21,130 research outputs found

    Cascaded complementary pair broadband transistor amplifiers Patent

    Get PDF
    Broadband distribution amplifier with complementary pair transistor output stage

    Differential absorption and scattering sensitivity predictions

    Get PDF
    A set of general equations for evaluating the sensitivity of the Differential Absorption and Scattering (DAS) technique based upon a conventional analysis of statistical errors is derived. The equations are put in a proper form for evaluating total column density and range resolved concentration measurements of a variety of atmospheric species. The derived equation are subsequently used to analyze the sensitivity of DAS in three specific applications assuming realistic parameters for the optical and electronic components of proposed DAS systems. The three DAS applications evaluated are: (1) measurement of nitrogen at ground levels over a horizontal path; (2) measurement of atmospheric ozone depletion in the wake of a jet engine at 20 km altitude; and (3) measurements of the ozone distribution in the atmosphere from an orbiting space platform, in a downward viewing mode. The results of this study have shown that with reasonable laser energy and telescope receiver dimensions, DAS is capable of meeting requirements for performing these measurements

    Development and verification of global/local analysis techniques for laminated composites

    Get PDF
    A two-dimensional to three-dimensional global/local finite element approach was developed, verified, and applied to a laminated composite plate of finite width and length containing a central circular hole. The resulting stress fields for axial compression loads were examined for several symmetric stacking sequences and hole sizes. Verification was based on comparison of the displacements and the stress fields with those accepted trends from previous free edge investigations and a complete three-dimensional finite element solution of the plate. The laminates in the compression study included symmetric cross-ply, angle-ply and quasi-isotropic stacking sequences. The entire plate was selected as the global model and analyzed with two-dimensional finite elements. Displacements along a region identified as the global/local interface were applied in a kinematically consistent fashion to independent three-dimensional local models. Local areas of interest in the plate included a portion of the straight free edge near the hole, and the immediate area around the hole. Interlaminar stress results obtained from the global/local analyses compares well with previously reported trends, and some new conclusions about interlaminar stress fields in plates with different laminate orientations and hole sizes are presented for compressive loading. The effectiveness of the global/local procedure in reducing the computational effort required to solve these problems is clearly demonstrated through examination of the computer time required to formulate and solve the linear, static system of equations which result for the global and local analyses to those required for a complete three-dimensional formulation for a cross-ply laminate. Specific processors used during the analyses are described in general terms. The application of this global/local technique is not limited software system, and was developed and described in as general a manner as possible

    Aerobee 350, flight 17.03 GE - Instrumentation information and calibration data

    Get PDF
    Airborne instrumentation system on Aerobee 350 sounding rocke

    Construction and Software Design for a Microcomputer Controlled pH/Ion Titrator

    Get PDF
    The construction of an automated titration device is described. The major components include an Apple II+ Microcomputer and 8-bit parallel interface. Fisher Accumet, Model 520 Digital pH/lon Meter, Gilmont Micrometer Buret of 2.5 mL capacity, Sigma stepper motor, power supply and driver to operate the buret, and a constant temperature bath of ± 0.005 °C stability. The limitations of the system are 0.001 pH/0.1 mv for the pH/ion sensing system, and 0.125 μL per step for the buret. The system as described is designed to determine equilibrium constants for metal ion-amino acid complexes. By changing the software a variety of different pH and redox titration experiments may be performed. A computer program used to operate the stepper motor driven syringe buret and record the pH from a digital pH meter is described. The program uses both Apple BASIC and assembly language. This is a closed loop operation in which the data from the pH meter is used to control the amount of reagent delivered by the buret. The results are displayed graphically as the titration proceeds. The variance of the pH readings are calculated using an assembly language subroutine and the calculations are done with zero round-off error

    Regrets

    Get PDF

    In/Visible

    Get PDF
    My MFA thesis and supporting exhibition focus on challenging the United States’ photographic archive that often left out African-American people. The work, through the use of appropriation and alternative photographic processes, disrupts America’s historical visual archive and notions that surround the white gaze. Through the unsettling of this visual space, new speculative narratives can be created to help imagine new futures. This work is the beginning of a process of mourning histories I have never known and reclaiming a place for myself and my family in the American landscape that is free of racial trauma

    Introduction to Workshop on Emerging Issues in Mergers & Acquisitions and Tribute to Joseph Flom

    Get PDF

    Introduction to Workshop on Emerging Issues in Mergers & Acquisitions and Tribute to Joseph Flom

    Get PDF
    • …
    corecore