47 research outputs found

    The clinical usefulness of routine stacked multiplanar reconstruction in helical abdominal computed tomography.

    No full text
    RATIONALE AND OBJECTIVES: The authors evaluate the usefulness of stacked multiplanar reconstructions in routine, thick-section abdominal computed tomography. MATERIALS AND METHODS: Twenty-five routine, thick-section contrast abdominal CTs performed with equivalent technique were reformatted by multiplanar reconstructions in sagittal and coronal planes sequentially from side-to-side and front-to-back. The image sets were submitted, first axial images only followed by axial plus multiplanar reconstructions (MPRs), to 5 separate physician readers including 2 radiologists and 3 nonradiologists. These readers graded the visualization of a variety of normal and up to 5 pathologic lesions per patient on a scale of 1 to 5 (5 = best). RESULTS: The addition of sagittal and coronal multiplanar reconstructions significantly improved the visualization of all normal anatomic structures (mean axial only, 3.8; mean axial plus MPR, 4.1; P \u3c 0.0001). In addition, most pathologic lesions were statistically better visualized with the addition of multiplanar reconstructions (mean axial images only, 3.9; mean axial plus MPR, 4.1; P \u3c 0.0001). All five readers found improved visualization in nearly every category with the addition of the multiplanar reconstructions. However, in only 7% of cases, did a reviewer find new diagnostic information with the addition of MPR images. CONCLUSIONS: Stacked multiplanar reconstructions of routine, thick-section abdominal CT has clinical value in both the display of normal anatomic and pathologic lesions. Further studies, however, are required to confirm these findings before it is commonly used

    PERFORMANCE OF THE ALEPH TIME PROJECTION CHAMBER

    No full text
    The performance of the ALEPH Time Projection Chamber (TPC) has been studied using data taken during the LEP running periods in 1989 and 1990. After correction of residual distortions and optimisation of coordinate reconstruction algorithms, single coordinate resolutions of 173-mu-m in the azimuthal and 740-mu-m in the longitudinal direction are achieved. This results in a momentum resolution for the TPC of DELTA-p/p2 = 1.2 x 10(-3) (GeV/c)-1. In combination with the ALEPH Inner Tracking Chamber (ITC), a total momentum resolution of DELTA-p/p2 = 0.8 x 10(-3) (GeV/c)-1 is obtained. With respect to particle identification, the detector achieves a resolution of 4.4% for the measurement of the ionisation energy loss
    corecore