22 research outputs found

    Independent individual addressing of multiple neutral atom qubits with a MEMS beam steering system

    Full text link
    We demonstrate a scalable approach to addressing multiple atomic qubits for use in quantum information processing. Individually trapped 87Rb atoms in a linear array are selectively manipulated with a single laser guided by a MEMS beam steering system. Single qubit oscillations are shown on multiple sites at frequencies of ~3.5 MHz with negligible crosstalk to neighboring sites. Switching times between the central atom and its closest neighbor were measured to be 6-7 us while moving between the central atom and an atom two trap sites away took 10-14 us.Comment: 9 pages, 3 figure

    Cost-effectiveness analysis of 3-D computerized tomography colonography versus optical colonoscopy for imaging symptomatic gastroenterology patients.

    No full text
    BACKGROUND: When symptomatic gastroenterology patients have an indication for colonic imaging, clinicians have a choice between optical colonoscopy (OC) and computerized tomography colonography with three-dimensional reconstruction (3-D CTC). 3-D CTC provides a minimally invasive and rapid evaluation of the entire colon, and it can be an efficient modality for diagnosing symptoms. It allows for a more targeted use of OC, which is associated with a higher risk of major adverse events and higher procedural costs. A case can be made for 3-D CTC as a primary test for colonic imaging followed if necessary by targeted therapeutic OC; however, the relative long-term costs and benefits of introducing 3-D CTC as a first-line investigation are unknown. AIM: The aim of this study was to assess the cost effectiveness of 3-D CTC versus OC for colonic imaging of symptomatic gastroenterology patients in the UK NHS. METHODS: We used a Markov model to follow a cohort of 100,000 symptomatic gastroenterology patients, aged 50 years or older, and estimate the expected lifetime outcomes, life years (LYs) and quality-adjusted life years (QALYs), and costs (£, 2010-2011) associated with 3-D CTC and OC. Sensitivity analyses were performed to assess the robustness of the base-case cost-effectiveness results to variation in input parameters and methodological assumptions. RESULTS: 3D-CTC provided a similar number of LYs (7.737 vs 7.739) and QALYs (7.013 vs 7.018) per individual compared with OC, and it was associated with substantially lower mean costs per patient (£467 vs £583), leading to a positive incremental net benefit. After accounting for the overall uncertainty, the probability of 3-D CTC being cost effective was around 60 %, at typical willingness-to-pay values of £20,000-£30,000 per QALY gained. CONCLUSION: 3-D CTC is a cost-saving and cost-effective option for colonic imaging of symptomatic gastroenterology patients compared with OC

    Scalable Architecture for a Room Temperature Solid-State Quantum Information Processor

    Get PDF
    The realization of a scalable quantum information processor has emerged over the past decade as one of the central challenges at the interface of fundamental science and engineering. Much progress has been made towards this goal. Indeed, quantum operations have been demonstrated on several trapped ion qubits, and other solid-state systems are approaching similar levels of control. Extending these techniques to achieve fault-tolerant operations in larger systems with more qubits remains an extremely challenging goal, in part, due to the substantial technical complexity of current implementations. Here, we propose and analyze an architecture for a scalable, solid-state quantum information processor capable of operating at or near room temperature. The architecture is applicable to realistic conditions, which include disorder and relevant decoherence mechanisms, and includes a hierarchy of control at successive length scales. Our approach is based upon recent experimental advances involving Nitrogen-Vacancy color centers in diamond and will provide fundamental insights into the physics of non-equilibrium many-body quantum systems. Additionally, the proposed architecture may greatly alleviate the stringent constraints, currently limiting the realization of scalable quantum processors.Comment: 15 pages, 6 figure

    Ion-trap quantum information processing: experimental status

    Full text link
    Atomic ions trapped in ultra-high vacuum form an especially well-understood and useful physical system for quantum information processing. They provide excellent shielding of quantum information from environmental noise, while strong, well-controlled laser interactions readily provide quantum logic gates. A number of basic quantum information protocols have been demonstrated with trapped ions. Much current work aims at the construction of large-scale ion-trap quantum computers using complex microfabricated trap arrays. Several groups are also actively pursuing quantum interfacing of trapped ions with photons.Comment: review article for Frontiers of Physics replace corrupted TeX fil

    Influence Of Corrosion On Lipopolysaccharide Affinity For Two Different Titanium Materials.

    No full text
    Titanium is subject to corrosion in the oral cavity, which could contribute to periimplantitis. However, the effect of corrosion on the lipopolysaccharide affinity for titanium remains unknown. This study evaluated the role of corrosion (in artificial saliva at pHs 3, 6.5, and 9) on the lipopolysaccharide (LPS) affinity for commercially pure titanium (cp-Ti) and Ti-6Al-4V alloy. Seventy-two titanium disks were anodically polarized in a controlled environment (n=9). Control specimens were not corroded. Deionized water with different concentrations of LPS (1.5, 15, and 150 μg/mL) were used to treat the disks for 24 hours to investigate LPS adherence (n=3). Then specimens were immersed in LPS-free water to evaluate LPS elution at 24, 48, and 72 hours. Data were analyzed by the 2-way, 3-way, and 3-way repeated measures ANOVA, t tests, and the Tukey honestly significant difference (HSD) tests (α=.05). A greater corrosion rate of cp-Ti and Ti-6Al-4V alloy and a higher LPS adherence to titanium surfaces (P<.05) were noted at acidic pH. The LPS affinity was higher for the Ti-6Al-4V alloy than for cp-Ti (P<.05). More LPS was eluted from titanium surfaces after a 24-hour interval. Lipopolysaccharide affinity for cp-Ti and Ti-6Al-4V alloy is influenced by the corrosion process.110462-7

    Microstructural and mechanical characterization of contemporary lingual orthodontic brackets

    Get PDF
    Objectives:To investigate the composition and the microstructural and mechanical characterization of three different types of lingual brackets.Materials and Methods:Incognito™ (3M Unitek), In-Ovation L (DENTSPLY GAC) and STb™ (Light Lingual System, ORMCO) lingual brackets were studied under the scanning electron microscope employing backscattered electron imaging and their elemental composition was analysed by energy-dispersive X-ray microanalysis. Additionally, Vickers hardness was assessed using a universal hardness-testing machine, and the indentation modulus was measured according to instrumented indentation test. Two-way analysis of variance was conducted employing bracket type and location (base and wing) as discriminating variable. Significant differences among groups were allocated by post hoc Student-Newman-Keuls multiple comparison analysis at 95% level of significance.Results:Three different phases were identified for Incognito and In-Ovation L bracket based on mean atomic number contrast. On the contrary, STb did not show mean atomic contrast areas and thus it is recognized as a single phase. Incognito is a one-piece bracket with the same structure in wing and base regions. Incognito consists mainly of noble metals while In-Ovation L and STb show similar formulations of ferrous alloys in wing and base regions. No significant differences were found between ferrous brackets in hardness and modulus values, but there were significant differences between wing and base regions. Incognito illustrated intermediate values with significant differences from base and wing values of ferrous brackets.Conclusions/Implications:Significant differences exist in microstructure, elemental composition, and mechanical properties among the brackets tested; these might have a series of clinical implications during mechanotherapy

    Influence of corrosion on lipopolysaccharide affinity for two different titanium materials

    No full text
    Titanium is subject to corrosion in the oral cavity, which could contribute to periimplantitis. However, the effect of corrosion on the lipopolysaccharide affinity for titanium remains unknown. This study evaluated the role of corrosion (in artificial saliva at pHs 3, 6.5, and 9) on the lipopolysaccharide (LPS) affinity for commercially pure titanium (cp-Ti) and Ti-6Al-4V alloy. Seventy-two titanium disks were anodically polarized in a controlled environment (n=9). Control specimens were not corroded. Deionized water with different concentrations of LPS (1.5, 15, and 150 μg/mL) were used to treat the disks for 24 hours to investigate LPS adherence (n=3). Then specimens were immersed in LPS-free water to evaluate LPS elution at 24, 48, and 72 hours. Data were analyzed by the 2-way, 3-way, and 3-way repeated measures ANOVA, t tests, and the Tukey honestly significant difference (HSD) tests (α=.05). A greater corrosion rate of cp-Ti and Ti-6Al-4V alloy and a higher LPS adherence to titanium surfaces (P<.05) were noted at acidic pH. The LPS affinity was higher for the Ti-6Al-4V alloy than for cp-Ti (P<.05). More LPS was eluted from titanium surfaces after a 24-hour interval. Lipopolysaccharide affinity for cp-Ti and Ti-6Al-4V alloy is influenced by the corrosion process.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES
    corecore