9,701 research outputs found

    Impact-picture predictions for the γγ\gamma\gamma total cross section at LEP

    Full text link
    We show that the rising total cross section σ(γγ→hadrons)\sigma(\gamma\gamma \to hadrons) recently observed by the L3 and OPAL Collaborations at LEP are fully consistent with the impact-picture for high-energy scattering. The impact picture is then used to predict this total cross section at higher energies. These experimental results confirm once more the success of the theoretical approach, which predicted for the first time, nearly thirty years ago, the universal increase of total cross sections at high energies.Comment: 5 pages, Latex, 1 figure. Revised versio

    Micro heat exchanger by using MEMS impinging jets

    Get PDF
    A micro impinging-jet heat exchanger is presented here. Heat transfer is studied for single jet, slot arrays and jet arrays. In order to facilitate micro heat transfer measurements with these devices, a MEMS sensor chip, which has an 8 x 8 temperature-sensor array on one side, and an integrated heater on the other side has been designed and fabricated. This sensor chip allows 2-D surface temperature measurement with various jets impinging on it. It is found that micro impinging jets can be highly efficient when compared to existing macro impinging-jet microelectronics packages such as IBM 4381. For example, using a single nozzle jet (500-Όm diameter driven by 5 psig pressure), the sensor chip (2 x 2 cm^2) temperature can be cooled down from 70 to 33°C. The cooling becomes more efficient when nozzle arrays (4x5 over 1 cm^2 area) are used under the same driving pressure. Interestingly, although higher driving pressure gives better cooling (lower surface temperature), the cooling efficiency, defined as h/0.5pv^2, is actually higher for lower driving pressure

    Complete gradient-LC-ESI system on a chip for protein analysis

    Get PDF
    This paper presents the first fully integrated gradient-elution liquid chromatography-electrospray ionization (LC-ESI) system on a chip. This chip integrates a pair of high-pressure gradient pumps, a sample injection pump, a passive mixer, a packed separation column, and an ESI nozzle. We also present the successful on-chip separation of protein digests by reverse phase (RP)-LC coupled with on-line mass spectrometer (MS) analysis

    Integrated parylene-cabled silicon probes for neural prosthetics

    Get PDF
    Recent advances in the field of neural prosthetics have demonstrated the thought control of a computer cursor. This capability relies primarily on electrode array surgically implanted into the brain as an acquisition source of neural activity. Various technologies have been developed for signal extraction; however most suffer from either fragile electrode shanks and bulky cables or inefficient use of surgical site areas. Here we present a design and initial testing results from high electrode density, silicon based arrays system with an integrated parylene cable. The greatly reduced flexible rigidity of the parylene cable is believed to relief possible mechanical damages due to relative motion between a brain and its skull

    Electrolysis-based diaphragm actuators

    Get PDF
    This work presents a new electrolysis-based microelectromechanical systems (MEMS) diaphragm actuator. Electrolysis is a technique for converting electrical energy to pneumatic energy. Theoretically electrolysis can achieve a strain of 136 000% and is capable of generating a pressure above 200 MPa. Electrolysis actuators require modest electrical power and produce minimal heat. Due to the large volume expansion obtained via electrolysis, small actuators can create a large force. Up to 100 ”m of movement was achieved by a 3 mm diaphragm. The actuator operates at room temperature and has a latching and reversing capability

    A suspended microchannel with integrated temperature sensors for high-pressure flow studies

    Get PDF
    A freestanding microchannel, with integrated temperature sensors, has been developed for high-pressure flow studies. These microchannels are approximately 20ÎŒm x 2ÎŒm x 4400ÎŒm, and are suspended above 80 ÎŒm deep cavities, bulk micromachined using BrF3 dry etch. The calibration of the lightly boron-doped thermistor-type sensors shows that the resistance sensitivity of these integrated sensors is parabolic with respect to temperature and linear with respect to pressure. Volumetric flow rates of N2 in the microchannel were measured at inlet pressures up to 578 psig. The discrepancy between the data and theory results from the flow acceleration in a channel, the non-parabolic velocity profile, and the bulging of the channel. Bulging effects were evaluated by using incompressible water flow measurements, which also measures 1.045x10^-3N-s/m^2 for the viscosity of DI water. The temperature data from sensors on the channel shows the heating of the channel due to the friction generated by the high-pressure flow inside

    Supersymmetric Mean-Field Theory of t-J Model

    Full text link
    The supersymmetric formulation of t-J model is studied in this paper at the mean-field level where ÎŽ\delta-T phase diagram is computed. We find that slave-fermion-like spiral phase is stable at low doping concentration, and the slave-boson-like d-wave fermionic spin pairing state becomes energetically favourable when Ύ≄\delta\geq 0.23. An improvement in free energy using Gutzwiller's method lowers the transition doping concentration to 0.06. We also point out the existence of new branches of excitations in the supersymmetric theory.Comment: 11 pages and 2 figure
    • 

    corecore