236 research outputs found
Cryogenic Pressure Calibration Facility Using a Cold Force Reference
Presently various commercial cryogenic pressure sensors are being investigated for installation in the LHC collider, they will eventually be used to assess that the magnets are fully immersed in liquid and to monitor fast pressure transients. In the framework of this selection procedure a cryogenic pressue calibration facility has been designed and built; it is based on a cryogenic primary pressure reference made of a bellows that converts the pressure into a force measurement. For that a shaft transfers this force to a precision force transducer at room temperature. Knowing the liquid bath pessure and the surface area of the bellows the pressure applied to the transducers under calibration is calculated; corrections due to thermal contraction are introduced. To avoid loss of force in the bellows wall its length is maintained constant; a cold capacitive displacement sensor measures this. The calibration temperature covers 1.5 K to 4.2 K and the pressure 0 to 20 bar. In contrast with more classical techniques that refer to a pressure reference at room temperature, the method presented in this paper avoid errors due to the uncertainty on the hydrostatic head calculation, to thermoacoustic oscillations and to pressure variation caused by temperature drift along the sensing capillary
Qualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron Collider
The superconducting magnets of the Large Hadron Collider (LHC) will be cooled at 1.9 K by distributed cooling loops working with saturated two-phase superfluid helium flowing in 107 m long bayonet heat exchangers [1] located in each magnet cold-mass cell. The temperature of the magnets could be difficult to control because of the large dynamic heat load variations. Therefore, it is foreseen to measure the heat exchangers pressure to feed the regulation loops with the corresponding saturation temperature. The required uncertainty of the sub-atmospheric saturation pressure measurement shall be of the same order of the one associated to the magnet thermometers, in pressure it translates as ±5 Pa at 1.6 kPa. The transducers shall be radiation hard as they will endure, in the worst case, doses up to 10 kGy and 10**15 neutrons·cm**-2 over 10 years. The sensors under evaluation were installed underground in the dump section of the SPS accelerator with a radiation environment close to the one expected for the LHC. The monitoring equipment was installed in a remote radiation protected area. This paper presents the results of the radiation qualification campaign with emphasis on the reliability and accuracy of the pressure sensors under the test conditions
Instrumentation, Field Network And Process Automation for the LHC Cryogenic Line Tests
This paper describes the cryogenic control system and associated instrumentation of the test facility for 3 pre-series units of the LHC Cryogenic Distribution Line. For each unit, the process automation is based on a Programmable Logic Con-troller implementing more than 30 closed control loops and handling alarms, in-terlocks and overall process management. More than 160 sensors and actuators are distributed over 150 m on a Profibus DP/PA network. Parameterization, cali-bration and diagnosis are remotely available through the bus. Considering the diversity, amount and geographical distribution of the instru-mentation involved, this is a representative approach to the cryogenic control system for CERN's next accelerator
Instrumentation, Field Network and Process Automation for the Cryogenic System of the LHC Test String
CERN is now setting up String 2, a full-size prototype of a regular cell of the LHC arc. It is composed of two quadrupole, six dipole magnets, and a separate cryogenic distribution line (QRL) for the supply and recovery of the cryogen. An electrical feed box (DFB), with up to 38 High Temperature Superconducting (HTS) leads, powers the magnets. About 700 sensors and actuators are distributed along four Profibus DP and two Profibus PA field buses. The process automation is handled by two controllers, running 126 Closed Control Loops (CCL). This paper describes the cryogenic control system, associated instrumentation, and their commissioning
Neutron Irradiation Tests of Pressure Transducers in Liquid Helium
The superconducting magnets of the future Large Hadron Collider (LHC) at CERN will operate in pressurised superfluid helium (1 bar, 1.9 K). About 500 pressure transducers will be placed in the liquid helium bath for monitoring the filling and the pressure transients after resistive transitions. Their precision must remain better than 100 mbar at pressures below 2 bar and better than 5% for higher pressures (up to 20 bar), with temperatures ranging from 1.8 K to 300 K. All the tested transducers are based on the same principle: the fluid or gas is separated from a sealed reference vacuum by an elastic membrane; its deformation indicates the pressure. The transducers will be exposed to high neutron fluence (2 kGy, 1014 n/cm2 per year) during the 20 years of machine operation. This irradiation may induce changes both on the membranes characteristics (leakage, modification of elasticity) and on gauges which measure their deformations. To investigate these effects and select the transducer to be used in the LHC, a neutron irradiation program is being performed at the CERI cyclotron (CNRS Orléans, France): a cryostat is installed on a beam line, transducers are immersed in liquid helium and irradiated by neutrons (1-20 MeV, 1015 n/cm2). The tested transducers measure the helium bath pressure, the true value of which is given by a warm, unirradiated sensor. Every readout is acquired on-line. This paper presents the results of the first experiments performed during spring, 1999
Symptoms after Ingestion of Pig Whipworm Trichuris suis Eggs in a Randomized Placebo-Controlled Double-Blind Clinical Trial
Symptoms after human infection with the helminth Trichuris suis have not previously been described. Exposure to helminths has been suggested as immune therapy against allergy and autoimmune diseases. We randomized adults with allergic rhinitis to ingest a dose of 2500 T. suis eggs or placebo every 21 days for 168 days (total 8 doses) in a double-blind clinical trial. In a previous publication, we reported a lack of efficacy and a high prevalence of adverse gastrointestinal reactions. The aim of the present study was to present a detailed description of the adverse event data and post-hoc analyses of gastrointestinal reactions. Adverse events and severity (mild, moderate, severe) were recorded daily by subjects, classified by organ using MedDRA 10.0, and event rates compared between subjects on T. suis treatment vs. subjects on placebo. T. suis-specific serum IgG antibodies were measured by a fluoroenzymeimmunoassay (Phadia ApS). During 163 days complete follow-up, subjects ingesting T. suis eggs (N = 49) had a three to 19-fold higher rate of events (median duration, 2 days) with gastrointestinal reactions (moderate to severe flatulence, diarrhea, and upper abdominal pain) compared with placebo subjects (N = 47). The highest incidence of affected subjects was seen from the first few days and until day 42 (3rd dose): 63% vs. 29% for placebo; day 163: 76% vs. 49% for placebo. Seroprevalences increased concurrently in the T. suis group: Day 59, 50%; day 90, 91%; day 170, 93%. The combined duration of episodes with onset before day 42 was ≤14 days in 80% of affected subjects. Age, gender, total IgE, and recent intestinal symptoms at baseline did not predict gastrointestinal side effects. In conclusion, during the first 2 months, repeated ingestions of 2500 T. suis eggs caused frequent gastrointestinal reactions lasting up to 14 days, whereas 4 months further treatment mainly provoked a subclinical stimulation
A case for taking the dual role of counsellor-researcher in qualitative research
This is an Accepted Manuscript of an article published by Taylor & Francis in Qualitative Research in Psychology on 3rd August 2016, available online: https://doi.org/10.1080/14780887.2016.1205694There is ongoing debate about whether the challenges of practice-based research in counselling, with clients’ discourses providing the raw data, can be overcome. This article begins by considering the argument of whether taking a dual role of counsellor-researcher within case study research is a legitimate qualitative approach. A case example using sand-tray in short-term therapy with adults from a pluralistic perspective is provided to demonstrate how the challenges of the dual role can be managed to produce effective research findings. It is suggested that this approach closes the gap between research and practice to produce findings that are highly relevant to the counselling context. The ethical considerations of taking a dual role of counsellor-researcher are considered, and opportunities and challenges when adopting this approach are identified
Does primary brachial plexus surgery alter palliative tendon transfer surgery outcomes in children with obstetric paralysis?
<p>Abstract</p> <p>Background</p> <p>The surgical management of obstetrical brachial plexus palsy can generally be divided into two groups; early reconstructions in which the plexus or affected nerves are addressed and late or palliative reconstructions in which the residual deformities are addressed. Tendon transfers are the mainstay of palliative surgery. Occasionally, surgeons are required to utilise already denervated and subsequently reinnervated muscles as motors. This study aimed to compare the outcomes of tendon transfers for residual shoulder dysfunction in patients who had undergone early nerve surgery to the outcomes in patients who had not.</p> <p>Methods</p> <p>A total of 91 patients with obstetric paralysis-related shoulder abduction and external rotation deficits who underwent a modified Hoffer transfer of the latissimus dorsi/teres major to the greater tubercle of the humerus tendon between 2002 and 2009 were retrospectively analysed. The patients who had undergone neural surgery during infancy were compared to those who had not in terms of their preoperative and postoperative shoulder abduction and external rotation active ranges of motion.</p> <p>Results</p> <p>In the early surgery groups, only the postoperative external rotation angles showed statistically significant differences (25 degrees and 75 degrees for total and upper type palsies, respectively). Within the palliative surgery-only groups, there were no significant differences between the preoperative and postoperative abduction and external rotation angles. The significant differences between the early surgery groups and the palliative surgery groups with total palsy during the preoperative period diminished postoperatively (p < 0.05 and p > 0.05, respectively) for abduction but not for external rotation. Within the upper type palsy groups, there were no significant differences between the preoperative and postoperative abduction and external rotation angles.</p> <p>Conclusions</p> <p>In this study, it was found that in patients with total paralysis, satisfactory shoulder abduction values can be achieved with tendon transfers regardless of a previous history of neural surgery even if the preoperative values differ.</p
Danish Integrated Antimicrobial Resistance Monitoring and Research Program
This program has led to changes in the use of antimicrobial agents in Denmark and other countries
- …