364 research outputs found

    Reduced Self-Perception of Fatigue after Intake of Panax ginseng Root Extract (G115®) Formulated with Vitamins and Minerals An Open-Label Study

    Get PDF
    Background: Unexplained fatigue is a common complaint. When underlying disease causes have been eliminated, lifestyle measures and supplementation can be indicated. Elaborating on clinical findings that G115®, a dry extract from the root of Panax ginseng, combined with vitamins and minerals could alleviate fatigue, this open label study aimed at assessing its effect on perceived fatigue and energy. Methods: Healthy adults self-reporting fatigue (n = 103) completed the Multidimensional Fatigue Inventory questionnaire. They rated their perceptions of mental and physical fatigue, energy, performance, and stress at baseline and 15, 30, 60 and 90 days after a daily intake of 40 mg G115® formulated with vitamins and minerals. Results: Compared with baseline values, mean self-perception of general fatigue was reduced by −7.55 units [95% CI: −8.44; −6.66] (−41.8%, p < 0.0001) at 90 days. All assessed perception ratings (mental and physical fatigue, reduced activity and motivation, performance, and stress) were significantly and steadily improved from two weeks after supplementation up to study's end. Overall satisfaction with the ability of the product to reduce fatigue reached 85% at Day 90. Conclusion: Daily intake with G115® extract formulated with vitamins and minerals suggests an improvement of self-perception of fatigue and energy in a fatigued adult population

    Helix straminea Briganti, 1825 in Italy (Gastropoda: Pulmonata): taxonomic history, morphology, biology, distribution and phylogeny

    Get PDF
    The land snail taxon Helix straminea Briganti, 1825 has been reintroduced as a valid species in 2014. We provide here a comprehensive account of its taxonomy, distribution, anatomy, phylogeny and karyology in Italy. An overview of the historical views on the validity of the species is presented and faunistic data are reviewed and implemented with new records from Campania and Basilicata. A lectotype is fixed for H. straminea from the syntypes stored in the Muséum d'Histoire Naturelle of Genève, as well as for three other taxa (Helix straminiformis Bourguignat, 1876, Helix yleobia Bourguignat, 1883 and Helix straminea ssp. elongata Bourguignat, 1860). Genital system, radula and karyotype are described for the first time. Molecular analysis of two mitochondrial genes combining GenBank data and the new sequences presented in this paper showed no differentiation between the northern and southern Italian populations. The conservation status of the species and its possible threats are discussed

    Helix straminea Briganti, 1825 in Italy (Gastropoda: Pulmonata): taxonomic history, morphology, biology, distribution and phylogeny

    Get PDF
    The land snail taxon Helix straminea Briganti, 1825 has been reintroduced as a valid species in 2014. We provide here a comprehensive account of its taxonomy, distribution, anatomy, phylogeny and karyology in Italy. An overview of the historical views on the validity of the species is presented and faunistic data are reviewed and implemented with new records from Campania and Basilicata. A lectotype is fixed for H. straminea from the syntypes stored in the Muséum d’Histoire Naturelle of Genève, as well as for three other taxa (Helix straminiformis Bourguignat, 1876, Helix yleobia Bourguignat, 1883 and Helix straminea ssp. elongata Bourguignat, 1860). Genital system, radula and karyotype are described for the first time. Molecular analysis of two mitochondrial genes combining GenBank data and the new sequences presented in this paper showed no differentiation between the northern and southern Italian populations. The conservation status of the species and its possible threats are discussed

    The CMS conductor

    Get PDF
    The Compact Muon Solenoid (CMS) is one of the experiments, which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN, the design field of the CMS magnet is 4 T, the magnetic length is 13 m and the aperture is 6 m. This high magnetic field is achieved by means of a 4 layer, 5 modules superconducting coil. The coil is wound from an Al-stabilized Rutherford type conductor. The nominal current of the magnet is 20 kA at 4.5 K. In the CMS coil the structural function is ensured, unlike in other existing Al-stabilized thin solenoids, both by the Al-alloy reinforced conductor and the external former. In this paper the retained manufacturing process of the 50-km long reinforced conductor is described. In general the Rutherford type cable is surrounded by high purity aluminium in a continuous co-extrusion process to produce the Insert. Thereafter the reinforcement is joined by Electron Beam Welding to the pure Al of the insert, before being machined to the final dimensions. During the manufacture the bond quality between the Rutherford cable and the high purity aluminium as well as the quality of the EB welding are continuously controlled by a novel ultrasonic phased array system. The dimensions of the insert and the final conductor are measured by laser micrometer. (8 refs)

    Hidden expectations: Scaffolding subject specialists' genre knowledge of the assignments they set

    Get PDF
    Subject specialists’ knowledge of academic and disciplinary literacy is often tacit. We tackle the issue of how to elicit subject specialists’ tacit knowledge in order to develop their pedagogical practices and enable them to communicate this knowledge to students. Drawing on theories of genre and metacognition, a professional development activity was designed and delivered. Our aims were to (1) build participants’ genre knowledge and (2) scaffold metacognitive awareness of how genre knowledge can enhance their pedagogical practices. The findings reveal that participants built a genre-based understanding of academic literacy and that the tasks provided them with an accessible framework to articulate and reflect upon their knowledge of disciplinary literacy. Participants gained metacognitive awareness of misalignments between what they teach and what they expect from students, their assumptions about students’ prior learning and genre-based strategies to adapt their practice to students’ needs. Our approach provides a theoretically grounded professional development tool for the HE sector

    Novel contrast-enhanced ultrasound imaging in prostate cancer

    Get PDF
    The purposes of this paper were to present the current status of contrast-enhanced transrectal ultrasound imaging and to discuss the latest achievements and techniques now under preclinical testing. Although grayscale transrectal ultrasound is the standard method for prostate imaging, it lacks accuracy in the detection and localization of prostate cancer. With the introduction of contrast-enhanced ultrasound (CEUS), perfusion imaging of the microvascularization became available. By this, cancer-induced neovascularisation can be visualized with the potential to improve ultrasound imaging for prostate cancer detection and localization significantly. For example, several studies have shown that CEUS-guided biopsies have the same or higher PCa detection rate compared with systematic biopsies with less biopsies needed. This paper describes the current status of CEUS and discusses novel quantification techniques that can improve the accuracy even further. Furthermore, quantification might decrease the user-dependency, opening the door to use in the routine clinical environment. A new generation of targeted microbubbles is now under pre-clinical testing and showed avidly binding to VEGFR-2, a receptor up-regulated in prostate cancer due to angiogenesis. The first publications regarding a targeted microbubble ready for human use will be discussed. Ultrasound-assisted drug delivery gives rise to a whole new set of therapeutic options, also for prostate cancer. A major breakthrough in the future can be expected from the clinical use of targeted microbubbles for drug delivery for prostate cancer diagnosis as well as treatmen

    Production of Multiple Brain-Like Ganglioside Species Is Dispensable for Fas-Induced Apoptosis of Lymphoid Cells

    Get PDF
    Activation of an acid sphingomyelinase (aSMase) leading to a biosynthesis of GD3 disialoganglioside has been associated with Fas-induced apoptosis of lymphoid cells. The present study was undertaken to clarify the role of this enzyme in the generation of gangliosides during apoptosis triggered by Fas ligation. The issue was addressed by using aSMase-deficient and aSMase-corrected cell lines derived from Niemann-Pick disease (NPD) patients. Fas cross-linking elicited a rapid production of large amounts of complex a- and b-series species of gangliosides with a pattern and a chromatographic behavior as single bands reminiscent of brain gangliosides. The gangliosides were synthesized within the first ten minutes and completely disappeared within thirty minutes after stimulation. Noteworthy is the observation that GD3 was not the only ganglioside produced. The production of gangliosides and the onset of apoptotic hallmarks occurred similarly in both aSMase-deficient and aSMase-corrected NPD lymphoid cells, indicating that aSMase activation is not accountable for ganglioside generation. Hampering ganglioside production by inhibiting the key enzyme glucosylceramide synthase did not abrogate the apoptotic process. In addition, GM3 synthase-deficient lymphoid cells underwent Fas-induced apoptosis, suggesting that gangliosides are unlikely to play an indispensable role in transducing Fas-induced apoptosis of lymphoid cells

    Identification of biomolecule mass transport and binding rate parameters in living cells by inverse modeling

    Get PDF
    BACKGROUND: Quantification of in-vivo biomolecule mass transport and reaction rate parameters from experimental data obtained by Fluorescence Recovery after Photobleaching (FRAP) is becoming more important. METHODS AND RESULTS: The Osborne-Moré extended version of the Levenberg-Marquardt optimization algorithm was coupled with the experimental data obtained by the Fluorescence Recovery after Photobleaching (FRAP) protocol, and the numerical solution of a set of two partial differential equations governing macromolecule mass transport and reaction in living cells, to inversely estimate optimized values of the molecular diffusion coefficient and binding rate parameters of GFP-tagged glucocorticoid receptor. The results indicate that the FRAP protocol provides enough information to estimate one parameter uniquely using a nonlinear optimization technique. Coupling FRAP experimental data with the inverse modeling strategy, one can also uniquely estimate the individual values of the binding rate coefficients if the molecular diffusion coefficient is known. One can also simultaneously estimate the dissociation rate parameter and molecular diffusion coefficient given the pseudo-association rate parameter is known. However, the protocol provides insufficient information for unique simultaneous estimation of three parameters (diffusion coefficient and binding rate parameters) owing to the high intercorrelation between the molecular diffusion coefficient and pseudo-association rate parameter. Attempts to estimate macromolecule mass transport and binding rate parameters simultaneously from FRAP data result in misleading conclusions regarding concentrations of free macromolecule and bound complex inside the cell, average binding time per vacant site, average time for diffusion of macromolecules from one site to the next, and slow or rapid mobility of biomolecules in cells. CONCLUSION: To obtain unique values for molecular diffusion coefficient and binding rate parameters from FRAP data, we propose conducting two FRAP experiments on the same class of macromolecule and cell. One experiment should be used to measure the molecular diffusion coefficient independently of binding in an effective diffusion regime and the other should be conducted in a reaction dominant or reaction-diffusion regime to quantify binding rate parameters. The method described in this paper is likely to be widely used to estimate in-vivo biomolecule mass transport and binding rate parameters

    Sensitivity of Five Rapid HIV Tests on Oral Fluid or Finger-Stick Whole Blood: A Real-Time Comparison in a Healthcare Setting

    Get PDF
    BACKGROUND: Health authorities in several countries recently recommended the expansion of human immunodeficiency virus (HIV) antibody testing, including the use of rapid tests. Several HIV rapid tests are now licensed in Europe but their sensitivity on total blood and/or oral fluid in routine healthcare settings is not known. METHODS AND FINDINGS: 200 adults with documented HIV-1 (n=194) or HIV-2 infection (n=6) were prospectively screened with five HIV rapid tests using either oral fluid (OF) or finger-stick whole blood (FSB). The OraQuick Advance rapid HIV1/2 was first applied to OF and then to FSB, while the other tests were applied to FSB, in the following order: Vikia HIV 1/2, Determine HIV 1-2, Determine HIV-1/2 Ag/Ab Combo and INSTI HIV-1/HIV-2. Tests negative on FSB were repeated on paired serum samples. Twenty randomly selected HIV-seronegative subjects served as controls, and the results were read blindly. Most patients had HIV-1 subtype B infection (63.3%) and most were on antiretroviral therapy (68.5%). Sensitivity was 86.5%, 94.5%, 98.5%, 94.9%, 95.8% and 99% respectively, with OraQuick OF, OraQuick FSB, Vikia, Determine, Determine Ag/Ab Combo and INSTI (p<0.0001). OraQuick was less sensitive on OF than on FSB (p=0.008). Among the six patients with three or more negative tests, two had recent HIV infection and four patients on antiretroviral therapy had undetectable plasma viral load. When patients positive in all the tests were compared with patients who had at least one negative test, only a plasma HIV RNA level<200 cp/ml was significantly associated with a false-negative result (p=0.009). When the 33 rapid tests negative on FSB were repeated on serum, all but six (5 negative with OraQuick, 1 with INSTI) were positive. The sensitivity of OraQuick, Determine and Determine Ag/Ab Combo was significantly better on serum than on FSB (97.5%, p=0.04; 100%, p=0.004; and 100%, p=0.02, respectively). CONCLUSION: When evaluated in a healthcare setting, rapid HIV tests were less sensitive on oral fluid than on finger-stick whole blood and less sensitive on finger-stick whole blood than on serum
    corecore