38 research outputs found

    Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging

    Get PDF
    Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT+). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with Tc-99m-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT+ for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT+. In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT+) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup

    Factors associated with good self-rated health of non-disabled elderly living alone in Japan: a cross-sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Self-rated health (SRH) is reported as a reliable predictor of disability and mortality in the aged population and has been studied worldwide to enhance the quality of life of the elderly. Nowadays, the elderly living alone, a particular population at great risk of suffering physical and mental health problems, is increasing rapidly in Japan and could potentially make up the majority of the aged population. However, few data are available pertaining to SRH of this population. Given the fact that sufficient healthcare is provided to the disabled elderly whereas there is little support for non-disabled elderly, we designed this population-based survey to investigate SRH of non-disabled elderly living alone and to identify the factors associated with good SRH with the purpose of aiding health promotion for the elderly.</p> <p>Methods</p> <p>A cross-sectional study was conducted in a metropolitan suburb in Japan. Questionnaires pertaining to SRH and physical conditions, lifestyle factors, psychological status, and social activities, were distributed in October 2005 to individuals aged ≥ 65 years and living alone. Response rate was 75.1%. Among these respondents, a total of 600 male and 2587 female respondents were identified as non-disabled elderly living alone and became our subjects. Multivariate logistic regression was used to identify the factors associated with good SRH and sex-specific effect was tested by stepwise logistic regression.</p> <p>Results</p> <p>Good SRH was reported by 69.8% of men and 73.8% of women. Multivariate logistic regression analysis showed that good SRH correlated with, in odds ratio sequence, "can go out alone to distant places", no depression, no weight loss, absence of self-rated chronic disease, good chewing ability, and good visual ability in men; whereas with "can go out alone to distant places", absence of self-rated chronic disease, no weight loss, no depression, no risk of falling, independent IADL, good chewing ability, good visual ability, and social integration (attend) in women.</p> <p>Conclusion</p> <p>For the non-disabled elderly living alone, sex-appropriate support should be considered by health promotion systems from the view point of SRH. Overall, the ability to go out alone to distant places is crucial to SRH of both men and women.</p

    The Balance of Individual and Infrastructure Values in Decisions Regarding Advanced Science and Technology

    No full text
    A country&rsquo;s scientific technology policy rarely reflects public opinion. In this study, we created a hierarchical model of societal well-being, comprising five value components for both individual and infrastructure well-being, to analyze the balance among these values. We conducted a survey in two stages; first, both individual and infrastructure well-being were investigated, and then the weights between pairs of value categories composing individual and infrastructure well-being were scored to assess which categories were most important. The analysis of the first stage used the score magnitudes, while that of the second stage used the analytic hierarchy process. The results showed that people value individual well-being more than infrastructure well-being. For both types of well-being, values related to the economy and safety were ranked as more important than the other values, but the weights were distributed over all value components. For individual well-being, the most important value category was the one related to safety, while for infrastructure well-being, it was economy. Therefore, people prioritize different values for themselves and for society as a whole. This suggests that when making decisions regarding technology, it is necessary to understand its effects on all fields and consider the balance between the value categories of well-being

    Ability of artificial intelligence to diagnose coronary artery stenosis using hybrid images of coronary computed tomography angiography and myocardial perfusion SPECT

    No full text
    Abstract Background Detecting culprit coronary arteries in patients with ischemia using only myocardial perfusion single-photon emission computed tomography (SPECT) can be challenging. This study aimed to improve the detection of culprit regions using an artificial neural network (ANN) to analyze hybrid images of coronary computed tomography angiography (CCTA) and myocardial perfusion SPECT. Methods This study enrolled 59 patients with stable coronary artery disease (CAD) who had been assessed by coronary angiography within 60 days of myocardial perfusion SPECT. Two nuclear medicine physicians interpreted the myocardial perfusion SPECT and hybrid images with four grades of confidence, then drew regions on polar maps to identify culprit coronary arteries. The gold standard was determined by the consensus of two other nuclear cardiology specialist based on coronary angiography findings and clinical information. The ability to detect culprit coronary arteries was compared among experienced nuclear cardiologists and the ANN. Receiver operating characteristics (ROC) curves were analyzed and areas under the ROC curves (AUC) were determined. Results Using hybrid images, observer A detected CAD in the right (RCA), left anterior descending (LAD), and left circumflex (LCX) coronary arteries with 83.6%, 89.3%, and 94.4% accuracy, respectively and observer B did so with 72.9%, 84.2%, and 89.3%, respectively. The ANN was 79.1%, 89.8%, and 89.3% accurate for each coronary artery. Diagnostic accuracy was comparable between the ANN and experienced nuclear medicine physicians. The AUC was significantly improved using hybrid images in the RCA region (observer A: from 0.715 to 0.835, p = 0.0031; observer B: from 0.771 to 0.843, p = 0.042). To detect culprit coronary arteries in perfusion defects of the inferior wall without using hybrid images was problematic because the perfused areas of the LCX and RCA varied among individuals. Conclusions Hybrid images of CCTA and myocardial perfusion SPECT are useful for detecting culprit coronary arteries. Diagnoses using artificial intelligence are comparable to that by nuclear medicine physicians

    A case of a thoracic duct cyst extending from the mediastinum to the cisterna chyli resected using bilateral thoracoscopic surgery in the prone position

    No full text
    Abstract Background Thoracic duct cysts are extremely rare mediastinal tumors. We report a case of a thoracic duct cyst extending from the caudal aspect of the left main bronchus to the left renal artery that was safely and completely resected via bilateral thoracoscopic surgery in the prone position. Case presentation A 77-year-old male was referred to our hospital for follow-up computed tomography (CT) of prostate cancer, which revealed a mediastinal tumor and fatty low-density along the posterior mediastinum of the para-aortic artery with a slightly high-density component. Magnetic resonance imaging revealed a T2-weighted image with high intensity. The preoperative radiological diagnosis was lipoma or well-differentiated liposarcoma. CT in the prone position suggested that the tumor could be resected from the thoracic cavity to the caudal side, and bilateral thoracoscopic surgery was performed in the prone position. Based on the surgical findings, the tumor was diagnosed as a thoracic duct cyst rather than a lipoma. Dissection around the thoracic duct cyst was performed using a vessel-sealing system to prevent leakage of the chyle, and reliable clipping was performed to resect the cisterna chyli. Histopathological examination revealed smooth muscle structures around the cyst, suggestive of a thoracic duct cyst. The diagnosis of a thoracic duct cyst was made based on a high triglyceride level of 1310 mg/dL on examination of the milky-white cyst fluid. The patient's postoperative course was uneventful, and he was discharged 4 days postoperatively. A CT scan performed 13 months after surgery showed no recurrence. Conclusions A rare thoracic duct cyst extending from the mediastinum to the cisterna chyli was safely and completely resected using bilateral thoracoscopic surgery, with the patient in the prone position
    corecore