1,677 research outputs found

    Monopole search below the Parker limit with the MACRO detector at Gran Sasso

    Get PDF
    The MACRO detector approved for the Gran Sasso Underground Laboratory in Italy will be the first capable of performing a definitive search for super-massive grand unified theory (GUT) monopoles at a level significantly below the Parker flux limit of 10 to the minus 15th power square centimeters Sr(-1) 5(-1). GUT monopoles will move at very low velocities (V approx. 0.001 c) relative to the Earth and a multifaceted detection technique is required to assume their unambiguous identification. Calculations of scintillator response to slow monopoles and measurements of scintillation efficiency for low energy protons have shown that bare monopoles and electrically charged monopoles moving at velocities as low as 5 x .0001 c will produce detectable scintillation signals. The time-of-flight between two thick (25 cm) liquid scintillation layers separated by 4.3m will be used in conjunction with waveform digitization of signals of extended duration in each thick scintillator to provide a redundant signature for slow penetrating particles. Limited streamer tubes filled with He and n-pentane will detect bare monopoles with velocities as low as 1 x 0.0001 c by exploiting monopole induced level mixing and the Penning effect

    Track recording plastic compositions

    Get PDF
    Improved nuclear track recording plastic compositions are provided which exhibit greatly decreased surface roughness when etched to produce visible tracks of energetic nuclear particles which have passed into and/or through said plastic. The improved compositions incorporate a small quantity of a phthalic acid ester into the major plastic component which is derived from the polymerization of monomeric di-ethylene glycol bis allyl carbonate. Di-substituted phthalic acid esters are preferred as the added component, with the further perference that the ester substituent has a chain length of 2 or more carbon atoms. The inclusion of the phthalic acid ester to an extent of from about 1-2% by weight of the plastic compositions is sufficient to drastically reduce the surface roughness ordinarily produced when the track recording plastic is contacted by etchants

    Near threshold response of a wave shifted Cerenkov radiator to heavy ions

    Get PDF
    The response of Pilot 425 to heavy ions with energies less than 600 MeV/amu beta approximately 0.8 is examined both theoretically and experimentally. Measurements are presented from an experiment which employed a Ne-20 beam at many energies below 575 MeV/amu. The signal is assumed to come from three sources: (1) Cerenkov light from the heavy ion, (2) Cerenkov light from secondary electrons, and (3) scintillation of the radiator. It is found that the effective index of refraction is 1.518 and that scintillation is present at a level of approximately 2.7 percent of the Cerenkov signal for beta = 1 for Ne-20. The first of these values differs from values previously quoted in the literature

    Exhibiting respect: Investigating ethical practice for the display of human remains in museums

    Get PDF
    Museums have long displayed human remains from archaeological and other contexts to educate the public about human health, spiritual beliefs, and customs, and to encourage reflection about death and dying. However, since the 1950s, repatriation movements and decolonizing dialogues have inspired global discussions about who has the right to retain and display human remains. Subsequent changes in attitude are now reflected in international ethical guidelines and accords that emphasize “respect” for human remains and for originating communities. Most museums will no longer display Indigenous Ancestors, but whether and how to display other human remains presents an unresolved ethical dilemma. Should other archaeological human remains be exhibited without consent? If so, how can they be displayed respectfully? Do visitors wish to see human remains in museums? This dissertation is a pilot study that examined three dimensions of these ethical challenges: 1) how has the display of human remains changed over time—particularly in Anglo-North America and Western Europe?; 2) how does the public in North America feel about the display of human remains?; and 3) how can human remains be displayed “with respect”? I focused on Anglo-North America and Western Europe as instrumental case studies to illuminate these emerging issues due to their accessibility, recent ethical dialogue, and changing museum practices in these regions. My research explored these questions using the principles of New Museology and radical transparency: i.e., proactively engaging the public and encouraging them to participate in ethical decision-making. In this work, I: 1) explore ethical changes and challenges for museums in relation to the display of human remains; 2) facilitate public engagement with ethical discourse about the display of human remains; 3) explore the concept of “respectful display” of human remains; and 4) make recommendations for museum professionals deciding whether to display of human remains. These issues are particularly important as museums strive to decolonize and become more inclusive

    High resolution Cerenkov and range detectors for balloon-borne cosmic-ray experiment

    Get PDF
    A combination of an active Cerenkov detector and passive range detectors is proposed for the high resolution measurement of isotopic composition in the neighborhood of iron in the galactic cosmic rays. A large area (4,300 sq cm) Cerenkov counter and passive range detectors were tested. Tests with heavy ions (2.1 GeV/amu C-12, 289 MeV/amu Ar-40, and 594 MeV/amu Ne-20) revealed the spatial uniformity of response of the Cerenkov counter to be better than 1% peak-to-peak. Light collection efficiency is independent of projectile energy and incidence angle to within at least 0.5%. Passive Lexan track recorders to measure range in the presence of the nuclear interaction background which results from stopping particles through 0.9 interaction lengths of matter were also tested. It was found that nuclear interactions produce an effective range straggling distribution only approximately 75% wider than that expected from range straggling alone. The combination of these tested techniques makes possible high mass resolution in the neighborhood of iron

    Investigating reciprocity failure in 1.7-micron cut-off HgCdTe detectors

    Full text link
    Flux dependent non-linearity (reciprocity failure) in HgCdTe NIR detectors with 1.7 micron cut-off was investigated. A dedicated test station was designed and built to measure reciprocity failure over the full dynamic range of near infrared detectors. For flux levels between 1 and 100,000 photons/sec a limiting sensitivity to reciprocity failure of 0.3%/decade was achieved. First measurements on several engineering grade 1.7 micron cut-off HgCdTe detectors show a wide range of reciprocity failure, from less than 0.5%/decade to about 10%/decade. For at least two of the tested detectors, significant spatial variation in the effect was observed. No indication for wavelength dependency was found. The origin of reciprocity failure is currently not well understood. In this paper we present details of our experimental set-up and show the results of measurements for several detectors.Comment: 11 pages, 10 figures, to appear in " Astronomical Telescopes and Instrumentation: High Energy, Optical, and Infrared Detectors for Astronomy IV", Proceedings of SPIE Vol. 774

    Napoleon in Russia

    Get PDF
    https://stars.library.ucf.edu/prism/1585/thumbnail.jp
    corecore