13 research outputs found

    At-wavelength characterization of the extreme ultraviolet Engineering Test Stand Set-2 optic

    Full text link
    At-wavelength interferometric characterization of a new 4x-reduction lithographic-quality extreme ultraviolet (EUV) optical system is described. This state-of-the-art projection optic was fabricated for installation in the EUV lithography Engineering Test Stand (ETS) and is referred to as the ETS Set-2 optic. EUV characterization of the Set-2 optic is performed using the EUV phase-shifting point diffraction interferometer (PS/PDI) installed on an undulator beamline at Lawrence Berkeley National Laboratory's Advanced Light Source. This is the same interferometer previously used for the at-wavelength characterization and alignment of the ETS Set-1 optic. In addition to the PS/PDI-based full-field wavefront characterization, we also present wavefront measurements performed with lateral shearing interferometry, the chromatic dependence of the wavefront error, and the system-level pupil-dependent spectral-bandpass characteristics of the optic; the latter two properties are only measurable using at-wavelength interferometry

    Intrathoracic plates versus extrathoracic plates: a comparison of postoperative pain in surgical stabilization of rib fracture technique

    No full text
    Background Surgical stabilization of rib fractures (SSRF) has been shown to improve outcomes, yet there is an absence of studies comparing SSRF techniques. An intrathoracic system that minimizes incision length has recently been developed and adopted by multiple institutions. We hypothesized that SSRF with an intrathoracic system plus intercostal nerve cryoneurolysis (IC) leads to improved pain control compared with an extrathoracic system plus IC.Methods A single-center, retrospective chart review was performed comparing intrathoracic SSRF versus extrathoracic SSRF, and included patients undergoing SSRF from 2015 to 2021 at a level 1 trauma center. Patients who did not undergo intercostal nerve cryoablation were excluded. The primary outcome was opioid consumption based on morphine milligram equivalent (MME) consumption. We collected Rib score, Blunt Pulmonary Contusion 18 Score, number of rib fractures, number of ribs plated, and Injury Severity Score (ISS) to compare baseline characteristics of each group.Results A total of 112 patients were evaluated for study inclusion. Thirty-one patients were excluded due to missing outcomes data and/or lack of cryoablation. There was no difference in ISS or Rib Score between the intrathoracic (n=33) and extrathoracic (n=48) groups. At 7-day follow-up, the median MME requirement was significantly lower in the intrathoracic group (21.25) versus the extrathoracic group (46.20) (p=0.02).Conclusion Intrathoracic SSRF was associated with a lower postoperative MME consumption compared with extrathoracic SSRF. These data support the use of intrathoracic SSRF to improve pain control compared to extrathoracic SSRF.Level of evidence III
    corecore