56,762 research outputs found

    Transform-limited X-ray pulse generation from a high-brightness self-amplified spontaneous-emission free-electron laser

    Get PDF
    A method to achieve high-brightness self-amplified spontaneous emission (HB-SASE) in the free-electron laser (FEL) is described. The method uses repeated nonequal electron beam delays to delocalize the collective FEL interaction and break the radiation coherence length dependence on the FEL cooperation length. The method requires no external seeding or photon optics and so is applicable at any wavelength or repetition rate. It is demonstrated, using linear theory and numerical simulations, that the radiation coherence length can be increased by approximately 2 orders of magnitude over SASE with a corresponding increase in spectral brightness. Examples are shown of HB-SASE generating transform-limited FEL pulses in the soft x-ray and near transform-limited pulses in the hard x-ray. Such pulses may greatly benefit existing applications and may also open up new areas of scientific research

    Stability of the proton-to-electron mass ratio

    Full text link
    We report a limit on the fractional temporal variation of the proton-to-electron mass ratio as, obtained by comparing the frequency of a rovibrational transition in SF6 with the fundamental hyperfine transition in Cs. The SF6 transition was accessed using a CO2 laser to interrogate spatial 2-photon Ramsey fringes. The atomic transition was accessed using a primary standard controlled with a Cs fountain. This result is direct and model-free

    A Study of Wavelength Calibration of NEWSIPS High-Dispersion Spectra

    Full text link
    In this study we cross-correlate many IUE echellograms of a variety of stars to evaluate systematic error sources in the wavelength zeropoint of all three cameras. We first evaluated differences between the final archived ("NEWSIPS") and the originally processed ("IUESIPS") spectra. These show a clear time dependence in zeropoint for the SWP camera due to revisions in the IUESIPS wavelength scale. Small IUESIPS - NEWSIPS differences are also found for the LWR camera. We also examined wavelength zeropoint disparities between data obtained both through the small and large entrance apertures and for observations made by different target acquisition modes for faint and bright stars. We found that velocities resulting from these alternative observing modes are nil. For large-aperture observations the dominant error source is the target position placement in the aperture. We searched for spurious trends with time, and found only a suggestion of time trends for faint stars observed with the SWP camera. We also discovered 1-day, +/-3 km/s sinusoidsal patterns in intensive monitoring data which are ascribable to changes in telescope focus resulting from thermal drifts. In the second part of the paper, we measured mean zeropoint errors of NEWSIPS echellogram data against laboratory results by using the GHRS spectral atlas of the 10 Lac. We find that the derived apparent velocity difference for this star is -1 +/-3.5 km/s. Several less precise comparisons lead to similar results. The zeropoints of the NEWSIPS-processed LWP/LWR cameras are evaluated and are also found to be nearly zero (+/-5 km/s) relative to HST atlases of Arcturus and Procyon atlas. These results do not support result by Gonzalez-Riestra et al. that corrections should be introduced to the wavelength scales of various NEWSIPS high-dispersion data products.Comment: 16 pages, Latex with 12 figures, Accepted by Pub. Astron. Soc. Pacific for July 1, 2001. Files available from ftp://nobel.stsci.edu/pub/iuerv

    Non-linear effect of uniaxial pressure on superconductivity in CeCoIn5

    Full text link
    We study single-crystal CeCoIn5 with uniaxial pressure up to 3.97 kbar applied along the c-axis. We find a non-linear dependence of the superconducting transition temperature Tc on pressure, with a maximum close to 2 kbar. The transition also broadens significantly as pressure increases. We discuss the temperature dependence in terms of the general trend that Tc decreases in anisotropic heavy-fermion compounds as they move towards three-dimensional behavior.Comment: 6 pages, 4 figure

    General Relativistic Contributions in Transformation Optics

    Full text link
    One potentially realistic specification for devices designed with transformation optics is that they operate with high precision in curved space-time, such as Earth orbit. This raises the question of what, if any, role does space-time curvature play in determining transformation media? Transformation optics has been based on a three-vector representation of Maxwell's equations in flat Minkowski space-time. I discuss a completely covariant, manifestly four-dimensional approach that enables transformations in arbitrary space-times, and demonstrate this approach for stable circular orbits in the spherically symmetric Schwarzschild geometry. Finally, I estimate the magnitude of curvature induced contributions to satellite-borne transformation media in Earth orbit and comment on the level of precision required for metamaterial fabrication before such contributions become important.Comment: 14 pages, 3 figures. Latest version has expanded analysis, corresponds to published versio

    On network modeling of manufacturing and related processes using GERT Summary report

    Get PDF
    Network modeling of manufacturing and related processes using Graphical Evaluation and Review Techniqu

    False-negative upper extremity ultrasound in the initial evaluation of patients with suspected subclavian vein thrombosis due to thoracic outlet syndrome (Paget-Schroetter syndrome)

    Get PDF
    OBJECTIVE: To assess the utilization and consequences of upper extremity Duplex ultrasound in the initial diagnostic evaluation of patients with suspected subclavian vein (SCV) thrombosis and venous thoracic outlet syndrome (VTOS). METHODS: A retrospective single-center review was conducted for patients that underwent primary surgical treatment for VTOS between 2008 and 2017, in whom an upper extremity ultrasound had been performed as the initial diagnostic test (n = 214). Clinical and treatment characteristics were compared between patients with positive and false-negative ultrasound studies. RESULTS: There were 122 men (57%) and 92 women (43%) that had presented with spontaneous idiopathic arm swelling, including 28 (13%) with proven pulmonary embolism, at a mean age of 30.7 ± 0.8 years (range 14-69). Upper extremity ultrasound had been performed 23.8 ± 12.2 days after the onset of symptoms, with confirmation of axillary-SCV thrombosis in 169 patients (79%) and negative results in 45 (21%). Of the false-negative ultrasound study reports, only 8 (18%) acknowledged limitations in visualizing the central SCV. Definitive diagnostic imaging (DDI) had been obtained by upper extremity venography in 175 (82%), computed tomography angiography in 24 (11%), and magnetic resonance angiography in 15 (7%), with 142 (66%) undergoing catheter-directed axillary-SCV thrombolysis. The mean interval between initial ultrasound and DDI was 48.9 ± 14.2 days with no significant difference between groups, but patients with a positive ultrasound were more likely to have DDI within 48 hours than those with a false-negative ultrasound (44% vs 24%; P = .02). At the time of surgical treatment, the SCV was widely patent following paraclavicular decompression and external venolysis alone in 74 patients (35%). Patch angioplasty was performed for focal SCV stenosis in 76 (36%) and bypass graft reconstruction for long-segment axillary-SCV occlusion in 63 (29%). Patients with false-negative initial ultrasound studies were significantly more likely to require SCV bypass reconstruction than those with a positive ultrasound (44% vs 25%; P = .02). CONCLUSIONS: Duplex ultrasound has significant limitations in the initial evaluation of patients with suspected SCV thrombosis, with false-negative results in 21% of patients with proven VTOS. This is rarely acknowledged in ultrasound reports, but false-negative ultrasound studies have the potential to delay definitive imaging, thrombolysis, and further treatment for VTOS. Initial false-negative ultrasound results are associated with progressive thrombus extension and a more frequent need for SCV bypass reconstruction at the time of surgical treatment

    DiFX2: A more flexible, efficient, robust and powerful software correlator

    Get PDF
    Software correlation, where a correlation algorithm written in a high-level language such as C++ is run on commodity computer hardware, has become increasingly attractive for small to medium sized and/or bandwidth constrained radio interferometers. In particular, many long baseline arrays (which typically have fewer than 20 elements and are restricted in observing bandwidth by costly recording hardware and media) have utilized software correlators for rapid, cost-effective correlator upgrades to allow compatibility with new, wider bandwidth recording systems and improve correlator flexibility. The DiFX correlator, made publicly available in 2007, has been a popular choice in such upgrades and is now used for production correlation by a number of observatories and research groups worldwide. Here we describe the evolution in the capabilities of the DiFX correlator over the past three years, including a number of new capabilities, substantial performance improvements, and a large amount of supporting infrastructure to ease use of the code. New capabilities include the ability to correlate a large number of phase centers in a single correlation pass, the extraction of phase calibration tones, correlation of disparate but overlapping sub-bands, the production of rapidly sampled filterbank and kurtosis data at minimal cost, and many more. The latest version of the code is at least 15% faster than the original, and in certain situations many times this value. Finally, we also present detailed test results validating the correctness of the new code.Comment: 28 pages, 9 figures, accepted for publication in PAS
    • …
    corecore