    Regional and overall ventilation inhomogeneities in preterm and term-born infants

    Get PDF
    Objectives: We compared ventilation inhomogeneity assessed by electrical impedance tomography (EIT) and multiple breath washout (MBW) in preterm and term-born infants. We hypothesised that EIT measurements in spontaneously breathing infants are repeatable and that differences in regional ventilation distribution measured by EIT can distinguish between preterm and term-born infants. Design: Cross-sectional group comparison study. Setting: Lung function laboratory at a University Children's Hospital. Participants: Seventeen healthy term-born and 15 preterm infants at a matched postmenstrual age of 44weeks. Measurements and results: We concurrently measured ventilation inhomogeneity by EIT, ventilation inhomogeneity (LCI) and functional residual capacity (FRC) by MBW and tidal breathing variables during unsedated quiet sleep. EIT measurements were highly repeatable (coefficient of variation 3.6%). Preterm infants showed significantly more ventilation of the independent parts of the lungs compared to healthy term-born infants assessed by EIT (mean difference 5.0, 95 CI 1.3-8%). Whereas the two groups showed no differences in lung volumes or ventilation inhomogeneities assessed by MBW, EIT discriminated better between term and preterm infants. (FRC/kg: mean difference 1.1mL, 95% CI −1.4-3.8mL; LCI: mean difference 0.03, 95% CI −0.32-0.25). Conclusions: EIT shows distinct differences in ventilation distribution between preterm and term-born infants, which cannot be detected by MBW. Although preterm infants are capable of dynamically maintaining overall functional residual volume and ventilation distribution, they show some spatial differences from fullterm infant

    浅析SANTO PAULUS 高中二年级理科学生的汉语学习困难

    Get PDF
    AbstractIn Pontianak some schools have opened Chinese classes, and some schools have turned Chinese classes into compulsory courses. However, students listening, speaking, reading and writing abilities in Chinese classroom learning are insufficient. Students encounter some difficulties in learning Chinese, so they find it difficult to learn Chinese. The author investigates the second grade science students in Santo Paulus High School, and analyses the factors of students difficulty in learning Chinese. This paper uses the questionnaire method to analyze the students learning situation. Summarize some learning difficulties that Santo Paulus High School sophomores also encounter, such as: Chinese teachers do not adequately carry out the principle of "helping students to improve efficiency"; teachers do not give enough consideration to teaching methods; teachers choose textbooks that are not suitable for students; students learning attitude is not positive and credible enough; The arrangement of teaching environment is not reasonable. Keywords: Learning, Learning Difficulties, Chines

    Tidal Volume Single Breath Washout of Two Tracer Gases - A Practical and Promising Lung Function Test

    Get PDF
    Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF(6)) and helium (He) using an ultrasonic flowmeter (USFM)

    Lung Volume, Breathing Pattern and Ventilation Inhomogeneity in Preterm and Term Infants

    Get PDF
    BACKGROUND: Morphological changes in preterm infants with bronchopulmonary dysplasia (BPD) have functional consequences on lung volume, ventilation inhomogeneity and respiratory mechanics. Although some studies have shown lower lung volumes and increased ventilation inhomogeneity in BPD infants, conflicting results exist possibly due to differences in sedation and measurement techniques. METHODOLOGY/PRINCIPAL FINDINGS: We studied 127 infants with BPD, 58 preterm infants without BPD and 239 healthy term-born infants, at a matched post-conceptional age of 44 weeks during quiet natural sleep according to ATS/ERS standards. Lung function parameters measured were functional residual capacity (FRC) and ventilation inhomogeneity by multiple breath washout as well as tidal breathing parameters. Preterm infants with BPD had only marginally lower FRC (21.4 mL/kg) than preterm infants without BPD (23.4 mL/kg) and term-born infants (22.6 mL/kg), though there was no trend with disease severity. They also showed higher respiratory rates and lower ratios of time to peak expiratory flow and expiratory time (t(PTEF)/t(E)) than healthy preterm and term controls. These changes were related to disease severity. No differences were found for ventilation inhomogeneity. CONCLUSIONS: Our results suggest that preterm infants with BPD have a high capacity to maintain functional lung volume during natural sleep. The alterations in breathing pattern with disease severity may reflect presence of adaptive mechanisms to cope with the disease process

    Complexity and respiratory growth: a developing story

    No full text

    Fractals for physicians

    No full text
    There is increasing interest in the study of fractals in medicine. In this review, we provide an overview of fractals, of techniques available to describe fractals in physiological data, and we propose some reasons why a physician might benefit from an understanding of fractals and fractal analysis, with an emphasis on paediatric respiratory medicine where possible. Among these reasons are the ubiquity of fractal organisation in nature and in the body, and how changes in this organisation over the lifespan provide insight into development and senescence. Fractal properties have also been shown to be altered in disease and even to predict the risk of worsening of disease. Finally, implications of a fractal organisation include robustness to errors during development, ability to adapt to surroundings, and the restoration of such organisation as targets for intervention and treatment

    Broadband frequency dependence of respiratory impedance in rats

    No full text
    Past studies in humans and other species have revealed the presence of resonances and antiresonances, i.e., minima and maxima in respiratory system impedance (Zrs), at frequencies much higher than those commonly employed in clinical applications of the forced oscillation technique (FOT). To help understand the mechanisms behind the first occurrence of antiresonance in the Zrs spectrum, the frequency response of the rat was studied by using FOT at both low and high frequencies. We measured Zrs in both Wistar and PVG/c rats using the wave tube technique, with a FOT signal ranging from 2 to 900 Hz. We then compared the high-frequency parameters, i.e., the first antiresonant frequency (far,1) and the resistive part of Zrs at that frequency [Rrs(far,1)], with parameters obtained by fitting a modified constant-phase model to low-frequency Zrs spectra. The far,1 was 570 +/- 43 (SD) Hz and 456 +/- 16 Hz in Wistar and PVG/c rats, respectively, and it did not shift with respiratory gases of different densities (air, heliox, and a, mixture of SF6). The far, 1 and Rrs-(far, 1) were relatively independent of methacholine-induced bronchoconstriction but changed significantly with increasing transrespiratory pressures up to 20 cmH(2)O, in the same way as airway resistance but independently of changes to tissue parameters. These results suggest that, unlike the human situation, the first antiresonance in the rat is not primarily dependent on the acoustic dimensions of the respiratory system and can be explained by interactions between compliances and inertances localized to the airways, but this most likely does not include airway wall compliance

    Dismantling airway disease with the use of new pulmonary function indices

    No full text
    We are currently limited in our abilities to diagnose, monitor disease status and manage chronic airway disease like asthma and chronic obstructive pulmonary disease (COPD). Conventional lung function measures often poorly reflect patient symptoms or are insensitive to changes, particularly in the small airways where disease may originate or manifest. Novel pulmonary function tests are becoming available which help us better characterise and understand chronic airway disease, and their translation and adoption from the research arena would potentially enable individualised patient care. In this article, we aim to describe two emerging lung function tests yielding novel pulmonary function indices, the forced oscillation technique (FOT) and multiple breath nitrogen washout (MBNW). With a particular focus on asthma and COPD, this article demonstrates how chronic airway disease mechanisms have been dismantled with the use of the FOT and MBNW. We describe their ability to assess detailed pulmonary mechanics for diagnostic and management purposes including response to bronchodilation and other treatments, relationship with symptoms, evaluation of acute exacerbations and recovery, and telemonitoring. The current limitations of both tests, as well as open questions/directions for further research, are also discussed