovation to qualitative and mixed methods communication disorder research as illustrated in both case studies. However, researchers wishing to include PPI must embrace and respond to the evolving and flexible nature of PPI relationships and processes. Flexibility, negotiation and continuous reflection on methodological approaches, power dynamics, roles and co-created knowledge will impact and transform the field of research in communication disorders. </p
    corecore