1,038 research outputs found

    Introduction

    Get PDF

    Contrasting the beam interaction characteristics of selected lasers with a partially stabilised zirconia (PSZ) bio-ceramic

    Get PDF
    Differences in the beam interaction characteristics of a CO2 laser, a Nd:YAG laser, a high power diode laser (HPDL) and an excimer laser with a partially stabilised zirconia (PSZ) bio-ceramic have been studied. A derivative of Beer-Lambert’s law was applied and the laser beam absorption lengths of the four lasers were calculated as 33.55 x 10-3 cm for the CO2 laser, 18.22 x 10-3 cm for the Nd:YAG laser, 17.17 x 10-3 cm for the HPDL and 8.41 x 10-6 cm for the excimer laser. It was determined graphically that the fluence threshold values at which significant material removal was effected by the CO2 laser, the Nd:YAG laser, the HPDL and the excimer laser were 52 J/cm2, 97 J/cm2, 115 J/cm2 and 0.48 J/cm2 respectively. The thermal loading value for the CO2 laser, the Nd:YAG laser, the HPDL and the excimer laser were calculated as being 1.55 kJ/cm3, 5.32 kJ/cm3, 6.69 kJ/cm3 and 57.04 kJ/cm3 respectively

    Wettability characteristics of an Al2O3/SiO2-based ceramic modified with CO2, Nd:YAG, excimer and high-power diode lasers

    Get PDF
    Interaction of CO2, Nd:YAG, excimer and high power diode laser (HPDL) radiation with the surface of an Al2O3/SiO2 based ceramic was found to effect significant changes in the wettability characteristics of the material. It was observed that interaction with CO2, Nd:YAG and HPDL radiation reduced the enamel contact angle from 1180 to 310, 340 and 330 respectively. In contrast, interaction with excimer laser radiation resulted an increase in the contact angle to 1210. Such changes were identified as being due to: (i) the melting and partial vitrification of the Al2O3/SiO2 based ceramic surface as a result of interaction with CO2, Nd:YAG HPDL radiation. (ii) the surface roughness of the Al2O3/SiO2 based ceramic increasing after interaction with excimer laser radiation. (iii) the surface oxygen content of the Al2O3/SiO2 based ceramic increasing after interaction with CO2, Nd:YAG and HPDL radiation. The work has shown that the wettability characteristics of the Al2O3/SiO2 based ceramic could be controlled and/or modified with laser surface treatment. In particular, whether the laser radiation had the propensity to cause surface melting. However, a wavelength dependance of the change of the wetting properties could not be deduced from the findings of this work

    One-Year Risk of Stroke after Transient Ischemic Attack or Minor Stroke

    Get PDF
    BACKGROUND Previous studies conducted between 1997 and 2003 estimated that the risk of stroke or an acute coronary syndrome was 12 to 20% during the first 3 months after a transient ischemic attack (TIA) or minor stroke. The TIAregistry.org project was designed to describe the contemporary profile, etiologic factors, and outcomes in patients with a TIA or minor ischemic stroke who receive care in health systems that now offer urgent evaluation by stroke specialists. METHODS We recruited patients who had had a TIA or minor stroke within the previous 7 days. Sites were selected if they had systems dedicated to urgent evaluation of patients with TIA. We estimated the 1-year risk of stroke and of the composite outcome of stroke, an acute coronary syndrome, or death from cardiovascular causes. We also examined the association of the ABCD2 score for the risk of stroke (range, 0 [lowest risk] to 7 [highest risk]), findings on brain imaging, and cause of TIA or minor stroke with the risk of recurrent stroke over a period of 1 year. RESULTS From 2009 through 2011, we enrolled 4789 patients at 61 sites in 21 countries. A total of 78.4% of the patients were evaluated by stroke specialists within 24 hours after symptom onset. A total of 33.4% of the patients had an acute brain infarction, 23.2% had at least one extracranial or intracranial stenosis of 50% or more, and 10.4% had atrial fibrillation. The Kaplan–Meier estimate of the 1-year event rate of the composite cardiovascular outcome was 6.2% (95% confidence interval, 5.5 to 7.0). Kaplan–Meier estimates of the stroke rate at days 2, 7, 30, 90, and 365 were 1.5%, 2.1%, 2.8%, 3.7%, and 5.1%, respectively. In multivariable analyses, multiple infarctions on brain imaging, large-artery atherosclerosis, and an ABCD2 score of 6 or 7 were each associated with more than a doubling of the risk of stroke. CONCLUSIONS We observed a lower risk of cardiovascular events after TIA than previously reported. The ABCD2 score, findings on brain imaging, and status with respect to large-artery atherosclerosis helped stratify the risk of recurrent stroke within 1 year after a TIA or minor stroke. (Funded by Sanofi and Bristol-Myers Squibb.)Supported by an unrestricted grant from Sanofi and Bristol-Myers Squibb

    One More Awareness Gap? The Behaviour–Impact Gap Problem

    Get PDF
    Preceding research has made hardly any attempt to measure the ecological impacts of pro-environmental behaviour in an objective way. Those impacts were rather supposed or calculated. The research described herein scrutinized the ecological impact reductions achieved through pro-environmental behaviour and raised the question how much of a reduction in carbon footprint can be achieved through voluntary action without actually affecting the socio-economic determinants of life. A survey was carried out in order to measure the difference between the ecological footprint of “green” and “brown” consumers. No significant difference was found between the ecological footprints of the two groups—suggesting that individual pro-environmental attitudes and behaviour do not always reduce the environmental impacts of consumption. This finding resulted in the formulation of a new proposition called the BIG (behaviour–impact gap) problem, which is an interesting addition to research in the field of environmental awareness gaps
    • 

    corecore