196 research outputs found

    Application of Magneto-Rheological Fluids for Investigating the Effect of Skin Properties on Arterial Tonometry Measurements

    Get PDF
    Accurate, non-invasive measurements of blood pressure and its continuous monitoring are extremely important for personal health care. Arterial tonometry, a method that is used to provide a detailed image of a patient's cardiovascular health, shows promise for being a non-invasive alternative to current blood pressure measurement methods. However, its measurement accuracy is sensitive to patient variations such as the stiffness of the skin. Thus, this project intends to investigate the effect of skin properties (i.e., stiffness) on the accuracy of tonometric blood pressure measurements. To this end, a test platform, consisting of a pulsatile system and a tunable skin stiffness apparatus (or MR apparatus), is constructed. The cam-follower pulsatile system built based on in vivo testing of human pulses is used to generate realistic pulse waveforms. The MR apparatus is able to adjust its stiffness using Magneto-Rheological (MR) fluid whose apparent viscosity changes with applied magnetic fields. Placed at the surface of the MR apparatus, a cylinder with a frictionless plunger simulates a variable applanation force or “hold-down pressure” of tonometry by adjusting the added weights atop the cylinder. Using this test setup, a series of tests were performed by varying the input magnetic field and the weights, which effectively adjusts the skin stiffness and the hold-down pressure, respectively. The vertical displacement of the plunger caused by the internal pulse pressure was measured using a laser displacement sensor. The output displacement waveforms were analyzed with the focus on the peak amplitude difference of the waveforms, which is related to the augmentation index (a surrogate measure of arterial stiffness). The results show that there exists an “optimal” plunger weight or “hold-down pressure” that provides the most distinct output pulse waveforms. The results further show that the difference in the first two peak values decreases as the skin stiffness increases, indicating that the stiffer the skin property, the less the “hold-down pressure” effects on the accuracy of the tonometry measurements

    EFFECTS OF LIQUID SWIRLING ON GAS-TO-LIQUID MASS TRANSFER IN THREE-PHASE FLUIDIZED BEDS

    Get PDF
    The swirling flow mode of liquid phase was adopted to promote the gas-to-liquid mass transfer in three-phase(gas-liquid-solid) fluidized beds. Effects of gas(0.01-0.09m/s) and liquid(0.035-0.172m/s) velocities, particle size(1.7-6.0mm) and swirling ratio of liquid phase(0-0.5) on the volumetric gas-to-liquid mass transfer coefficient in the bed were examined. The mass transfer coefficient increased up to 70% by adjusting the swirling flow of liquid phase, especially when the gas velocity is relatively low range. The value of gas-to-liquid mass transfer coefficient was well correlated in terms of dimensionless groups which were derived from the dimensional analysis on the mass transfer system

    The Etiology and Treatment of the Softened Phallus after the Radial Forearm Osteocutaneous Free Flap Phalloplasty

    Get PDF
    BackgroundThe radial forearm osteocutaneous free flap is considered to be the standard technique for penile construction. One year after their operation, most patients experience a softened phallus, so that they suffer from difficulties in sexual intercourse. In this report, we present our experience with phalloplasty by radial forearm osteocutaneous free flap, as well as an evaluation of the etiology and treatment of the softened phallus.MethodsBetween March 2005 and February 2010, 58 patients underwent phalloplasty by radial forearm osteocutaneous free flap. Most of their neophallus had been softened subjectively and among them, 12 patients who wanted correction were investigated. We performed repetitive fat injection, artificial dermis grafting, silicone rod insertion, and rib bone with cartilaginous tip graft. Physical examination, plain radiograph, computed tomography, bone scintigraphy, and satisfaction scores were investigated.ResultsMost of the participants' penises have been softened after phalloplasty, and the skin elasticity had been also decreased. On plain radiograph, the distal end of the bone was self-rounded; however, the bone shape of the neophallus had no significant interval changes or resorption. Computed tomography showed equivocal density of cortical bone. On bone scintigraphy, the bone metabolism was active at 3 months postoperatively, and remained active 9 years postoperatively.ConclusionsThe use of a rib bone with cartilaginous tip graft could be an option for improvement of the softened phallus. Silicon rod insertion is also worth considering for rigidity of the softened phallus. Decreased rigidity due to soft tissue atrophy could be alleviated with repeated fat injection and artificial dermis grafting

    Letter to the Editor: Detection of EML4-ALK and Other ALK Fusion Genes in Lung Cancer: A Lesson from the Leukemia Fusion Gene Analysis and Future Application

    Get PDF
    We read with interest the article “EML4-ALK Fusion Gene in Korean Non-Small Cell Lung Cancer ” in a recent issue of the Journal of Korean Medical Science by Jin et al. (1). In this study, EML4-ALK fusion gene was detected in 10 of 167 non-small cell lung cancer (NSCLC) patients by using reverse transcriptase-polymerase chain reaction (RT-PCR) as a basic screening technique instead of fluorescence in situ hybridization (FISH) method. The frequency of EML4-ALK fusion gene in this study (6.0%) was not largely different from a previous study that used the FISH method on Korean NSCLC patients (4.2%) (2), while it did not diverge from the results in previous studies on a general NSCLC patient population that yielded 3%-7 % ratios as well. Based on the experience of detecting leukemia fusion genes with several new molecular methods during the diagnosis of leukemia (3-6), we would like to mention the pros and cons of such methods i

    Immunogenicity and Safety of Trivalent Inactivated Influenza Vaccine: A Randomized, Double-Blind, Multi-Center, Phase 3 Clinical Trial in a Vaccine-Limited Country

    Get PDF
    Influenza vaccines are the primary method for controlling influenza and its complications. This study was conducted as a phase 3, randomized, double-blind, controlled, multi-center trial at seven university hospitals to evaluate the immunogenicity and safety of an inactivated, split, trivalent influenza vaccine (GC501, Green Cross Corporation, Yongin, Korea), which was newly manufactured in Korea in 2008. Between September 21 and 26, a total of 329 healthy subjects were recruited for the immunogenicity analysis, while 976 subjects were enrolled for the safety analysis. The GC501 vaccine met both FDA and EMEA criteria with ≥ 80% of subjects achieving post-vaccination titers ≥ 40 for all three subtypes, even in the elderly. The vaccine was well tolerated with only mild systemic and local adverse events. In summary, GC501 showed excellent immunogenicity and a good safety profile in both young adults and the elderly. The licensure of GC501 might be an important basis in preparation for the future influenza pandemic

    Detection of Sentinel Lymph Nodes in patients with Early Stage Cervical Cancer

    Get PDF
    The purpose of this study was to determine the feasibility of identifying the sentinel lymph nodes (SNs) as well as to evaluate factors that might influence the SN detection rate in patients with cervical cancer of the uterus. Eighty nine patients underwent intracervical injection of 1% isosulfan blue dye at the time of planned radical hysterectomy and lymphadenectomy between January 2003 and December 2003. With the visual detection of lymph nodes that stained blue, SNs were identified and removed separately. Then all patients underwent complete pelvic lymph node dissection and/or para-aortic lymph node dissection. SNs were identified in 51 of 89 (57.3%) patients. The most common site for SN detection was the external iliac area. Metastatic nodes were detected in 21 of 89 (23.5%) patients. One false negative SN was obtained. Successful SN detection was more likely in patients younger than 50 yr (p=0.02) and with a history of preoperative conization (p=0.05). However, stage, histological type, surgical procedure and neoadjuvant chemotherapy showed no significant difference for SN detection rate. Therefore, the identification of SNs with isosulfan blue dye is feasible and safe. The SN detection rate was high in patients younger than 50 yr or with a history of preoperative conization
    • …
    corecore