23 research outputs found

    Human aging and photopic contrast sensitivity for angular frequencies

    Get PDF
    O objetivo deste estudo foi investigar o efeito do envelhecimento na sensibilidade a frequências angulares com luminância fotópica (42,6cd/m²). Foram mensuradas curvas de sensibilidade ao contraste em oito adultos jovens (20-29 anos) e oito idosos (60-70 anos) por meio do método psicofísico da escolha forçada. Todos os participantes estavam livres de doenças oculares identificáveis e tinham acuidade visual normal. Os resultados mostraram que o grupo de idosos apresentou alteração significante na faixa de frequências baixas e altas. Concluiu-se que o envelhecimento parece afetar o processamento de frequências angulares baixas e altas em condições de luminância fotópica.The aim of this study was to investigate the effect of aging on the sensitivity to angular frequencies in photopic luminance (42.6cd/m²). Contrast sensitivity curves were measured in eight adults, from 20 to 29 years old and eight elder people, from 60 to 70 years old by means of the forced-choice method. All subjects were free from identifiable ocular disease and had normal visual acuity. The results showed significant decline of the sensitivity of the older adults group to high and low frequencies. It was concluded that aging might affect the processing of high and low angular frequencies in photopic luminance conditions.CNP

    Envelhecimento Humano e Sensibilidade ao Contraste Fotópica para Frequências Angulares

    Get PDF
    The aim of this study was to investigate the effect of aging on the sensitivity to angular frequencies in photopic luminance (42.6cd/m2). Contrast sensitivity curves were measured in eight adults, from 20 to 29 years old and eight elder people, from 60 to 70 years old by means of the forced-choice method. All subjects were free from identifiable ocular disease and had normal visual acuity. The results showed significant decline of the sensitivity of the older adults group to high and low frequencies. It was concluded that aging might affect the processing of high and low angular frequencies in photopic luminance conditions.O objetivo deste estudo foi investigar o efeito do envelhecimento na sensibilidade a frequências angulares com luminância fotópica (42,6cd/m2). Foram mensuradas curvas de sensibilidade ao contraste em oito adultos jovens (20-29 anos) e oito idosos (60-70 anos) por meio do método psicofísico da escolha forçada. Todos os participantes estavam livres de doenças oculares identificáveis e tinham acuidade visual normal. Os resultados mostraram que o grupo de idosos apresentou alteração significante na faixa de frequências baixas e altas. Concluiu-se que o envelhecimento parece afetar o processamento de frequências angulares baixas e altas em condições de luminância fotópica

    Not informed by the author

    No full text
    A Estimulação Transcraniana por Corrente Contínua (ETCC) é um método para modulação não-invasiva da atividade cerebral que vem sendo amplamente utilizado na pesquisa clínica e na investigação da relação complexa entre comportamento e atividade cerebral. Por outro lado, os efeitos da ETCC sobre o desempenho visual ainda foram pouco estudados, e a especificidade de vias visuais e funções afetadas pela estimulação não foi investigada. É fundamental elucidar tais questões antes de propor aplicações clínicas adequadas da ETCC na reabilitação visual. Aqui, utilizamos testes psicofísicos e eletrofisiológicos sensíveis a alterações em diferentes vias e grupos de células do sistema visual para avaliar os efeitos da ETCC. Realizamos experimentos em voluntários saudáveis e um modelo animal. Nos experimentos em humanos, os participantes receberam ETCC anódica, catódica e placebo (Oz-Cz, 0,06mA/cm2) em sessões distintas. (1) Para testar a visão de cores, utilizamos Cambridge Colour Test (CCT) e uma tarefa de contraste de cores com grade senoidal verde-vermelho. No CCT a ETCC anódica aumentou a sensibilidade no eixo tritan (p<0,001) e não teve efeito sobre a sensibilidade nos eixos protan e deutan. ETCC catódica diminuiu a sensibilidade no eixo deutan e aumentou a sensibilidade no eixo tritan. Os efeitos retornaram à linha de base após 15 min. (2) Para testar visão de acromática utilizamos testes psicofísicos de sensibilidade ao contraste de grades e Pedestal--Pedestal. Utilizamos também Potencial Visual Evocado de Varredura (PVEv) para contraste e acuidade de Vernier. ETCC não afetou sensibilidade ao contraste psicofísica ou os limiares de Vernier ou contraste medidos com PVEv. ETCC anódica aumentou significativamente limiares para decremento do pedestal apenas nas respostas mediadas pela via magnocelular. Para o PVEv de contraste, ETCC catódica aumentou amplitude da resposta supralimiar para 0,5cpg e diminuiu para 4cpg sem afetar as respostas para 16cpg. ETCC catódica aumentou a fase para 4cpg e diminuiu para 16cpg. Houve efeito significativo da ETCC catódica e anódica sobre resposta supralimiar de Vernier. (3) Para avaliar os efeitos sobre o campo visual utilizamos os protocolos 10-2 e 60-4 do campímetro Humphrey. A ETCC só afetou significativamente o desempenho sobre os pontos mais excêntricos medidos com o campímetro, aumentando a sensibilidade. Ainda, resultados anteriores da literatura não foram replicados. O efeito diferencial da ETCC catódica sobre a sensibilidade tritan, deutan e o processamento de diferentes faixas de freqüência espacial sugere que diferentes vias e grupos de células no sistema visual são afetados de maneira distinta pela ETCC. Em geral, os resultados encontrados sugerem que ETCC pode ter um efeito distinto em diferentes grupos de células no córtex visual e assim, é uma ferramenta em potencial para estudar a organização do sistema visual. Além disso, as alterações de latência encontradas sugerem que a ETCC pode levar a alterações funcionais modulando a somação temporal das células 7 estimuladas. Futuros estudos devem levar em consideração possíveis efeitos diferenciais da ETCC em diferentes grupos de células nas áreas estimuladas. (4) No experimento realizado com modelo animal, coelhos albinos receberam ETCC sobre o córtex visual primário. PVE por flashes foram medidos antes e após ETCC. Apenas a ETCC catódica produziu efeitos significativos. Os resultados estão de acordo com a literatura em humanos e foram consistentes para todos os animais. O uso deste modelo possibilitará pesquisas no nível celular e molecular dos efeitos da ETCC sobre o córtex visualTranscranial Direct Current Stimulation ( tDCS ) is a noninvasive brain stimulation method that has been widely used in clinical research and investigations of the complex relationship between behavior and brain activity. Nevertheless, the effects of tDCS on visual performance are still poorly understood and specificity of the visual pathways and functions affected by stimulation was not yet investigated. It is essential to elucidate such issues before proposing appropriate clinical applications of tDCS on visual rehabilitation . Here, we used psychophysical and electrophysiological methods sensitive to changes in different groups of cells and pathways of the visual system to evaluate the effects of tDCS . We conducted experiments in healthy volunteers and an animal model . In human experiments , participants received anodal , cathodal and sham tDCS ( Oz - Cz , 0.06 mA/cm2 ) in separate sessions. (1) To test color vision , we used Cambridge Colour Test ( CCT ) and a color contrast sensitivity task with red-green sinusoidal gratings. Anodal tDCS increased sensitivity in the tritan axis ( p < 0.001 ) and had no effect on the sensitivity in protan and deutan axes . Cathodal tDCS decreased sensitivity in deutan axis and increased sensitivity in the tritan axis. The effects returned to baseline after 15 min. ( 2 ) To test achromatic vision we used psychophysical tests of grating contrast sensitivity and Pedestal - - Pedestal . We also used Sweep Visual Evoked Potential ( PVEv ) for contrast sensitivity and vernier acuity. TDCS did not affect psychophysical of PVEv contrast thresholds. Anodal tDCS significantly increased thresholds for the pedestal decrement only in the magnocellular pathway mediated responses. For PVEv contrast , cathodal tDCS increased to suprathreshold response amplitude to 0.5 cpd and decreased it for 4cpd without affecting responses to 16cpd . Cathodal tDCS increased the phase for 4cpg and decreased it to 16cpg . There was a significant effect of anodal and cathodal tDCS on suprathreshold Vernier responses. (3) To evaluate the effects on the visual field we used the 10-2 and 60-4 protocols of the Humphrey perimeter. tDCS only significantly affected the performance of the most eccentric points measured with the perimeter, increasing sensitivity. Still , previous literature results were not replicated. The opposite effect of cathodal tDCS on the tritan and deutan sensitivity, and in the processing of different spatial frequency bands suggests that different pathways and groups of cells in the visual system are affected differently by tDCS. In general , the results suggest that tDCS may have a different effect on different groups of cells in the visual cortex and thus is a potential tool for studying the organization of the visual system . Furthermore, the change latency encountered suggest that tDCS can lead to functional alterations of the temporal summation in the stimulated cells. Future studies should take into account possible differential effects of tDCS on different groups of cells in the stimulated areas. (4) In the experiment with the animal model, albino rabbits received tDCS over the primary visual cortex . VEP flashes were measured before and after tDCS. Only cathodal tDCS produced significant effects. The results are consistent with the literature in humans and were consistent for all animals . The use of this model will enable research of cellular and molecular mechanisms of tDCS on visual corte

    Not informed by the author

    No full text
    A Estimulação Transcraniana por Corrente Contínua (ETCC) é um método para modulação não-invasiva da atividade cerebral que vem sendo amplamente utilizado na pesquisa clínica e na investigação da relação complexa entre comportamento e atividade cerebral. Por outro lado, os efeitos da ETCC sobre o desempenho visual ainda foram pouco estudados, e a especificidade de vias visuais e funções afetadas pela estimulação não foi investigada. É fundamental elucidar tais questões antes de propor aplicações clínicas adequadas da ETCC na reabilitação visual. Aqui, utilizamos testes psicofísicos e eletrofisiológicos sensíveis a alterações em diferentes vias e grupos de células do sistema visual para avaliar os efeitos da ETCC. Realizamos experimentos em voluntários saudáveis e um modelo animal. Nos experimentos em humanos, os participantes receberam ETCC anódica, catódica e placebo (Oz-Cz, 0,06mA/cm2) em sessões distintas. (1) Para testar a visão de cores, utilizamos Cambridge Colour Test (CCT) e uma tarefa de contraste de cores com grade senoidal verde-vermelho. No CCT a ETCC anódica aumentou a sensibilidade no eixo tritan (p<0,001) e não teve efeito sobre a sensibilidade nos eixos protan e deutan. ETCC catódica diminuiu a sensibilidade no eixo deutan e aumentou a sensibilidade no eixo tritan. Os efeitos retornaram à linha de base após 15 min. (2) Para testar visão de acromática utilizamos testes psicofísicos de sensibilidade ao contraste de grades e Pedestal--Pedestal. Utilizamos também Potencial Visual Evocado de Varredura (PVEv) para contraste e acuidade de Vernier. ETCC não afetou sensibilidade ao contraste psicofísica ou os limiares de Vernier ou contraste medidos com PVEv. ETCC anódica aumentou significativamente limiares para decremento do pedestal apenas nas respostas mediadas pela via magnocelular. Para o PVEv de contraste, ETCC catódica aumentou amplitude da resposta supralimiar para 0,5cpg e diminuiu para 4cpg sem afetar as respostas para 16cpg. ETCC catódica aumentou a fase para 4cpg e diminuiu para 16cpg. Houve efeito significativo da ETCC catódica e anódica sobre resposta supralimiar de Vernier. (3) Para avaliar os efeitos sobre o campo visual utilizamos os protocolos 10-2 e 60-4 do campímetro Humphrey. A ETCC só afetou significativamente o desempenho sobre os pontos mais excêntricos medidos com o campímetro, aumentando a sensibilidade. Ainda, resultados anteriores da literatura não foram replicados. O efeito diferencial da ETCC catódica sobre a sensibilidade tritan, deutan e o processamento de diferentes faixas de freqüência espacial sugere que diferentes vias e grupos de células no sistema visual são afetados de maneira distinta pela ETCC. Em geral, os resultados encontrados sugerem que ETCC pode ter um efeito distinto em diferentes grupos de células no córtex visual e assim, é uma ferramenta em potencial para estudar a organização do sistema visual. Além disso, as alterações de latência encontradas sugerem que a ETCC pode levar a alterações funcionais modulando a somação temporal das células 7 estimuladas. Futuros estudos devem levar em consideração possíveis efeitos diferenciais da ETCC em diferentes grupos de células nas áreas estimuladas. (4) No experimento realizado com modelo animal, coelhos albinos receberam ETCC sobre o córtex visual primário. PVE por flashes foram medidos antes e após ETCC. Apenas a ETCC catódica produziu efeitos significativos. Os resultados estão de acordo com a literatura em humanos e foram consistentes para todos os animais. O uso deste modelo possibilitará pesquisas no nível celular e molecular dos efeitos da ETCC sobre o córtex visualTranscranial Direct Current Stimulation ( tDCS ) is a noninvasive brain stimulation method that has been widely used in clinical research and investigations of the complex relationship between behavior and brain activity. Nevertheless, the effects of tDCS on visual performance are still poorly understood and specificity of the visual pathways and functions affected by stimulation was not yet investigated. It is essential to elucidate such issues before proposing appropriate clinical applications of tDCS on visual rehabilitation . Here, we used psychophysical and electrophysiological methods sensitive to changes in different groups of cells and pathways of the visual system to evaluate the effects of tDCS . We conducted experiments in healthy volunteers and an animal model . In human experiments , participants received anodal , cathodal and sham tDCS ( Oz - Cz , 0.06 mA/cm2 ) in separate sessions. (1) To test color vision , we used Cambridge Colour Test ( CCT ) and a color contrast sensitivity task with red-green sinusoidal gratings. Anodal tDCS increased sensitivity in the tritan axis ( p < 0.001 ) and had no effect on the sensitivity in protan and deutan axes . Cathodal tDCS decreased sensitivity in deutan axis and increased sensitivity in the tritan axis. The effects returned to baseline after 15 min. ( 2 ) To test achromatic vision we used psychophysical tests of grating contrast sensitivity and Pedestal - - Pedestal . We also used Sweep Visual Evoked Potential ( PVEv ) for contrast sensitivity and vernier acuity. TDCS did not affect psychophysical of PVEv contrast thresholds. Anodal tDCS significantly increased thresholds for the pedestal decrement only in the magnocellular pathway mediated responses. For PVEv contrast , cathodal tDCS increased to suprathreshold response amplitude to 0.5 cpd and decreased it for 4cpd without affecting responses to 16cpd . Cathodal tDCS increased the phase for 4cpg and decreased it to 16cpg . There was a significant effect of anodal and cathodal tDCS on suprathreshold Vernier responses. (3) To evaluate the effects on the visual field we used the 10-2 and 60-4 protocols of the Humphrey perimeter. tDCS only significantly affected the performance of the most eccentric points measured with the perimeter, increasing sensitivity. Still , previous literature results were not replicated. The opposite effect of cathodal tDCS on the tritan and deutan sensitivity, and in the processing of different spatial frequency bands suggests that different pathways and groups of cells in the visual system are affected differently by tDCS. In general , the results suggest that tDCS may have a different effect on different groups of cells in the visual cortex and thus is a potential tool for studying the organization of the visual system . Furthermore, the change latency encountered suggest that tDCS can lead to functional alterations of the temporal summation in the stimulated cells. Future studies should take into account possible differential effects of tDCS on different groups of cells in the stimulated areas. (4) In the experiment with the animal model, albino rabbits received tDCS over the primary visual cortex . VEP flashes were measured before and after tDCS. Only cathodal tDCS produced significant effects. The results are consistent with the literature in humans and were consistent for all animals . The use of this model will enable research of cellular and molecular mechanisms of tDCS on visual corte

    Visual repercussions of occupational exposure to a mixture of solvents: Chromatic and achromatic vision in brazilian gas station workers

    No full text
    Objetivo: Avaliar repercussões da exposição ocupacional a uma mistura de solventes orgânicos sobre o desempenho visual de um grupo de frentistas. Método: Foram aplicados testes de ordenamento e discriminação de matizes, campo visual e sensibilidade ao contraste espacial de luminância em 25 frentistas (20 homens, M=36,4 anos, DP=8,9) e 25 controles sem histórico de exposição crônica a solventes (10 homens, M=33,8 anos, DP=8,8). As concentrações metabólitos urinários de tolueno (M=0,3 g/g de creatinina; DP=0,16) e xileno (M=0,1 g/g de creatinina; DP=0,02) e o tempo de trabalho (M=9,6 anos; DP=6,2) foram utilizados como indicativos da exposição dos frentistas. Os participantes foram submetidos a exame oftalmológico, e quando necessário, corrigir a acuidade visual para 20/20. Todas as medidas foram realizadas monocularmente com um olho escolhido ao acaso, com exceção do Potencial Visual Evocado Multifocal (PVEmf) e da campimetria. Para avaliar a visão de cores, utilizamos o Lanthony D15-d e Cambridge Colour Test 2.0. Na campimetria estática automatizada foi utilizado o protocolo branco-branco 24-2 do aparelho Humphrey Field Analyzer II-750i. A atividade elétrica visual cortical foi avaliada com o sistema de PVEmf Veris Science 5.2.4, utilizando um estímulo de 60 setores. A sensibilidade ao contraste espacial de luminância foi avaliada no teste Metropsis, para grades senoidais em 7 frequências espaciais de 0,2 a 20,0 cpg. Resultados: Os escores do grupo de frentistas e do grupo controle foram comparados pelo teste Mann-Whitney U. No teste de discriminação de cores (CCT), houve diferença estatística significativa entre controles e frentistas para a área total da elipse (p<0,01), elipticidade (p<0,05) e limiares nos eixos protan, deutan e tritan (p<0,05). No D15d houve diferença significativa entre os 8 dois grupos (p<0,01). Os dados da campimetria apresentaram diferenças significativas entre os dois grupos para as excentricidades de 90, 150 e 210, além dos valores de MD e PSD (p<0,05). Dos três frentistas avaliados com o PVEmf, todos apresentaram uma diminuição significativa (p<0,05) da amplitude do sinal (em relação a dados normativos) em um mínimo de 30 setores do campo visual, resultado que não foi observado no grupo controle. Nos testes de visão de cores, foi encontrada uma correlação (Spearman) positiva e significativa entre o tempo de trabalho e os índices do Lanthony D15d (p=0,52; p<0,05) e os limiares no eixo deutan (p=0,59; p<0,05). Na campimetria, houve correlações negativas significativas com o tempo de trabalho para a área da Fóvea (p=-051; p<0,05), e para os anéis de 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). Não foi encontrada correlação significativa entre a sensibilidade ao contraste e o tempo de trabalho. Conclusões: Os resultados mostram alterações amplas e difusas no processamento visual em decorrência da exposição crônica a solventes orgânicosPurpose: To evaluate the outcome of chronic occupational exposure to a mixture of solvents on the visual system of a group of gas station workers. Methods: 25 gas station workers (20 male; M=36,4 years old, SD=8,9) and 25 controls (10 male; M=33,8 years old, DP=8,8) with no history of chronic exposure to solvents were tested for hue discrimination and arrangement, spatial contrast sensitivity, visual field and multifocal VEPs. Urinary concentrations of toluene (M=0,3g/g of creatinine; Sd=0,16) and xylene metabolites (M=0,1 g/g creatinine; SD=0), along with the time of work (M=9,6 years; SD=6,2) were used as indicators of the exposure. The participants were submitted to an ophthalmologic examination and corrected the visual acuity to 20/20 whenever needed. All measurements were monocular (eye randomly chosen) and only one eye was tested, except for Multifocal Visual Evoked Potential (mfVEP) and the automated perimetry. Color was evaluated with the Lanthony D15d and Cambridge Colour Test 2.0. Automatic static perimetry used the white-on-white 24-2 protocol of the Humphrey Field Analyzer II-750i. Visual field was also evaluated with the mfVEP system Veris Science 5.2.4. Contrast sensitivity was measured with Metropsis software, using sine wave gratings of 0,2; 0,5; 1,0; 2,0; 5,0; 10,0 and 20,0 cpd. Results: The results for the two groups were compared using the Mann-Whitney U test. In the color discrimination test, the groups were significantly different for the thresholds in the three confusion axis tested (p<0,05), area of the ellipse (p<0,01) and ellipticity (p<0,05). In the color arrangement test, the two groups were significantly different (p<0,01). The automated perimetry results were also significantly different between groups for the 90, 150 e 210 eccentricity rings (p<0,05) and the MD and PSD values (p<0,05). Only three of the workers were tested with the mfVEP so far. All three had at least 30 sectors in the visual field 10 with significant loss of amplitude in the response (p<0,05, when compared to normative data). This result was not observed in the control group. The Spearman correlation coefficient was used to look for significant correlations between time of work and visual performance. For color vision, we found significant positive correlation between time of work and indexes of the Lanthony D15d (p=0,52; p<0,05) and deutan axis thresholds (p=0,59; p<0,05) for the CCT test. The analysis of sensitivity in eccentricity rings of perimetry data showed significant negative correlation with the time of work for the Fovea (p=-051; p<0,05) and rings of 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). The contrast sensitivity data was not significantly correlated with time of work. Conclusions: The results presented here suggest that chronic occupational exposure to organic solvents leads to changes in the visual system function even when the exposure is within occupational safety limits. The results also suggest that the visual changes are extensive and diffus

    Visual repercussions of occupational exposure to a mixture of solvents: Chromatic and achromatic vision in brazilian gas station workers

    Get PDF
    Objetivo: Avaliar repercussões da exposição ocupacional a uma mistura de solventes orgânicos sobre o desempenho visual de um grupo de frentistas. Método: Foram aplicados testes de ordenamento e discriminação de matizes, campo visual e sensibilidade ao contraste espacial de luminância em 25 frentistas (20 homens, M=36,4 anos, DP=8,9) e 25 controles sem histórico de exposição crônica a solventes (10 homens, M=33,8 anos, DP=8,8). As concentrações metabólitos urinários de tolueno (M=0,3 g/g de creatinina; DP=0,16) e xileno (M=0,1 g/g de creatinina; DP=0,02) e o tempo de trabalho (M=9,6 anos; DP=6,2) foram utilizados como indicativos da exposição dos frentistas. Os participantes foram submetidos a exame oftalmológico, e quando necessário, corrigir a acuidade visual para 20/20. Todas as medidas foram realizadas monocularmente com um olho escolhido ao acaso, com exceção do Potencial Visual Evocado Multifocal (PVEmf) e da campimetria. Para avaliar a visão de cores, utilizamos o Lanthony D15-d e Cambridge Colour Test 2.0. Na campimetria estática automatizada foi utilizado o protocolo branco-branco 24-2 do aparelho Humphrey Field Analyzer II-750i. A atividade elétrica visual cortical foi avaliada com o sistema de PVEmf Veris Science 5.2.4, utilizando um estímulo de 60 setores. A sensibilidade ao contraste espacial de luminância foi avaliada no teste Metropsis, para grades senoidais em 7 frequências espaciais de 0,2 a 20,0 cpg. Resultados: Os escores do grupo de frentistas e do grupo controle foram comparados pelo teste Mann-Whitney U. No teste de discriminação de cores (CCT), houve diferença estatística significativa entre controles e frentistas para a área total da elipse (p<0,01), elipticidade (p<0,05) e limiares nos eixos protan, deutan e tritan (p<0,05). No D15d houve diferença significativa entre os 8 dois grupos (p<0,01). Os dados da campimetria apresentaram diferenças significativas entre os dois grupos para as excentricidades de 90, 150 e 210, além dos valores de MD e PSD (p<0,05). Dos três frentistas avaliados com o PVEmf, todos apresentaram uma diminuição significativa (p<0,05) da amplitude do sinal (em relação a dados normativos) em um mínimo de 30 setores do campo visual, resultado que não foi observado no grupo controle. Nos testes de visão de cores, foi encontrada uma correlação (Spearman) positiva e significativa entre o tempo de trabalho e os índices do Lanthony D15d (p=0,52; p<0,05) e os limiares no eixo deutan (p=0,59; p<0,05). Na campimetria, houve correlações negativas significativas com o tempo de trabalho para a área da Fóvea (p=-051; p<0,05), e para os anéis de 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). Não foi encontrada correlação significativa entre a sensibilidade ao contraste e o tempo de trabalho. Conclusões: Os resultados mostram alterações amplas e difusas no processamento visual em decorrência da exposição crônica a solventes orgânicosPurpose: To evaluate the outcome of chronic occupational exposure to a mixture of solvents on the visual system of a group of gas station workers. Methods: 25 gas station workers (20 male; M=36,4 years old, SD=8,9) and 25 controls (10 male; M=33,8 years old, DP=8,8) with no history of chronic exposure to solvents were tested for hue discrimination and arrangement, spatial contrast sensitivity, visual field and multifocal VEPs. Urinary concentrations of toluene (M=0,3g/g of creatinine; Sd=0,16) and xylene metabolites (M=0,1 g/g creatinine; SD=0), along with the time of work (M=9,6 years; SD=6,2) were used as indicators of the exposure. The participants were submitted to an ophthalmologic examination and corrected the visual acuity to 20/20 whenever needed. All measurements were monocular (eye randomly chosen) and only one eye was tested, except for Multifocal Visual Evoked Potential (mfVEP) and the automated perimetry. Color was evaluated with the Lanthony D15d and Cambridge Colour Test 2.0. Automatic static perimetry used the white-on-white 24-2 protocol of the Humphrey Field Analyzer II-750i. Visual field was also evaluated with the mfVEP system Veris Science 5.2.4. Contrast sensitivity was measured with Metropsis software, using sine wave gratings of 0,2; 0,5; 1,0; 2,0; 5,0; 10,0 and 20,0 cpd. Results: The results for the two groups were compared using the Mann-Whitney U test. In the color discrimination test, the groups were significantly different for the thresholds in the three confusion axis tested (p<0,05), area of the ellipse (p<0,01) and ellipticity (p<0,05). In the color arrangement test, the two groups were significantly different (p<0,01). The automated perimetry results were also significantly different between groups for the 90, 150 e 210 eccentricity rings (p<0,05) and the MD and PSD values (p<0,05). Only three of the workers were tested with the mfVEP so far. All three had at least 30 sectors in the visual field 10 with significant loss of amplitude in the response (p<0,05, when compared to normative data). This result was not observed in the control group. The Spearman correlation coefficient was used to look for significant correlations between time of work and visual performance. For color vision, we found significant positive correlation between time of work and indexes of the Lanthony D15d (p=0,52; p<0,05) and deutan axis thresholds (p=0,59; p<0,05) for the CCT test. The analysis of sensitivity in eccentricity rings of perimetry data showed significant negative correlation with the time of work for the Fovea (p=-051; p<0,05) and rings of 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). The contrast sensitivity data was not significantly correlated with time of work. Conclusions: The results presented here suggest that chronic occupational exposure to organic solvents leads to changes in the visual system function even when the exposure is within occupational safety limits. The results also suggest that the visual changes are extensive and diffus

    Data

    No full text

    Configural superiority for varying contrast levels

    No full text

    Code

    No full text
    corecore