992 research outputs found

    Dynamic percolation theory for particle diffusion in a polymer network

    Full text link
    Tracer-diffusion of small molecules through dense systems of chain polymers is studied within an athermal lattice model, where hard core interactions are taken into account by means of the site exclusion principle. An approximate mapping of this problem onto dynamic percolation theory is proposed. This method is shown to yield quantitative results for the tracer correlation factor of the molecules as a function of density and chain length provided the non-Poisson character of temporal renewals in the disorder configurations is properly taken into account

    What makes us human: revisiting an age-old question in the genomic era

    Get PDF
    In 1970, Karl Pribram took on the immense challenge of asking the question, what makes us human? Nearly four decades later, the most significant finding has been the undeniable realization of how incredibly subtle and fine-scaled the unique biological features of our species must be. The recent explosion in the availability of large-scale sequence data, however, and the consequent emergence of comparative genomics, are rapidly transforming the study of human evolution. The field of comparative genomics is allowing us to reach unparalleled resolution, reframing our questions in reference to DNA sequence – the very unit that evolution operates on. But like any reductionist approach, it comes at a price. Comparative genomics may provide the necessary resolution for identifying rare DNA sequence differences in a vast sea of conservation, but ultimately we will have to face the challenge of figuring out how DNA sequence divergence translates into phenotypic divergence. Our goal here is to provide a brief outline of the major findings made in the study of human brain evolution since the Pribram lecture, focusing specifically on the field of comparative genomics. We then discuss the broader implications of these findings and the future challenges that are in store

    Messing with the Normal Rate of Return: A Discussion

    Get PDF
    interest rate normal rate of return powerThoughts on 'objective value', power and the normal rate of return

    Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy.</p> <p>Methods</p> <p>In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1) determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2) discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments.</p> <p>Results</p> <p>Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters.</p> <p>Conclusion</p> <p>The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.</p
    • …
    corecore