1,448 research outputs found

    Development of high critical current density in multifilamentary round-wire Bi2Sr2CaCu2O8+x by strong overdoping

    Full text link
    Bi2Sr2CaCu2O8+x is the only cuprate superconductor that can be made into a round-wire conductor form with a high enough critical current density Jc for applications. Here we show that the Jc(5 T,4.2 K) of such Ag-sheathed filamentary wires can be doubled to more than 1.4x10^5 A/cm^2 by low temperature oxygenation. Careful analysis shows that the improved performance is associated with a 12 K reduction in transition temperature Tc to 80 K and a significant enhancement in intergranular connectivity. In spite of the macroscopically untextured nature of the wire, overdoping is highly effective in producing high Jc values.Comment: 4 figure

    Atmospheric conditions and their effect on ball-milled magnesium diboride

    Full text link
    Magnesium diboride bulk pellets were fabricated from pre-reacted MgB2 powder ball milled with different amounts of exposure to air. Evidence of increased electron scattering including increased resistivity, depressed Tc, and enhanced Hc2 of the milled and heat treated samples were observed as a result of increased contact with air. These and other data were consistent with alloying with carbon as a result of exposure to air. A less clear trend of decreased connectivity associated with air exposure was also observed. In making the case that exposure to air should be considered a doping process, these results may explain the wide varibability of "undoped" MgB2 properties extant in the literature.Comment: Work presented at ASC 2006 in Seattl

    Nanoscale grains, high irreversibility field, and large critical current density as a function of high energy ball milling time in C-doped magnesium diboride

    Full text link
    Magnesium diboride (MgB2) powder was mechanically alloyed by high energy ball milling with C to a composition of Mg(B0.95C0.05)2 and then sintered at 1000 C in a hot isostatic press. Milling times varied from 1 minute to 3000 minutes. Full C incorporation required only 30-60 min of milling. Grain size of sintered samples decreased with increased milling time to less than 30 nm for 20-50 hrs of milling. Milling had a weak detrimental effect on connectivity. Strong irreversibility field (H*) increase (from 13.3 T to 17.2 T at 4.2 K) due to increased milling time was observed and correlated linearly with inverse grain size (1/d). As a result, high field Jc benefited greatly from lengthy powder milling. Jc(8 T, 4.2 K) peaked at > 80,000 A/cm2 with 1200 min of milling compared with only ~ 26,000 A/cm2 for 60 min of milling. This non-compositional performance increase is attributed to grain refinement of the unsintered powder by milling, and to the probable suppression of grain growth by milling-induced MgO nano-dispersions.Comment: 12 pages, 11 figure

    The second ESGAR consensus statement on CT colonography

    Get PDF
    To update quality standards for CT colonography based on consensus among opinion leaders within the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). A multinational European panel of nine members of the ESGAR CT colonography Working Group (representing six EU countries) used a modified Delphi process to rate their level of agreement on a variety of statements pertaining to the acquisition, interpretation and implementation of CT colonography. Four Delphi rounds were conducted, each at 2 months interval. The panel elaborated 86 statements. In the final round the panelists achieved complete consensus in 71 of 86 statements (82 %). Categories including the highest proportion of statements with excellent Cronbach's internal reliability were colon distension, scan parameters, use of intravenous contrast agents, general guidelines on patient preparation, role of CAD and lesion measurement. Lower internal reliability was achieved for the use of a rectal tube, spasmolytics, decubitus positioning and number of CT data acquisitions, faecal tagging, 2D vs. 3D reading, and reporting. The recommendations of the consensus should be useful for both the radiologist who is starting a CTC service and for those who have already implemented the technique but whose practice may need updating

    Thermal performance of thermoactive continuous flight auger piles

    Get PDF
    Foundation piles are being increasingly equipped with heat exchangers to efficiently harvest shallow geothermal energy. For buildings in urban areas, continuous flight auger (CFA) piles are common owing to their speed, cost-efficiency and low noise levels. To construct a thermoactive CFA pile usually requires separate central installation of the heat exchanger. However, the energy performance of this type of pile has not been investigated systematically, with most studies focused on rotary piles where the heat exchanger is attached to the reinforcing cage. In this work, insights are provided about the main influences on the energy efficiency of thermoactive CFA piles, with a focus on the implications of using CFA construction techniques rather than rotary boring. An innovative three-dimensional numerical model, able to capture the different aspects of transient heat transfer, is employed together with analytical methods to evaluate the transient and steady-state behaviour of energy piles in a number of design situations. Attention is given to understanding the role of possible pipe-to-pipe interaction, which cannot be systematically investigated with standard methods. Finally, practical guidelines on the optimal choice of design parameters to maximise the energy efficiency of CFA piles, without altering the geotechnical arrangements, are provided

    The second ESGAR consensus statement on CT colonography

    Get PDF
    Objective: To update quality standards for CT colonography based on consensus among opinion leaders within the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). Material and methods: A multinational European panel of nine members of the ESGAR CT colonography Working Group (representing six EU countries) used a modified Delphi process to rate their level of agreement on a variety of statements pertaining to the acquisition, interpretation and implementation of CT colonography. Four Delphi rounds were conducted, each at 2 months interval. Results: The panel elaborated 86 statements. In the final round the panelists achieved complete consensus in 71 of 86 statements (82 %). Categories including the highest proportion of statements with excellent Cronbach's internal reliability were colon distension, scan parameters, use of intravenous contrast agents, general guidelines on patient preparation, role of CAD and lesion measurement. Lower internal reliability was achieved for the use of a rectal tube, spasmolytics, decubitus positioning and number of CT data acquisitions, faecal tagging, 2D vs. 3D reading, and reporting. Conclusion: The recommendations of the consensus should be useful for both the radiologist who is starting a CTC service and for those who have already implemented the technique but whose practice may need updating. Key Points: • Computed tomographic colonography is the optimal radiological method of assessing the colon • This article reviews ESGAR quality standards for CT colonography • This article is aimed to provide CT-colonography guidelines for practising radiologists • The recommendations should help radiologists who are starting/updating their CTC services © 2012 The Author(s)
    corecore