29 research outputs found

    Design, Performance and Calibration of the CMS Forward Calorimeter Wedges

    Get PDF
    We report on the test beam results and calibration methods using charged particles of the CMS Forward Calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3\l |\eta| \le 5), and is essential for large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h \approx 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form as a/\sqrt{E} + b. The stochastic term a is 198% and the constant term b is 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%

    Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter

    Get PDF
    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS

    Bibliometric analysis of publications on house dust mites during 1980-2018

    No full text
    Ozkan, Aysegul Taylan/0000-0001-8421-3625; AKMESE, Omer Faruk/0000-0002-5877-0177WOS:000546977100010PubMed: 32284264Background: The global prevalence of allergic diseases has increased dramatically in recent years and are now recognized as significant chronic diseases worldwide. One of the most important allergens that causes allergic diseases is house dust mites. Objective: This study aims to present a bibliometric overview of research published on dust mites between 1980 and 2018. Methods: Articles published from 1980 to 2018 were analyzed using bibliometric methods. The keywords ?Dust mite*,? and ? Dermatophagoides ? were used in the Web of Science (WoS). Simple linear regression analysis was used to estimate the number of future publications on this subject. Results: A total of 4742 publications were found, 2552 (53.8%) of them were articles. Most of the articles were on subjects related to immunology (1274; 49.9%) and allergy (1229; 48.1%). Clinical and Experimental Allergy (222; 8.7%) was the journal with the most publications. The USA was the country that most contributed to the literature with 461 (18.1%) articles. The countries producing the most publications on this subject were developed countries. The most active author was W.R. Thomas (66; 2.5%). The most productive institution was the University of Western Australia (91; 3.6%). The most cited article was published in the New England Journal of Medicine .Conclusion: According to the findings, developed countries were the most productive in publishing on house dust mites. By planning multinational research rather than regional studies, it may be suggested that researchers in underdeveloped or developing countries could also-conduct more research on this subject.(C) 2019 SEICAP. Published by Elsevier Espana, S.L.U. All rights reserved

    Intravitreal injection of methotrexate in an experimental rabbit model: Determination of ultrastructural changes

    No full text
    Purpose: To investigate the ultrastructural changes of the rabbit retina induced by intravitreal methotrexate injection. Materials and Methods: Ten New Zealand white rabbits were enucleated bilaterally at different time periods after intravitreal methotrexate injection. One rabbit was used as control group and one rabbit was used as intact group. Histopathological examinations were performed under light and electron microscopy. Early (within first three days after injection) and long-term (one month after serial injections) effects of intravitreal methotrexate on the retina were investigated. Results: Retinal edema, vacuolization, and disintegration of mitochondria of the retinal cells were observed as early changes. The main long-term effects after serial injections were edema in the photoreceptor, inner nuclear, and ganglionic cell layers. Cellular disorganisation was seen on light microscopy. Electron microscopic examination revealed mitochondrial degeneration and vacuole formation in retinal cells, nuclear degeneration in outer nuclear layer, and membranous whorl formation in photoreceptor and nerve fiber layers. Conclusions High dose intravitreal methotrexate injection may cause significant ultrastructural changes in the rabbit retina in varying severity. This finding may highlight the potential side effects of methotrexate on human retina in higher doses
    corecore