9 research outputs found

    Triagem primária de doadores de sangue por teste de ácidos nucléicos: desenvolvimento de um método não-comercial e resultados

    Get PDF
    An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.Desenvolveu-se uma metodologia própria ("in-house") baseada em RT-PCR, que permite detectar simultaneamente o RNA do vírus HCV e de um RNA artificial empregado como controle externo. As amostras são analisadas em pools de 6-12 doações, cada doação sendo incluída em dois pools diferentes, um horizontal e um vertical, permitindo a identificação imediata de uma doação reativa, sem a necessidade de desmembrar-se um pool reativo. O processo todo consumiu de 6-8 horas diárias e os resultados foram emitidos em paralelo à sorologia. O método detectou os seis genótipos de HCV, com um limite de sensibilidade de 500 UI/mL (95% hit rate). Até julho de 2005 haviam sido testadas 139.678 doações com a detecção de 315 (0,23%) doações reativas para HCV-RNA. Exceto cinco falso-positivas, todas estas doações também apresentavam o respectivo anticorpo, portanto não se detectou nenhuma doação em janela imunológica. A especificidade foi de 99,83%. A detecção de amostra em janela imunológica, nesta população de doadores, provavelmente demandará a análise de um número maior de doações, espelhando-se na experiência internacional que tem mostrado a detecção de amostras HCV-RNA isoladas em 1:200.000 - 1:500.000 doações

    Substituição do teste de p24 Ag (HIV) por um RT-PCR multiplex na triagem primária de doadores de sangue

    Get PDF
    O uso de testes de ácidos nucleicos (NAT) na rotina de triagem de doadores de sangue tornou-se uma realidade ao final da década de 1990. Descreve-se aqui uma metodologia de RT-PCR multiplex "in-house" que permite a detecção simultânea dos RNAs dos vírus HIV e HCV além de uma molécula artificial de RNA usada como controle externo. O método detecta todos os subtipos de HIV do grupo M e também do grupo N e O, com uma sensibilidade de 500 UI/mL. Após validação, este teste substituiu o do antígeno p24, até então na rotina de triagem em nosso laboratório, desde 1996. De julho de 2001 a fevereiro de 2006 foram testadas 102.469 doações e 41 (0.04%) foram NAT reativas. Uma doação NAT isoladamente reativa (anticorpo não-reativa) foi detectada com soroconversão subseqüente do doador, portanto, o rendimento do NAT nesta população até o presente momento é de 1:102.469. Este número contrasta com a experiência obtida internacionalmente, onde taxas de 1:600.000 - 1:3.100.000 foram descritas.Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations

    Determinação pré-natal do sexo fetal por meio da análise de DNA no plasma materno Prenatal fetal gender determination by analysis of DNA from maternal pasma

    No full text
    OBJETIVO: avaliar um novo método de determinação do sexo fetal pela análise de DNA obtido do plasma materno. MÉTODOS: sangue periférico (10 mL) foi coletado de mulheres grávidas em diferentes idades gestacionais. O plasma foi separado e o DNA isolado do mesmo foi submetido à reação em cadeia da polimerase (PCR) com oligonucleotídeos iniciadores derivados do gene DYS14 específico do cromossomo Y. RESULTADOS: foram analisadas amostras de 212 pacientes. O resultado da PCR foi comparado ao sexo determinado pela ultra-sonografia e/ou do nascimento. Houve concordância em 209 das 212 pacientes. Nos 3 casos discordantes a PCR apontou resultado feminino, sendo as três amostras coletadas antes da 8ª semana de gravidez. CONCLUSÃO: o método de PCR desenvolvido para a determinação do sexo fetal possui excelente sensibilidade e especificidade, permitindo seu uso rotineiro. O resultado de sexo masculino possui maior confiabilidade que o feminino, principalmente em idade gestacional precoce. Novas aplicações para o DNA fetal no plasma materno estão sendo pesquisadas, permitindo no futuro o diagnóstico não invasivo de uma série de doenças.<br>PURPOSE: to evaluate a new method of fetal sex determination through the analysis of DNA from maternal plasma. METHODS: peripheral blood (10 mL) was drawn from pregnant women in different gestational ages. Plasma was separated and isolated DNA was submitted to the polymerase chain reaction (PCR) with primers from the Y-chromosome-specific gene DYS14. RESULTS: two hundred and twelve patients were enrolled. PCR results were compared to either confirmatory ultrasonography and/or birth. Agreement was observed in 209 samples. Discordant plasmas had a PCR result of female fetus and all of them were derived from mothers with less than 8 weeks of pregnancy. CONCLUSION: the PCR method developed for fetal sex determination has excellent sensitivity and specificity, permitting its use as a routine test. A PCR result of male fetus presents a higher confidence than a female one, specially in early gestational periods. New applications employing fetal DNA from maternal plasma are being developed and hopefully will allow noninvasive diagnosis of several conditions

    Alta prevalência do RNA do vírus da hepatite G (HGV) em doadores de sangue brasileiros

    Get PDF
    The aim of this study was to investigate the presence of the Hepatitis G Virus on a population of blood donors from São Paulo, Brazil and to evaluate its association to sociodemographic variables. Two RT-PCR systems targeting the putative 5'NCR and NS3 regions were employed and the former has shown a higher sensitivity. The observed prevalence of HGV-RNA on 545 blood donors was 9.7% (CI 95% 7.4;12.5). Statistical analysis depicted an association with race/ethnicity, black and mulatto donors being more frequently infected; and also with years of education, less educated donors presenting higher prevalences. No association was observed with other sociodemographic parameters as age, gender, place of birth and of residence. DNA sequencing of nine randomly chosen isolates demonstrated the presence of genotypes 1, 2 and 3 among our population but clustering of these Brazilian isolates was not detected upon phylogenetic analysis.O objetivo deste estudo foi investigar a presença do vírus da hepatite G e sua associação com variáveis sóciodemográficas em uma população de doadores de sangue da cidade de São Paulo, Brasil. Dois sistemas de PCR foram empregados, um focando a região 5' não-codificadora e outro a região não-estrutural 3, apresentando o primeiro maior sensibilidade. A prevalência detectada do HGV-RNA em 545 doadores foi de 9,7% (IC 95% 7,4;12,5). A prevalência do HGV-RNA foi significativamente maior em doadores da raça negra/mulata (26,5%) quando comparados aos doadores caucasianos (7,5%), (OR = 4,5). Também foi observada uma tendência de maiores prevalências em doadores de menor escolaridade. Não se observou associação significativa com outros parâmetros estudados como idade, sexo, origem geográfica e local de residência. O sequenciamento do DNA de nove isolados selecionados ao acaso demonstrou a presença dos genótipos 1, 2 e 3, mas não houve um agrupamento das amostras brasileiras quando submetidas à análise filogenétic

    High prevalence of GB Virus C/Hepatitis G Virus RNA among Brazilian blood donors

    Get PDF
    The aim of this study was to investigate the presence of the Hepatitis G Virus on a population of blood donors from São Paulo, Brazil and to evaluate its association to sociodemographic variables. Two RT-PCR systems targeting the putative 5'NCR and NS3 regions were employed and the former has shown a higher sensitivity. The observed prevalence of HGV-RNA on 545 blood donors was 9.7% (CI 95% 7.4;12.5). Statistical analysis depicted an association with race/ethnicity, black and mulatto donors being more frequently infected; and also with years of education, less educated donors presenting higher prevalences. No association was observed with other sociodemographic parameters as age, gender, place of birth and of residence. DNA sequencing of nine randomly chosen isolates demonstrated the presence of genotypes 1, 2 and 3 among our population but clustering of these Brazilian isolates was not detected upon phylogenetic analysis

    Three Cases of Infection with Hepatitis C Virus Genotype 5 among Brazilian Hepatitis Patients

    No full text
    During the course of routine genotyping of hepatitis C virus isolates by 5′ noncoding region sequencing, three samples were found to bear genotype 5-specific nucleotides. A serotyping method was subsequently applied and confirmed the finding. This is the first report of the occurrence of genotype 5 in Brazil

    Primary screening of blood donors by nat testing for HCV-RNA: development of an "in-house" method and results Triagem primária de doadores de sangue por teste de ácidos nucléicos: desenvolvimento de um método não-comercial e resultados

    Get PDF
    An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.<br>Desenvolveu-se uma metodologia própria ("in-house") baseada em RT-PCR, que permite detectar simultaneamente o RNA do vírus HCV e de um RNA artificial empregado como controle externo. As amostras são analisadas em pools de 6-12 doações, cada doação sendo incluída em dois pools diferentes, um horizontal e um vertical, permitindo a identificação imediata de uma doação reativa, sem a necessidade de desmembrar-se um pool reativo. O processo todo consumiu de 6-8 horas diárias e os resultados foram emitidos em paralelo à sorologia. O método detectou os seis genótipos de HCV, com um limite de sensibilidade de 500 UI/mL (95% hit rate). Até julho de 2005 haviam sido testadas 139.678 doações com a detecção de 315 (0,23%) doações reativas para HCV-RNA. Exceto cinco falso-positivas, todas estas doações também apresentavam o respectivo anticorpo, portanto não se detectou nenhuma doação em janela imunológica. A especificidade foi de 99,83%. A detecção de amostra em janela imunológica, nesta população de doadores, provavelmente demandará a análise de um número maior de doações, espelhando-se na experiência internacional que tem mostrado a detecção de amostras HCV-RNA isoladas em 1:200.000 - 1:500.000 doações
    corecore