213 research outputs found

    Ultrasound in the evaluation of enthesitis: Status and perspectives

    Get PDF
    Introduction: An increasing number of studies have applied ultrasound to the evaluation of entheses in spondyloarthritis patients. However, no clear agreement exists on the definition of enthesitis, on the number and choice of entheses to examine and on ultrasound technique, which may all affect the results of the examination. The objectives of this study were to first determine the level of homogeneity in the ultrasound definitions for the principal lesions of enthesitis in the published literature and second, to evaluate the metric properties of ultrasound for detecting enthesitis according to the OMERACT filter.Methods: Search was performed in PUBMED and EMBASE. Both grey-scale and Doppler definitions of enthesitis, including describing features of enthesitis, were collected and metrological qualities of studies were assessed.Results: After selection, 48 articles were analyzed. The definition of ultrasound enthesitis and elementary features varied among authors. Grey-scale enthesitis was characterized by increasing thickness (94% of studies), hypoechogenicity (83%), enthesophytes (69%), erosions (67%), calcifications (52%), associated bursitis (46%) and cortical irregularities (29%). Only 46% of studies reported the use of Doppler. High discrepancies were observed on frequency, type of probe and Doppler mode used. Face and content validity were the most frequently evaluated criteria (43%) followed by reliability (29%) and responsiveness (19%).Conclusions: Ultrasound has evidence to support face, content validity and reliability for the evaluation of enthesitis, though there is a lack of well-reported methodology in most of the studies. Consensus on elementary lesions and standardization of exam is needed to determine the ultrasound definition of enthesitis in grey-scale and in Doppler for future applications. © 2011 Gandjbakhch et al.; licensee BioMed Central Ltd

    Structural damage in rheumatoid arthritis assessed by musculoskeletal ultrasound: A systematic literature review by the Structural Joint Damage Task Force of the OMERACT Ultrasound Working Group

    Get PDF
    Objectives: To identify and synthesize the evidence for the use and measurement properties of musculoskeletal ultrasound in assessing structural joint damage in patients with rheumatoid arthritis (RA).Methods: A systematic literature search (SLR) of the PubMed, Embase and Cochrane Library was performed. Original articles were included published in English reporting on ultrasound of bone erosion, cartilage damage and the measurement properties of ultrasound according to the OMERACT filter 2.1.Results: Of the 1.495 identified articles 149 were included in the final review, most of which reported on cross-sectional studies and used the OMERACT definitions for ultrasonographic pathology. Among these, bone erosions were assessed in 139 (93.3%), cartilage damage in 24 (16.1%), enthesophytes in 8 (5.4%), osteophytes in 15 (10.1%) and malalignment and ankylosis in a single (0.9%) study, respectively. Most studies (126/149, 84.6%) assessed the joints of the hands. The overwhelming majority of studies (127/149, 85.2%) assessed structural joint damage bilaterally. Validity, reliability and responsiveness were assessed in 21 (14.1%), 34 (22.8%) and 17 (11.4%) studies, respectively.Conclusion: While the results of this SLR suggest that ultrasound is a sensitive, reliable and feasible tool to detect damage in RA, they also highlight the need for further research and validation. Findings of this SLR will inform the next steps of the OMERACT Ultrasound Working Group in developing an ultrasound score for assessing structural joint damage in patients with RA.(c) 2021 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/

    Clinical Examination, Ultrasound and MRI Imaging of The Painful Elbow in Psoriatic Arthritis and Rheumatoid Arthritis: Which is Better, Ultrasound or MR, for Imaging Enthesitis?

    Get PDF
    Introduction: The purpose of the current study was to examine the painful elbow, and in particular enthesitis, in psoriatic arthritis (PsA) and rheumatoid arthritis (RA) using clinical examination, ultrasonography (US) and magnetic resonance imaging (MRI). Methods: Patients with elbow pain (11 with PsA and 9 with RA) were recruited. Clinical examination, US and MRI studies were performed on the same day. For enthesitis, the common extensor and flexor insertions and the triceps insertion were imaged (20 patients, giving a total of 60 sites with comparative data). Imaging was performed with the radiologists blinded to the diagnosis and clinical findings. US was used to assess ‘inflammatory activity’ (Power Doppler signal, oedema, tendon thickening and bursal swelling) and ‘damage’ (erosions, cortical roughening and enthesophytes). MRI was used to assess ‘inflammation’ (fluid in paratenon, peri-entheseal soft-tissue oedema, entheseal enhancement with gadolinium, entheseal oedema and bone oedema) and ‘damage’ (erosion, cortical roughening and enthesophyte). Results: Complete scan data were not available for all patients as one patient could not tolerate the MRI examination. No significant differences in imaging scores were found between PsA and RA. Analysis of damage scores revealed complete agreement between US and MRI data in 43/55 (78%) comparisons; in 10/55 (18%) cases the US data were abnormal but the MRI data normal; in 2/55 (4%) cases, the MRI data were abnormal and the US data normal. Analysis of the inflammation scores revealed complete agreement between US and MRI data in 33/55 (60%) comparisons; in 3/55 (5%) cases US data were abnormal but MRI data normal; in 19/55 (35%) cases the MRI data were abnormal and the US data normal. There was a poor relationship between assessments based on clinical examination and imaging studies. Readers could not accurately identify the disease from imaging findings. Conclusion: Based on our results, at the elbow, US and MR have different roles in assessing enthesitis, with US apparently the better diagnostic tool for assessing damage and MR the better tool for assessing inflammation. In this study enthesitis and synovitis in the painful elbow were found equally in cases of established RA and PsA

    Scoring ultrasound synovitis in Rheumatoid Arthritis: a EULAR-OMERACT Ultrasound Taskforce–Part 1: definition and development of a standardized, consensus-based scoring system

    Get PDF
    Objectives: To develop a consensus-based ultrasound (US) definition and quantification system for synovitis in rheumatoid arthritis (RA). Methods: A multistep, iterative approach was used to: (1) evaluate the baseline agreement on defining and scoring synovitis according to the usual practice of different sonographers, using both grey-scale (GS) (synovial hypertrophy (SH) and effusion) and power Doppler (PD), by reading static images and scanning patients with RA and (2) evaluate the influence of both the definition and acquisition technique on reliability followed by a Delphi exercise to obtain consensus definitions for synovitis, elementary components and scoring system. Results: Baseline reliability was highly variable but better for static than dynamic images that were directly acquired and immediately scored. Using static images, intrareader and inter-reader reliability for scoring PD were excellent for both binary and semiquantitative (SQ) grading but GS showed greater variability for both scoring systems (κ ranges: −0.05 to 1 and 0.59 to 0.92, respectively). In patient-based exercise, both intraobserver and interobserver reliability were variable and the mean κ coefficients did not reach 0.50 for any of the components. The second step resulted in refinement of the preliminary Outcome Measures in Rheumatology synovitis definition by including the presence of both hypoechoic SH and PD signal and the development of a SQ severity score, depending on both the amount of PD and the volume and appearance of SH. Conclusion: A multistep consensus-based process has produced a standardised US definition and quantification system for RA synovitis including combined and individual SH and PD components. Further evaluation is required to understand its performance before application in clinical trials

    Accuracy of synovial fluid analysis compared to histology for the identification of calcium pyrophosphate crystals: An ancillary study of the OMERACT US working group - CPPD subgroup

    Get PDF
    The aim of this study was to evaluate the accuracy of synovial fluid analysis in the identification of calcium pyrophosphate dihydrate crystals compared to microscopic analysis of joint tissues as the reference standard. This is an ancillary study of an international, multicentre cross-sectional study performed by the calcium pyrophosphate deposition disease (CPPD) subgroup of the OMERACT Ultrasound working group. Consecutive patients with knee osteoarthritis (OA) waiting for total knee replacement surgery were enrolled in the study from 2 participating centres in Mexico and Romania. During the surgical procedures, synovial fluid, menisci and hyaline cartilage were collected and analysed within 48 hours from surgery under transmitted light microscopy and compensated polarised light microscopy for the presence/absence of calcium pyrophosphate crystals. All slides were analysed by expert examiners on site, blinded to other findings. A dichotomic score (absence/presence) was used for scoring both synovial fluid and tissues. Microscopic analysis of knee tissues was considered the gold standard. Sensitivity, specificity, accuracy, positive and negative predictive values of synovial fluid analysis in the identification of calcium pyrophosphate crystals were calculated.15 patients (53% female, mean age 68 yo +/- 8.4) with OA of grade 3 or 4 according to Kellgren-Lawrence scoring were enrolled. 12 patients (80%) were positive for calcium pyrophosphate crystals at the synovial fluid analysis and 14 (93%) at the tissue microscopic analysis. The overall diagnostic accuracy of synovial fluid analysis compared with histology for CPPD was 87%, with a sensitivity of 86% and a specificity of 100%, the positive predictive value was 100% and the negative predictive value was 33%.In conclusion synovial fluid analysis proved to be an accurate test for the identification of calcium pyrophosphate dihydrate crystals in patients with advanced OA

    Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis

    Get PDF
    Objective. To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods.Methods. Thirteen observers examined nine patients with RA and one healthy individual in two rounds independently and blindly of each other. Each round consisted of two consecutive examinations, an anatomy-based examination and a free examination according to personal preferences. The following tendons were evaluated: wrist extensor compartments 2, 4 and 6, finger flexor tendons 3 and 4 at MCP level, tibialis posterior tendon and both peronei tendons. Overall, positive and negative agreements and \u3ba-values for greyscale (GS) tenosynovitis, peritendinous power Doppler (PPD) signal, intratendinous power Doppler (IPD) signal and GS tendon damage were calculated.Results. Intraobserver \u3ba-value ranges were 0.53-0.55 (P < 0.0005) for GS tenosynovitis, 0.61-0.64 (P < 0.0005) for PPD signal, 0.65-0.66 (P < 0.0005) for IPD signal and 0.44-0.53 (P < 0.0005) for GS tendon damage. For interobserver reliability, substantial overall agreement ranged from 80 to 89% for GS tenosynovitis, 97 to 100% for PPD signal, 97 to 100% for IPD signal and 97 to 100% for GS tendon damage. Results were independent of scanning technique.Conclusion. Intraobserver reliability for tenosynovitis and tendon damage varied from moderate for GS to good for PD. Overall interobserver reliability for tenosynovitis and tendon damage was excellent both for GS and PD. This qualitative scoring system may serve as the first step to a semi-quantitative score for tendon pathology. \ua9 The Author 2012. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved
    • …
    corecore