705 research outputs found
Multiple-point statistical simulation for hydrogeological models: 3D training image development and conditioning strategies
Most studies about the application of geostatistical simulations based on multiple-point statistics (MPS) to hydrogeological modelling focus on relatively fine-scale models and concentrate on the estimation of facies-level, structural uncertainty. Much less attention is paid to the use of input data and optimal construction of training images. For instance, even though the training image should capture a set of spatial geological characteristics to guide the simulations, the majority of the research still relies on 2D or quasi-3D training images. In the present study, we demonstrate a novel strategy for 3D MPS modelling characterized by: (i) realistic 3D training images, and (ii) an effective workflow for incorporating a diverse group of geological and geophysical data sets. The study covers an area of 2810 km2 in the southern part of Denmark. MPS simulations are performed on a subset of the geological succession (the lower to middle Miocene sediments) which is characterized by relatively uniform structures and dominated by sand and clay. The simulated domain is large and each of the geostatistical realizations contains approximately 45 million voxels with size 100 m × 100 m × 5 m. Data used for the modelling include water well logs, high-resolution seismic data, and a previously published 3D geological model. We apply a series of different strategies for the simulations based on data quality, and develop a novel method to effectively create observed sand/clay spatial trends. The training image is constructed as a small 3D voxel model covering an area of 90 km2. We use an iterative training image development strategy and find that even slight modifications in the training image create significant changes in simulations. Thus, the study underlines that it is important to consider both the geological environment, and the type and quality of input information in order to achieve optimal results from MPS modelling. In this study we present a possible workflow to build the training image and effectively handle different types of input information to perform large-scale geostatistical modellin
Complex Dynamics in Digital Nonlinear Oscillators: Experimental Analysis and Verification
A specific topology of Digital Nonlinear Oscillators (DNOs) has been implemented by using commercial off-the-shelf digital components to experimentally verify and demonstrate the capability of these circuits to support complex dynamics, independently from their implementation technology. In detail, a direct experimental evidence of the DNO dynamical behavior is presented at the analog level with a bifurcation diagram analysis, investigation of periodic and chaotic attractors, and dynamical stability. The autonomous circuit has been investigated as a source of entropy, adopting different figures of merit, including the Lempel–Ziv Complexity, to evaluate the dynamics measured under different operating conditions
Gas sensing properties of In2O3 nano-films obtained by low temperature pulsed electron deposition technique on alumina substrates
Nanostructured Indium(III) oxide (In2O3) films deposited by low temperature pulsed electron deposition (LPED) technique on customized alumina printed circuit boards have been manufactured and characterized as gas sensing devices. Their electrical properties have monitored directly during deposition to optimize their sensing performance. Experimental results with oxidizing (NO2) as well as reducing (CO) gases in both air and inert gas carriers are discussed and modeled
Strategies for the Accurate Measurement of the Resonance Frequency in QCM-D Systems via Low-Cost Digital Techniques
In this paper, an FPGA (Field Programmable Gate Array)-based digital architecture for the measurement of quartz crystal microbalance (QCM) oscillating frequency of transient responses, i.e., in QCM-D (QCM and Dissipation) applications, is presented. The measurement system is conceived for operations in liquid, with short QCM transient responses due to the large mechanical load. The proposed solution allows for avoiding the complex processing systems typically required by the QCM-D techniques and grants frequency resolutions better than 1 ppm. The core of the architecture is a reciprocal digital frequency meter, combined with the preprocessing of the QCM signal through mixing operations, such as a step-down of the input frequency and reducing the measurement error. The measurement error is further reduced through averaging. Different strategies are proposed to implement the proposed measurement solution, comprising an all-digital circuit and mixed analog/digital ones. The performance of the proposed architectures is theoretically derived, compared, and analyzed by means of experimental data obtained considering 10 MHz QCMs and 200 μs long transient responses. A frequency resolution of about 240 ppb, which corresponds to a Sauerbrey mass resolution of 8 ng/cm2, is obtained for the all-digital solution, whereas for the mixed solution the resolution halves to 120 ppb, with a measurement time of about one second over 100 repetitions
Probabilistic petrophysical reconstruction of Danta’s Alpine peatland via electromagnetic induction data
Peatlands are fundamental deposits of organic carbon. Thus, their protection is of crucial importance to avoid emissions from their degradation. Peat is a mixture of organic soil that originates from the accumulation of wetland plants under continuous or cyclical anaerobic conditions for long periods. Hence, a precise quantification of peat deposits is extremely important; for that, remote- and proximal-sensing techniques are excellent candidates. Unfortunately, remote-sensing can provide information only on the few shallowest centimeters, whereas peatlands often extend to several meters in depth. In addition, peatlands are usually characterized by difficult (flooded) terrains. So, frequency-domain electromagnetic instruments, as they are compact and contactless, seem to be the ideal solution for the quantitative assessment of the extension and geometry of peatlands. Generally, electromagnetic methods are used to infer the electrical resistivity of the subsurface. In turn, the resistivity distribution can, in principle, be interpreted to infer the morphology of the peatland. Here, to some extent, we show how to shortcut the process and include the expectation and uncertainty regarding the peat resistivity directly into a probabilistic inversion workflow. The present approach allows for retrieving what really matters: the spatial distribution of the probability of peat occurrence, rather than the mere electrical resistivity. To evaluate the efficiency and effectiveness of the proposed probabilistic approach, we compare the outcomes against the more traditional deterministic fully nonlinear (Occam's) inversion and against some boreholes available in the investigated area
Effects of combined Transcranial direct current stimulation with cognitive training in girls with Rett syndrome
Background: Transcranial Direct Current Stimulation (tDCS) combined with traditional rehabilitative techniques has not been widely applied to Rett Syndrome (RTT). The aim of this study was to examine the effects of combined cognitive traditional training with tDCS applied to attention and language measures in subjects with RTT. Methods: 31 subjects with RTT were randomly allocated into two groups: Non-sham tDCS (n = 18) and sham tDCS (n = 13). The former received the integrated intervention non-sham tDCS plus cognitive empowerment during the treatment phase. The latter received sham stimulation plus cognitive empowerment. All participants underwent neurological and cognitive assessment to evaluate attention and language measures: Before integrated treatment (pre-test phase), at the conclusion of the treatment (post-test phase), and at 1 month after the conclusion of the treatment (follow-up phase). Results: The results indicated longer attention time in the non-sham tDCS group compared to the sham tDCS group with a stable trend also in the follow-up phase; an increase of the number of vowel/phoneme sounds in the non-sham tDCS group; and an improvement in the neurophysiological parameters in the non-sham tDCS group. Conclusions: This study supports the use of tDCS as a promising and alternative approach in the RTT rehabilitation field
Advancing Thrombosis Research: A Novel Device for Measuring Clot Permeability
Thromboembolism, a global leading cause of mortality, needs accurate risk assessment for effective prophylaxis and treatment. Current stratification methods fall short in predicting thrombotic events, emphasizing the need for a deeper understanding of clot properties. Fibrin clot permeability, a crucial parameter in hypercoagulable states, impacts clot structure and resistance to lysis. Current clot permeability measurement limitations propel the need for standardized methods. Prior findings underscore the importance of clot permeability in various thrombotic conditions but call for improvements and more precise, repeatable, and standardized methods. Addressing these challenges, our study presents an upgraded, portable, and cost-effective system for measuring blood clot permeability, which utilizes a pressure-based approach that adheres to Darcy's law. By enhancing precision and sensitivity in discerning clot characteristics, this innovation provides a valuable tool for assessing thrombotic risk and associated pathological conditions. In this paper, the authors present a device that is able to automatically perform the permeability measurements on plasma or fibrinogen in vitro-induced clots on specific holders (filters). The proposed device has been tailored to distinguish clot permeability, with high precision and sensitivity, between healthy subjects and high cardiovascular-risk patients. The precise measure of clot permeability represents an excellent indicator of thrombotic risk, thus allowing the clinician, also on the basis of other anamnestic and laboratory data, to attribute a risk score to the subject. The proposed instrument was characterized by performing permeability measurements in plasma and purified fibrinogen clots derived from 17 Behcet patients and 15 sex- and age-matched controls. As expected, our results clearly indicate a significant difference in plasma clot permeability in Behcet patients with respect to controls (0.0533 +/- 0.0199 d vs. 0.0976 +/- 0.0160 d, p < 0.001). This difference was confirmed in the patient's vs. control fibrin clots (0.0487 +/- 0.0170 d vs. 0.1167 +/- 0.0487 d, p < 0.001). In conclusion, our study demonstrates the feasibility, efficacy, portability, and cost-effectiveness of a novel device for measuring clot permeability, allowing healthcare providers to better stratify thrombotic risk and tailor interventions, thereby improving patient outcomes and reducing healthcare costs, which could significantly improve the management of thromboembolic diseases
Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments
- …