216 research outputs found

    Mycolactone Diffuses into the Peripheral Blood of Buruli Ulcer Patients - Implications for Diagnosis and Disease Monitoring.

    Get PDF
    BACKGROUND: Mycobacterium ulcerans, the causative agent of Buruli ulcer (BU), is unique among human pathogens in its capacity to produce a polyketide-derived macrolide called mycolactone, making this molecule an attractive candidate target for diagnosis and disease monitoring. Whether mycolactone diffuses from ulcerated lesions in clinically accessible samples and is modulated by antibiotic therapy remained to be established. METHODOLOGY/PRINCIPAL FINDING: Peripheral blood and ulcer exudates were sampled from patients at various stages of antibiotic therapy in Ghana and Ivory Coast. Total lipids were extracted from serum, white cell pellets and ulcer exudates with organic solvents. The presence of mycolactone in these extracts was then analyzed by a recently published, field-friendly method using thin layer chromatography and fluorescence detection. This approach did not allow us to detect mycolactone accurately, because of a high background due to co-extracted human lipids. We thus used a previously established approach based on high performance liquid chromatography coupled to mass spectrometry. By this means, we could identify structurally intact mycolactone in ulcer exudates and serum of patients, and evaluate the impact of antibiotic treatment on the concentration of mycolactone. CONCLUSIONS/SIGNIFICANCE: Our study provides the proof of concept that assays based on mycolactone detection in serum and ulcer exudates can form the basis of BU diagnostic tests. However, the identification of mycolactone required a technology that is not compatible with field conditions and point-of-care assays for mycolactone detection remain to be worked out. Notably, we found mycolactone in ulcer exudates harvested at the end of antibiotic therapy, suggesting that the toxin is eliminated by BU patients at a slow rate. Our results also indicated that mycolactone titres in the serum may reflect a positive response to antibiotics, a possibility that it will be interesting to examine further through longitudinal studies

    CCQM-K90, formaldehyde in nitrogen, 2 ÎŒmol mol− 1 Final report

    Get PDF
    The CCQM-K90 comparison is designed to evaluate the level of comparability of national metrology institutes (NMI) or designated institutes (DI) measurement capabilities for formaldehyde in nitrogen at a nominal mole fraction of 2 ÎŒmol mol−1. The comparison was organised by the BIPM using a suite of gas mixtures prepared by a producer of specialty calibration gases. The BIPM assigned the formaldehyde mole fraction in the mixtures by comparison with primary mixtures generated dynamically by permeation coupled with continuous weighing in a magnetic suspension balance. The BIPM developed two dynamic sources of formaldehyde in nitrogen that provide two independent values of the formaldehyde mole fraction: the first one based on diffusion of trioxane followed by thermal conversion to formaldehyde, the second one based on permeation of formaldehyde from paraformaldehyde contained in a permeation tube. Two independent analytical methods, based on cavity ring down spectroscopy (CRDS) and Fourier transform infrared spectroscopy (FTIR) were used for the assignment procedure. Each participating institute was provided with one transfer standard and value assigned the formaldehyde mole fraction in the standard based on its own measurement capabilities. The stability of the formaldehyde mole fraction in transfer standards was deduced from repeated measurements performed at the BIPM before and after measurements performed at participating institutes. In addition, 5 control standards were kept at the BIPM for regular measurements during the course of the comparison. Temporal trends that approximately describe the linear decrease of the amount-of-substance fraction of formaldehyde in nitrogen in the transfer standards over time were estimated by two different mathematical treatments, the outcomes of which were proposed to participants. The two treatments also differed in the way measurement uncertainties arising from measurements performed at the BIPM were propagated to the uncertainty of the trend parameters, as well as how the dispersion of the dates when measurements were made by the participants was taken into account. Upon decision of the participants, the Key Comparison Reference Values were assigned by the BIPM using the largest uncertainty for measurements performed at the BIPM, linear regression without weight to calculate the trend parameters, and not taking into account the dispersion of dates for measurements made by the participant. Each transfer standard was assigned its own reference value and associated expanded uncertainty. An expression for the degree of equivalence between each participating institute and the KCRV was calculated from the comparison results and measurement uncertainties submitted by participating laboratories. Results of the alternative mathematical treatment are presented in annex of this report

    Antibody Response in Immunocompromised Patients After the Administration of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Vaccine BNT162b2 or mRNA-1273: A Randomized Controlled Trial

    Full text link
    BACKGROUND BNT162b2 by Pfizer-BioNTech and mRNA-1273 by Moderna are the most commonly used vaccines to prevent severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections. Head-to-head comparison of the efficacy of these vaccines in immunocompromised patients is lacking. METHODS Parallel, 2-arm (allocation 1:1), open-label, noninferiority randomized clinical trial nested into the Swiss HIV Cohort Study and the Swiss Transplant Cohort Study. People living with human immunodeficiency virus (PLWH) or solid organ transplant recipients (SOTR; ie, lung and kidney) from these cohorts were randomized to mRNA-1273 or BNT162b2. The primary endpoint was antibody response to SARS-CoV-2 spike (S1) protein receptor binding domain (Elecsys Anti-SARS-CoV-2 immunoassay, Roche; cutoff ≄0.8 units/mL) 12 weeks after first vaccination (ie, 8 weeks after second vaccination). In addition, antibody response was measured with the Antibody Coronavirus Assay 2 (ABCORA 2). RESULTS A total of 430 patients were randomized and 412 were included in the intention-to-treat analysis (341 PLWH and 71 SOTR). The percentage of patients showing an immune response was 92.1% (95% confidence interval [CI]: 88.4-95.8; 186/202) for mRNA-1273 and 94.3% (95% CI: 91.2-97.4; 198/210) for BNT162b2 (difference: -2.2%; 95% CI: -7.1 to 2.7), fulfilling noninferiority of mRNA-1273. With the ABCORA 2 test, 89.1% had an immune response to mRNA-1273 (95% CI: 84.8-93.4; 180/202) and 89.5% to BNT162b2 (95% CI: 85.4-93.7; 188/210). Based on the Elecsys test, all PLWH had an antibody response (100.0%; 341/341), whereas for SOTR, only 60.6% (95% CI: 49.2-71.9; 43/71) had titers above the cutoff level. CONCLUSIONS In immunocompromised patients, the antibody response of mRNA-1273 was noninferior to BNT162b2. PLWH had in general an antibody response, whereas a high proportion of SOTR had no antibody response

    Determinants of antibody response to severe acute respiratory syndrome coronavirus 2 mRNA vaccines in people with HIV.

    Get PDF
    We identified determinants of SARS-CoV-2 mRNA vaccine antibody response in people with HIV (PWH). Antibody response was higher among PWH less than 60 years, with CD4+ cell count superior to 350 cells/ÎŒl and vaccinated with mRNA-1273 by Moderna compared with BNT162b2 by Pfizer-BioNTech. Preinfection with SARS-CoV-2 boosted the antibody response and smokers had an overall lower antibody response. Elderly PWH and those with low CD4+ cell count should be prioritized for booster vaccinations

    Antibody response in immunocompromised patients after the administration of SARS-CoV-2 vaccine BNT162b2 or mRNA-1273: A randomised controlled trial.

    Get PDF
    BACKGROUND BNT162b2 by Pfizer-BioNTech and mRNA-1273 by Moderna are the most commonly used vaccines to prevent SARS-CoV-2 infections. Head-to-head comparison of the efficacy of these vaccines in immunocompromised patients is lacking. METHODS Parallel, two-arm (allocation 1:1), open-label, non-inferiority randomised clinical trial nested into the Swiss HIV Cohort Study and the Swiss Transplant Cohort Study. Patients living with HIV (PLWH) or solid organ transplant recipients (SOTR; i.e. lung and kidney) from these cohorts were randomised to mRNA-1273 or BNT162b2. The primary endpoint was antibody response to SARS-CoV-2 spike (S1) protein receptor binding domain (Elecsys Anti-SARS-CoV-2 immunoassay, Roche; cut-off ≄0.8 units/ml) 8 weeks after second vaccination. In addition, antibody response was measured with the Antibody CORonavirus Assay 2 (ABCORA 2). RESULTS 430 patients were randomised and 412 were included in the intention-to-treat analysis (341 PLWH and 71 SOTR). The percentage of patients showing an immune response was 92.1% (95% confidence interval [CI] 88.4-95.8%; 186/202) for mRNA-1273 and 94.3% (95% CI 91.2-97.4; 198/210) for BNT162b2 (difference: 2.2%; 95% CI -7.1 to 2.7), fulfilling non-inferiority of mRNA-1273. With the ABCORA 2 test 89.1% had an immune response to mRNA-1273 (95% CI 84.8-93.4%; 180/202) and 89.5% to BNT162b2 (95% CI 85.4-93.7%; 188/210). Based on the Elecsys test, all PLWH had an antibody response (100.0%; 341/341), while for SOTR only 60.6% (95% CI 49.2-71.9%; 43/71) had titres above the cut-off. CONCLUSIONS In immunocompromised patients the antibody response of mRNA-1273 was non-inferior to BNT162b2. PLWH had in general an antibody response, while a high proportion of SOTR had no antibody response

    Antibody Response After Third Vaccination With mRNA-1273 or BNT162b2: Extension of a Randomized Controlled SARS-CoV-2 Noninferiority Vaccine Trial in Patients With Different Levels of Immunosuppression (COVERALL-2).

    Get PDF
    Extension of the COVERALL (COrona VaccinE tRiAL pLatform) randomized trial showed noninferiority in antibody response of the third dose of Moderna mRNA-1273 vaccine (95.3% [95% confidence interval {CI}, 91.9%-98.7%]) compared to Pfizer-BioNTech BNT162b2 vaccine (98.1% [95% CI, 95.9%-100.0%]) in individuals with different levels of immunosuppression (difference, -2.8% [95% CI, -6.8% to 1.3%])

    Phylomemetics—Evolutionary Analysis beyond the Gene

    Get PDF
    Genes are propagated by error-prone copying, and the resulting variation provides the basis for phylogenetic reconstruction of evolutionary relationships. Horizontal gene transfer may be superimposed on a tree-like evolutionary pattern, with some relationships better depicted as networks. The copying of manuscripts by scribes is very similar to the replication of genes, and phylogenetic inference programs can be used directly for reconstructing the copying history of different versions of a manuscript text. Phylogenetic methods have also been used for some time to analyse the evolution of languages and the development of physical cultural artefacts. These studies can help to answer a range of anthropological questions. We propose the adoption of the term “phylomemetics” for phylogenetic analysis of reproducing non-genetic elements

    Antibody Response After the Third SARS-CoV-2 Vaccine in Solid Organ Transplant Recipients and People Living With HIV (COVERALL-2).

    Get PDF
    BACKGROUND After basic immunization with 2 mRNA SARS-CoV-2 vaccine doses, only a small proportion of patients who are severely immunocompromised generate a sufficient antibody response. Hence, we assessed the additional benefit of a third SARS-CoV-2 vaccine in patients with different levels of immunosuppression. METHODS In this observational extension of the COVERALL trial (Corona Vaccine Trial Platform), we recruited patients from the Swiss HIV Cohort Study and the Swiss Transplant Cohort Study (ie, lung and kidney transplant recipients). We collected blood samples before and 8 weeks after the third SARS-CoV-2 vaccination with either mRNA-1273 (Moderna) or BNT162b2 (Pfizer-BioNTech). The primary outcome was the proportion of participants showing an antibody response (Elecsys Anti-SARS-CoV-2 S test; threshold ≄100 U/mL) 8 weeks after the third SARS-CoV-2 vaccination. We also compared the proportion of patients who reached the primary outcome from basic immunization (the first and second vaccines) to the third vaccination. RESULTS Nearly all participants (97.2% [95% CI, 95.9%-98.6%], 564/580) had an antibody response. This response was comparable between mRNA-1273 (96.1% [95% CI, 93.7%-98.6%], 245/255) and BNT162b2 (98.2% [95% CI, 96.7%-99.6%], 319/325). Stratification by cohort showed that 99.8% (502/503) of people living with HIV and 80.5% (62/77) of recipients of solid organ transplants achieved the primary endpoint. The proportion of patients with an antibody response in solid organ transplant recipients improved from the second vaccination (22.7%, 15/66) to the third (80.5%, 62/77). CONCLUSIONS People living with HIV had a high antibody response. The third vaccine increased the proportion of solid organ transplant recipients with an antibody response. Clinical Trials Registration. NCT04805125 (ClinicalTrials.gov)

    Antibody and T-Cell Response to Bivalent Booster SARS-CoV-2 Vaccines in People With Compromised Immune Function: COVERALL-3 Study

    Get PDF
    Background Bivalent messenger RNA (mRNA) vaccines, designed to combat emerging severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants, incorporate ancestral strains and a new variant. Our study assessed the immune response in previously vaccinated individuals of the Swiss HIV Cohort Study (SHCS) and the Swiss Transplant Cohort Study (STCS) following bivalent mRNA vaccination. Methods Eligible SHCS and STCS participants received approved bivalent mRNA SARS-CoV-2 vaccines (mRNA-1273.214 or BA.1-adapted BNT162b2) within clinical routine. Blood samples were collected at baseline, 4 weeks, 8 weeks, and 6 months postvaccination. We analyzed the proportion of participants with anti-spike protein antibody response ≄1642 units/mL (indicating protection against SARS-CoV-2 infection), and in a subsample T-cell response (including mean concentrations), stratifying results by cohorts and population characteristics. Results In SHCS participants, baseline anti-spike antibody concentrations ≄1642 units/mL were observed in 87% (96/112), reaching nearly 100% at follow-ups. Among STCS participants, 58% (35/60) had baseline antibodies ≄1642 units/mL, increasing to 80% at 6 months. Except for lung transplant recipients, all participants showed a 5-fold increase in geometric mean antibody concentrations at 4 weeks and a reduction by half at 6 months. At baseline, T-cell responses were positive in 96% (26/27) of SHCS participants and 36% (16/45) of STCS participants (moderate increase to 53% at 6 months). Few participants reported SARS-CoV-2 infections, side-effects, or serious adverse events. Conclusions Bivalent mRNA vaccination elicited a robust humoral response in individuals with human immunodeficiency virus (HIV) or solid organ transplants, with delayed responses in lung transplant recipients. Despite a waning effect, antibody levels remained high at 6 months and adverse events were rare. Clinical Trials Registration . NCT04805125
    • 

    corecore